Rhizome

Hepatic and Renal Impairment PK Studies: FDA and EMA Design Expectations and Label Dosing Outcomes

Chetan Mishra
Chetan Mishra
Published Nov 17, 2026 · Updated Nov 23, 2026

Organ impairment pharmacokinetic studies decide whether a drug needs dose adjustment, a contraindication or only a labeling statement for patients with reduced liver or kidney function. FDA and EMA expect sponsors to decide early whether a dedicated study is needed, how to stratify impairment, and how to turn exposure changes into dosing advice. FDA's hepatic guidance is now under revision, so teams planning clinical pharmacology programs need to know where the two agencies agree and where they differ.

The analysis below covers the current FDA and EMA guidance on renal and hepatic impairment studies. It explains when a dedicated study is triggered, which reduced and full study designs are acceptable, how impairment is classified, and how data analysis should feed labeling. It then reviews recent US drug labels to show the range of dosing recommendations these studies have produced.

Rhizome is an AI regulatory coworker that researches 143 health authority databases, and cites a specific page for each claim. Create a free account to ask it questions or have your agents search its databases.Connect it to your Claude or ChatGPT for free to ask it questions or have your agents search its databases.

Hepatic and renal impairment PK studies: FDA and EMA design expectations and recent label dosing outcomes

Key takeaways

  • The renal guidance is current on both sides of the Atlantic. FDA finalized Pharmacokinetics in Patients with Impaired Renal Function: Study Design, Data Analysis, and Impact on Dosing on March 15, 2024 172. EMA's Guideline on the evaluation of the pharmacokinetics of medicinal products in patients with decreased renal function (EMA/CHMP/83874/2014) was adopted by CHMP on 17 December 2015 and took effect on 1 July 2016 23.
  • Hepatic guidance is in flux at FDA. FDA issued a draft revision, Pharmacokinetics in Patients with Impaired Hepatic Function: Study Design, Data Analysis, and Impact on Dosage, on September 2, 2026 244. The May 2003 guidance it replaces, Pharmacokinetics in Patients with Impaired Hepatic Function: Study Design, Data Analysis, and Impact on Dosing and Labeling, has been withdrawn 253. EMA's hepatic guideline (CPMP/EWP/2339/02) dates from August 2005 9293.
  • Both agencies use the same basic logic. A dedicated study is usually triggered when the relevant organ eliminates a meaningful share of the drug, or when impairment is otherwise likely to change exposure enough to affect dosing. Reduced "worst-case" designs are acceptable for screening. Dosing advice should come from exposure-response, not from the size of the PK change alone.
  • Recent US labels show the full range of outcomes. Examples include stepwise eGFR-based regimens for renally cleared anti-infectives (UTEBZI, ZAYNICH) 155156157161162163164, a fixed lower dose in moderate-to-severe hepatic impairment (INLURIYO) 227, a tapered moderate-hepatic regimen (JOURNAVX) 230, and "not recommended" or contraindicated statements where exposure increases are large (COBENFY) 383416.

Governing documents

TopicFDAEMA
Renal impairmentFinal guidance, March 15, 2024 172Guideline EMA/CHMP/83874/2014, adopted 17 December 2015, effective 1 July 2016 23
Hepatic impairmentDraft guidance, September 2, 2026 (not for implementation) 244252Guideline CPMP/EWP/2339/02, August 2005 9293

Renal impairment studies

When a dedicated study is expected

FDA. A dedicated study is recommended when renal impairment is likely to alter the PK of the drug or its active metabolites because they are substantially renally eliminated. FDA defines "substantially" as at least 30% of the systemically available drug or active metabolite excreted unchanged in urine 355. A full PK design is recommended for this category 178. For drugs cleared mainly by non-renal routes, an effect of severe renal impairment cannot always be excluded, so a reduced study should be considered 356. Therapeutic proteins above 69 kDa are listed among products for which a dedicated study may not be warranted 357.

EMA. A study should be conducted for primarily renally eliminated drugs unless otherwise justified. A study is also recommended for primarily hepatically eliminated drugs, because renal impairment can change exposure through non-renal mechanisms 41. The guideline gives examples of justified exceptions, each requiring justification. These include single or occasional administration without safety concerns, large proteins not expected to be filtered, no relevant systemic absorption, and drugs not indicated in renal impairment 29. EMA also asks sponsors to consider studying renal impairment before the pivotal trial when specific treatment recommendations are likely, so that these patients can be included and appropriately dosed 4344.

Study design

ElementFDA (2024)EMA (2016)
Full designRenal function from normal through severe impairment or kidney failure not on dialysis 180Full range, including ESRD where feasible. About 6 to 8 subjects per group is usually sufficient, but coverage across GFR matters more than equal group sizes. Include subjects at 20 mL/min or below 46
Reduced designSevere impairment or kidney failure not on dialysis versus normal function. If no PK difference, no further study. If a clinically relevant effect, characterize the other levels 183184Worst-case group, preferably GFR 20 mL/min or below without dialysis, versus controls 4748. Staged expansion if effects at other levels cannot be excluded 4749
Sample sizeJustified for precise estimation. Example: 95% CI within 60% to 140% of the geometric mean with at least 80% power 182Prospectively define clinical relevance and justify the decision criteria, confidence intervals and significance level for reduced studies 50
Population and controlsStable renal function, groups similar on PK-relevant factors, exclude interacting comedications 181Chronic or stable renal disease, groups comparable on age, sex, weight and pharmacogenetics 51. Control group reflects the renal function typical of the pivotal trial population, not necessarily normal function 52

Measuring and classifying renal function

FDA recommends eGFR over estimated creatinine clearance because of its availability and clinical use, while still accepting measured GFR, measured CLcr or a contemporary validated equation 185. Adult dosing recommendations should use absolute eGFR in mL/min (indexed eGFR multiplied by BSA/1.73), not mL/min/1.73 m² 186. When Cockcroft-Gault is used in overweight or obese individuals, ideal or adjusted body weight is likely to be more accurate than actual weight 187. One estimation method should be used across groups and pooled studies 188189.

EMA prefers measured GFR using an exogenous marker where possible, particularly when a narrow therapeutic index makes a dosing cut-off critical 53. It notes that creatinine clearance may overestimate GFR because creatinine is also secreted 54. Dosing should also be based on absolute renal function in mL/min 55.

CategoryFDA Table 1 (dedicated studies only)EMA Table 1
Normal or control≥90 mL/min 191≥90 mL/min 56
Mild60 to <90 19260 to <90 57
Moderate30 to <60 19330 to <60 58
Severe<30, including kidney failure not on dialysis 194<30, not requiring dialysis 59
ESRDIncluded in the <30 category if not on dialysis 194<15, requiring dialysis 60

FDA states these categories are strictly for dedicated renal impairment studies, not for classifying kidney disease 195.

Dialysis and renal replacement therapy

FDA expects intermittent hemodialysis studies to include on- and off-dialysis periods, with dialysis typically started just before the anticipated Tmax 197. They should use high-flux dialysis, and blood flow, dialysate flow, ultrafiltration and dialyzer model should be recorded 198. Dialysis clearance is calculated as the amount recovered in dialysate divided by AUC over the session 205. For drugs likely to be used in critically ill patients, FDA recommends evaluating CRRT separately because hemodialysis findings may not extrapolate 199.

EMA similarly calls for dosing before and after dialysis. It warns that extrapolation between modalities can be misleading 6364. A dialysis study is unnecessary when high protein binding, a large volume of distribution or high non-renal clearance make removal unlikely 65.

Population PK as a supplement or alternative

Both agencies accept population PK from phase 2/3 trials when renal function is well represented. FDA states such analyses may suffice for the population represented, but a reduced study may still be needed if severe impairment is under-represented 179. FDA lists the design elements needed: participants across a wide renal function range, accurate dosing and sampling times, unbound concentrations when appropriate, and active metabolite measurements 201. EMA is more cautious. It notes that severe impairment and ESRD are commonly under-represented in phase 2/3 data and recommends a phase 1 full or reduced study when renal evaluation is indicated 67. EMA also states that population models must not be extrapolated outside the studied renal function range 69.

From PK data to dosing recommendations

FDA bases dosing on the relationship among renal function, exposure and exposure-response. A PK change does not necessarily require a different dose, especially for drugs with a wide therapeutic range 401. Where adjustment is needed, FDA recommends exposure-matching to a reference group with acceptable benefit-risk, which need not have normal renal function 401. Supporting approaches include simulations targeting the 5th to 95th percentile of reference exposure, or predefined no-effect boundaries 402. Modeling should identify the renal function level at which dosing changes, rather than defaulting to study categories 403.

EMA takes the same view: dose-adjustment cut-offs need not match the 30, 60 and 90 mL/min recruitment boundaries 73. It asks for steady-state simulations showing target attainment just above and below each cut-off 74. For active metabolites, recommendations should reflect the total active moiety, accounting for potency and unbound exposure 73.

Labeling and SmPC expectations

FDA's Prescribing Information should summarize PK and PD (including in dialysis), renal elimination of the drug and active metabolites, clinical effects of the PK changes, and risk-mitigation measures such as dose or monitoring changes 405406407408409. EMA asks for specific dosing advice in SmPC section 4.2, including an explicit statement when no adjustment is needed. If creatinine clearance rather than GFR was used in the PK study, the SmPC should say so 75. EMA states that lack of data alone should generally not lead to a contraindication without a specific safety concern 76.

Hepatic impairment studies

When a dedicated study is expected

FDA's 2026 draft recommends a dedicated hepatic impairment study if any of these apply 319:

  • Hepatic metabolism and/or excretion accounts for more than 30% of elimination of the absorbed parent drug or active metabolites 320.
  • Small concentration changes could be clinically significant 321.
  • Elimination pathways are not adequately characterized 322.
  • The drug treats liver disease 323.
  • The drug is likely to be used in patients with hepatic impairment 324.

A study may not be warranted for these products: drugs with less than 30% hepatic elimination and no narrow-margin concerns 326, drugs entirely renally excreted 327, single-administration products 328, locally acting products with limited systemic exposure 329, and volatile drugs eliminated through the lungs 330.

EMA recommends a study when all three of these conditions hold: the drug is likely to be used in hepatic impairment, impairment is likely to significantly alter PK, and dose adjustment may be needed given the PK/PD relationship 94. If no study is performed, the sponsor must justify the omission. Missing data may lead to restrictions, including contraindications 95.

Study design

ElementFDA draft (2026)EMA (2005)
GroupsMild, moderate and severe impairment plus controls. Studying severe impairment first may be reasonable, with the other groups added if a significant effect is seen 295296Moderate impairment versus healthy controls is an acceptable screening design. If a significant effect is found, study milder and, if possible, more severe impairment 9798
ControlsSimilar in age, sex, race or ethnicity, weight and relevant polymorphic enzyme or transporter phenotypes 268Within-study normal-function controls matched on PK determinants. Historical controls are discouraged 104
SubjectsRecord liver disease etiology. Exclude acute or acute-on-chronic disease. Laboratory values and clinical status should be stable before dosing 297298Volunteers with hepatic disease are acceptable when studying patients with the intended indication is impractical 97
DosingSingle dose if PK is dose-proportional and time-independent. Otherwise multiple doses, preferably to steady state. A lower dose may be appropriate if higher concentrations would be dose-limiting 303304Single dose for linear, time-independent PK. Multiple dosing for nonlinear or time-dependent PK. Consider a lower dose for drugs with high first-pass metabolism 99100
Sample sizeExample target: 95% CI within 60% to 140% of the geometric mean with at least 80% power 301302Sized to detect a prespecified, justified clinically relevant difference 98

Classification of hepatic impairment

Both agencies use Child-Pugh: class A (score 5 to 6, mild), class B (7 to 9, moderate) and class C (10 to 15, severe) 254101. FDA asks for both total and component scores, including how ascites and encephalopathy were assessed (for example, with or without diuretics) 256. FDA's draft allows NCI criteria in oncology but recommends Child-Pugh for hepatobiliary cancers and does not recommend NCI criteria in non-cancer patients 299300. EMA notes that Child-Pugh was not developed to predict drug elimination capacity and that even normal hepatic function scores 5 101102.

Unbound concentrations

FDA's draft is more prescriptive than EMA on protein binding. For high-extraction drugs (extraction ratio >0.7) with extensive binding (fraction unbound <10%), the unbound fraction should be determined at trough and peak 306. FDA encourages the same approach for low-extraction (<0.3), highly bound drugs 307. Any decision not to measure unbound concentrations should be explained, and samples should be archived for drugs that are not extensively bound 308. EMA asks that unbound parent and active metabolite concentrations be analysed for highly protein-bound drugs 105.

Analysis, dose development and labeling

FDA asks for impaired-to-control geometric mean ratios with 90% confidence intervals for total and unbound AUC and Cmax 261. It also asks for exploration of PK relationships with individual Child-Pugh components 262. The dose-development framework mirrors the renal guidance. The usual dose may be retained if exposure changes are not clinically significant. Otherwise, exposure-matching to a reference group should be used, supported by 5th to 95th percentile simulations or no-effect boundaries 474475476477478. Population PK may suffice if hepatic impairment is adequately represented in trials, with a dedicated study filling gaps 456457. Labeling should cover PK/PD in hepatic impairment, hepatic elimination, clinical effects and risk-mitigation measures 468469470471472.

EMA asks for prespecified, justified PK changes that warrant dose adjustment 108. Simulations may help identify doses and intervals meeting targets 109. In SmPC section 4.2, sponsors should describe the studied subjects and not extrapolate beyond them, stating explicitly when no adjustment is needed 110. Section 5.2 should describe the hepatic disease studied and state if hepatic impairment was not evaluated. A claim of no clinically relevant effect requires good justification 112.

FDA and EMA at a glance

IssueFDAEMA
Renal trigger≥30% excreted unchanged in urine 355Primarily renal elimination, and also recommended for primarily hepatic elimination 41
Hepatic trigger>30% hepatic elimination, or any of four other criteria 320319All three conditions: likely use, likely PK change, possible dose adjustment 94
Reduced renal design anchorSevere impairment or kidney failure not on dialysis 183GFR ≤20 mL/min, not on dialysis 48
Reduced hepatic design anchorSevere impairment first, in certain cases 296Moderate impairment screening 97
Renal function metriceGFR preferred, absolute mL/min 185186Measured GFR preferred where critical, absolute mL/min 5355
Renal control groupNormal renal function 191Renal function typical of the pivotal population 52
Dose-adjustment cut-offsDerived by modeling, not tied to study categories 403Need not equal the 30/60/90 mL/min boundaries 73

How recent US labels translate PK findings into dosing

The labels below are from recent new molecular entity approvals in Drugs@FDA. They show how the exposure-response principles in the guidances play out in practice.

Hepatic impairment

ProductPK findingLabeled recommendation
INLURIYO (imlunestrant)AUC 2.2-fold higher in Child-Pugh B and 3.1-fold higher in Child-Pugh C. No clinically significant change in Child-Pugh A 422200 mg once daily in moderate or severe impairment, with monitoring for adverse reactions 227. No modification in mild impairment 423
JOURNAVX (suzetrigine)Child-Pugh B: steady-state AUC0-12h 1.5-fold higher (90% CI 1.1 to 2.1), Cmax 1.3-fold higher. Child-Pugh C effect unknown 390Moderate impairment: 100 mg first dose, then 50 mg every 12 hours for doses 2 to 4, then 50 mg every 24 hours 230. Avoid in severe impairment 231. Mild impairment: same as normal 229
BLUJEPA (gepotidacin)Child-Pugh C: AUC about 1.7-fold and Cmax about 1.9-fold higher 366No adjustment in Child-Pugh A/B 369. Avoid in Child-Pugh C because of increased exposure and QTc prolongation risk 368
COBENFY (xanomeline/trospium)Xanomeline Cmax 2.8-fold and AUC 2.6-fold higher in Child-Pugh A, and at least 7-fold higher in Child-Pugh B. Trospium exposure not substantially affected 377Not recommended in mild impairment 382. Contraindicated in moderate or severe impairment 383
LISRAYA (brepocitinib)Severe impairment not evaluated 233Same dosage in Child-Pugh A/B. Not recommended in Child-Pugh C 233
NEREUS (tradipitant)Not studied in any degree of hepatic impairment 235Avoid use in Child-Pugh A to C 235
LIVDELZI (seladelpar), IQIRVO (elafibranor)Liver-disease indicationsMonitor patients with cirrhosis for decompensation. Consider discontinuation if they progress to Child-Pugh B/C 240242

Renal impairment

ProductPK findingLabeled recommendation
UTEBZI (tebipenem pivoxil)Dose-normalized AUC0-inf higher than at eGFR ≥90 (MDRD): 1.4-fold at eGFR 60 to <90, 2.2-fold at 30 to 59, 4.5-fold at 15 to 29, and 7.2-fold at <15 or on hemodialysis 431432433434435. About 40% of a 600 mg dose removed by 4-hour hemodialysis 429600 mg every 6 hours (eGFR 60 to <90), 300 mg every 6 hours (30 to 59), 300 mg every 12 hours (15 to 29) 155156157. Insufficient data for hemodialysis 159. Not recommended at eGFR >150 mL/min because of predicted lower exposure 443
ZAYNICH (cefepime/zidebactam)AUC fold increases versus CrCl ≥90 (Cockcroft-Gault) for cefepime and zidebactam: 3.0 and 3.3 at CrCl 30 to 59, 4.2 and 5.4 at 15 to 29, and 9.9 and 16.0 in ESRD on hemodialysis 3123153163173 g every 8 hours (eGFR 60 to 89), 1.5 g every 8 hours (30 to 59), 1.5 g every 12 hours (15 to 29), and 1.5 g every 24 hours (8 to 14, with or without intermittent hemodialysis) 161162163164
COBENFY (xanomeline/trospium)Steady-state xanomeline AUC 1.9, 2.1 and 2.4-fold higher, and trospium AUC 1.6, 2.2 and 2.9-fold higher, in mild, moderate and severe impairment 412Mild: same as normal 414. Not recommended at eGFR <60 mL/min 416
DATROWAY (datopotamab deruxtecan)No clinically significant PK differences at CLcr 30 to <90 mL/min. Severe impairment effect unknown 167168No dose adjustment at CLcr 30 to <90 mL/min, but monitor for increased adverse reactions, including ILD/pneumonitis 166
LISRAYA (brepocitinib)Parent AUC 48% higher in moderate impairment. Metabolite M1 AUC up to 346% higher in severe impairment (eGFR 15 to 29) 171266Same dosage in mild or moderate impairment. Not recommended at eGFR <30

Patterns in the recent labels

  • Fold-changes alone do not set the dose. BLUJEPA's 1.7-fold AUC increase in severe hepatic impairment led to "avoid use" because of QTc risk 368. JOURNAVX's 1.5-fold increase in moderate impairment led to a tapered regimen rather than a simple dose cut 390230. Both outcomes illustrate the exposure-response approach both agencies' guidance recommends 401108.
  • Renally cleared anti-infectives get stepwise eGFR tables. The UTEBZI and ZAYNICH dose steps track the graded AUC increases by renal function band 431432433155156157315316163. ZAYNICH extends the table to eGFR 8 to 14 mL/min with or without hemodialysis 164.
  • Large measured exposure increases, or absent data, can lead to restriction rather than dose adjustment. COBENFY's at least 7-fold xanomeline increase in moderate hepatic impairment led to a contraindication 377383. NEREUS, with no hepatic data at all, is labeled "avoid use" across all Child-Pugh classes 235.
  • Labels flag where data stop. UTEBZI states that data are insufficient for hemodialysis 159. DATROWAY states that the effect of severe renal impairment is unknown 168. This matches FDA's expectation that labeling convey what was and was not characterized 405, and EMA's instruction not to extrapolate beyond the studied population 110.
Rhizome is an AI regulatory coworker that researches 143 health authority databases, and cites a specific page for each claim. Create a free account to ask it questions or have your agents search its databases.Connect it to your Claude or ChatGPT for free to ask it questions or have your agents search its databases.