Rhizome

Drug-Induced Phospholipidosis in FDA and EMA Reviews: Nonclinical Assessment, Development Impact and Labeling

Chetan Mishra
Chetan Mishra
Nov 1, 2026

Phospholipidosis is a common repeat-dose toxicology finding for cationic amphiphilic drugs. It can come up at any point from IND-enabling studies to marketing authorization. Teams need to know how health authorities weigh it against associated pathology, exposure margins and reversibility. That judgment shapes study design, clinical monitoring plans and the safety narrative in a submission.

The analysis below draws on public FDA review documents and EMA assessment reports for new drugs. It looks at how reviewers judged whether phospholipidosis findings were adverse and relevant to humans. It also identifies cases where the findings led to a partial clinical hold, additional nonclinical studies, targeted clinical monitoring, postmarketing commitments, risk management plan entries or labeling text.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.

Drug-induced phospholipidosis in FDA and EMA reviews: assessment, development impact and labeling

Drug-induced phospholipidosis (PLD), the lysosomal accumulation of phospholipid seen as foamy macrophages, vacuolated cells or lamellar bodies, is a common repeat-dose toxicology finding for cationic amphiphilic drugs. FDA and EMA review documents show a consistent pattern. On its own, PLD is rarely treated as a barrier to approval. Reviewers judge it on the company it keeps: associated tissue injury or functional effects, exposure margins, reversibility, the clinical dosing regimen, and whether a plausible clinical correlate exists. When those factors are unfavorable, the finding has led to a partial clinical hold, additional animal studies, targeted clinical monitoring, postmarketing commitments, EU risk management plan (RMP) entries and, most commonly, nonclinical labeling text.

Key takeaways

  • Default position: "human significance unknown." Both agencies usually conclude that the relevance of animal PLD to humans is unknown or unclear. Examples include adagrasib 11501148, pimavanserin 1239, vorapaxar in the EU 1077, relugolix 7171062 and bedaquiline in the EU SmPC 897.
  • The adverse/nonadverse line is drawn on associated pathology, not on PLD itself. For cariprazine, FDA pathology experts considered foamy macrophages alone adaptive and nonadverse at about 2.2 times human exposure, but active lung inflammation adverse at about 4.2 times 1123. For adagrasib, FDA considered PLD adverse only where it was associated with deaths and lung, cardiac, splenic or reproductive toxicity 11501151.
  • Labeling is the most frequent consequence. In the US, PLD appears in Section 13.2 (Animal Toxicology and/or Pharmacology) for products such as Nuplazid, Brexafemme, Krazati, Orgovyx, Myfembree, Sirturo and Vraylar 12387011153718106213461255. In the EU, it appears in SmPC section 5.3 (Preclinical safety data) 8477958971082563783881.
  • Development requirements followed when margins were thin, the finding was progressive or lung function was at stake. Lomitapide is the clearest example: a partial clinical hold from 2007 to 2010 on trials longer than six months 10161371.
  • Clinical PLD is labeled as a clinical risk only where it has been documented in patients. Hydroxychloroquine's Warnings and Precautions link biopsy-proven PLD to cardiomyopathy, myopathy/neuropathy and renal injury 129412961297. Amiodarone labeling treats foamy macrophages as "markers of therapy" rather than evidence of toxicity 12181219.

How reviewers characterize a phospholipidosis finding

Across both agencies, review documents assess PLD along the same set of variables.

Species, tissue distribution and confirmation

Reviewers record which species and organs are affected and whether PLD was confirmed ultrastructurally. Pimavanserin produced multi-system PLD in mice, rats and monkeys, prominently in rat lung and kidney 767768769. Bedaquiline produced PLD in mice, rats and dogs at all tested doses, even after a single dose, mainly in the monocytic-phagocytic system; its M2 and M3 metabolites were stronger inducers than the parent 539.

Confirmation matters. For lomitapide, early electron microscopy called the rat lung finding pulmonary PLD, but later examinations found mainly neutral-lipid vacuoles without the lysosomal inclusions characteristic of classical PLD, and the reviewer described the interpretation as uncertain 10121013. For dalbavancin (Xydalba), CHMP rejected the applicant's attribution of pigmented, vacuolated cells to PLD as unsupported because no histological analysis had identified it. CHMP nonetheless required no further studies 659660. For osimertinib, FDA and CHMP both noted rat lung ultrastructure consistent with early PLD in females but also with lipofuscinosis or multivesicular bodies 97811571158.

In vitro data can also enter the assessment. For netarsudil, PLD in Chinese hamster ovary cells (EC50 1.1 µM) was considered attainable in the cornea. Both agencies treated PLD as a plausible, though not established, mechanism for monkey corneal haze and patient corneal verticillata 915918930931. In the reverse case, daprodustat and nine metabolites showed no significant activity in PLD assays 841.

Exposure margins

Margins are central, and reviewers present them in PLD-specific tables where the data allow. The FDA pimavanserin review tabulated no-effect margins for lung PLD of 13-fold in mice, 0.7- to 2.0-fold in rats and 3.8- to 4.1-fold in monkeys 770. For bedaquiline, the FDA safety-margin table listed no NOAEL and no AUC margin for PLD in any species, and one rat study found PLD at about half of clinical exposure 540541.

High margins weigh heavily in favor of the product. For vorapaxar, FDA's clinical reviewer gave most weight to the monkey finding at more than 100 times human exposure and said PLD should not bar approval 956958959. For linagliptin, reviewers judged human clinical risk minimal given that the chronic rat lung finding occurred at about 418 times the maximum recommended human dose (MRHD) 12001202. For brensocatib, rat lung PLD occurred at 152 to 202 times MRHD and the FDA review called its human relevance "not clear" 1022. CHMP accepted that the finding was not expected to be clinically significant 469.

Low margins do not automatically block approval, but they shift the burden. For berotralstat, FDA called AUC margins of 0.1 to 0.8 "generally irrelevant" because the limiting findings were attributable to PLD, which had not been seen in humans in clinical trials 864865. For netupitant, animal-to-human AUC multiples were 0.4 to 1.8, but daily animal dosing contrasted with human dosing no more often than every three weeks 816817821.

Reversibility

Reviewers distinguish complete, partial and slow reversal. Bedaquiline PLD was "slowly reversible" 5425431346. Cariprazine lung PLD did not reverse after one to two drug-free months 11171255. Pimavanserin findings resolved in monkeys after four months but persisted in several rat tissues after six months 769771. Berotralstat PLD in the nine-month monkey study was "not readily reversible", with most findings remaining after 13 weeks 863. In contrast, CHMP accepted brensocatib lung PLD as completely reversible 468.

Associated toxicity and functional consequence

This is where most adverse calls are made.

  • Lung. In 26-week rat studies of ibrexafungerp, marked alveolar foamy-histiocyte accumulation correlated with labored breathing and impaired respiration at about 10 times recommended human exposure. The FDA reviewer noted that awareness could help if related events emerged with longer clinical use 697698699. In rats given pimavanserin, lung inflammation and fibrosis were judged secondary to pulmonary PLD, and severe involvement was associated with morbidity or death 772773774775. For posaconazole, CHMP noted that PLD generally lacked functional effects except in the two-year rat study, where severe alveolar obstruction affected respiration 424425. For camizestrant (Etcamah), the female rat lung finding after six months was adverse because of an inflammatory infiltrate. It occurred at 60 times human exposure and was considered unlikely to be meaningful in humans 453454.
  • Kidney and liver. Rat PLD with pimavanserin was linked to kidney degeneration and raised BUN/creatinine 772. FDA linked liver-enzyme and histologic findings with telithromycin to PLD, while the label concluded its significance for humans was unknown 652653.
  • Nervous system. With posaconazole, dogs alone showed neuronal vacuolation. Neurotoxicity testing at about three times human exposure found no functional deficit 426427. For rezafungin, CHMP assessed Schwann-cell inclusions in rats and monkeys as PLD without degeneration or nerve-conduction change 10291030.
  • Muscle. For bedaquiline, CHMP noted muscle changes with raised CK/ALP. However, the proposed mechanism of myopathy was not PLD itself, and CHMP concluded that significant PLD was unlikely at human exposures 892893894.

When phospholipidosis changed development requirements

Product (INN)AgencyDevelopment consequence tied to PLD
Juxtapid / Lojuxta (lomitapide)FDAPartial clinical hold (June 2007) on trials longer than six months; request for a three-month rat study with recovery, an established pulmonary PLD NOAEL and electron microscopy. Hold kept until February 2010 after deficient responses 10161371. Spirometry and DLCO used in trials 10141018.
Akynzeo (netupitant/palonosetron)FDA, EMAFDA requested chronic rat and dog studies to assess PLD 822823. IRT-QT consult recommended cardiac electron microscopy and suggested phase 3 LVEF/troponin monitoring be considered 824825. In the EU, clinical development included liver-function tests and examination for lamellar bodies 584586.
Nuplazid (pimavanserin)FDAPostmarketing commitment 3069-4: special-stain re-evaluation of rat and monkey lung tissue for collagen and identification of a NOEL for lung inflammation 13641365.
Orladeyo (berotralstat)FDA, EMAFDA agreed urinary BMP was not clinically useful for phase 3 monitoring but considered the proposed safety database inadequate given PLD potential and reliance on end-organ toxicity for detection 866. Pulmonary diffusion measured in two studies 623. EU RMP: required NI-PASS and paediatric study 6256261328.
Orgovyx / Myfembree / Ryeqo (relugolix)FDA, EMAPhase 2 ophthalmologic exams and biomarker studies, then visual acuity in phase 3 720. A development-stage request asked for visual-acuity results to monitor for ocular PLD 1060. FDA said mechanistic biomarker studies were not needed for approval 721. PLD was among clinical safety parameters in the EU dossier 839.
Rhopressa / Rhokiinsa (netarsudil)FDA, EMAFDA requested short- and long-term visual-function evaluations for corneal deposits 919. CHMP supported a post-authorisation safety study of longer-term safety, including the deposits 936935.
Vraylar / Reagila (cariprazine)FDA, EMAFDA requested an explanation of the PLD-toxicity relationship and a review of dog lung histopathology, answered with an expert report 11251126. PLD/fibrosis tracked as an adverse event of special interest in trials 880.
Rezzayo (rezafungin)EMATremor monitoring as a potential adverse event 1032. PIP modification advice to discuss a possible PLD and monkey tremor association in scientific advice 1033.
Brinsupri (brensocatib)EMAUnder PRIME, the signal prompted a call for careful safety characterisation 470471.
SolithromycinEMACHMP requested further discussion of the toxicological meaning and potential human implications of PLD 499.

Three patterns stand out.

  1. Pulmonary PLD with uncertain long-term reversibility draws the strongest action. Lomitapide's hold was imposed because the long-term risk of pulmonary PLD could not be assessed 1016. It was lifted partly because similar animal findings with approved products had not translated into clinical risk 1372.
  2. Monitoring targets the plausible end organ, not PLD itself. There is no validated clinical biomarker. The EU bedaquiline RMP states this directly 895. FDA declined urinary BMP as a phase 3 monitoring tool for berotralstat 866. Monitoring therefore uses functional proxies such as DLCO, visual acuity, ophthalmologic exams and organ-specific laboratory tests 1014720584.
  3. Organ-toxicity monitoring is often broader than PLD. For bedaquiline, FDA's medical officer tied close trial monitoring to animal organ toxicities generally, not to PLD specifically 550. The EU SmPC notes that effects on the monocytic phagocytic system were not monitored clinically 897.

EU risk management plans

Under the EU RMP framework, CHMP has handled PLD in different ways.

  • Important potential risk with routine risk minimisation. Vorapaxar (Zontivity) listed PLD as an important potential risk, with SmPC section 5.3 as the only risk-minimisation measure 107810791082.
  • Important potential risk later removed. Netupitant PLD (Akynzeo) was an important potential risk in the initial RMP and was later removed from the list of safety concerns 5895901327.
  • Important potential risk with additional pharmacovigilance. Berotralstat PLD is addressed by a required non-interventional PASS and paediatric study, because human relevance is unknown, particularly with lifelong treatment 624625626.
  • Enhanced pharmacovigilance. For posaconazole, the plan called for evaluating potential PLD signals, with pulmonary events monitored postmarketing 4294301329.
  • Key nonclinical finding only. Bedaquiline, adagrasib and nirogacestat list PLD in the nonclinical safety specification without making it a separate risk item 895794904.

Labeling practice

United States

FDA places animal PLD in Section 13.2. Typical text describes species, tissues, exposure multiples, reversibility and a statement that human relevance is unclear. Examples:

  • Nuplazid: PLD most affected lungs and kidneys. In rats at 10 times or more MRHD exposure it was associated with rales, labored breathing and renal tubular degeneration, with deaths at 16 times or more. The label states that "the relevance of these findings to human risk is not clear" 12381239. Labeling language was proposed in the nonclinical review 776.
  • Krazati: Findings at 150 mg/kg or more in rats (2 times or more human AUC) and 25 mg/kg in dogs (about equal to human AUC). Reproductive findings are also captured under 13.1 114811531154.
  • Sirturo: PLD in all species "at almost all doses, even after very short exposures", slowly reversible 13461347.
  • Orgovyx/Myfembree: Evidence of reversibility, significance in humans unknown 7181062.
  • Vraylar: Not reversible after one to two drug-free months, at clinically relevant exposures, including juvenile rat lung findings suggestive of PLD 12551256.
  • Ketek: Older-format labeling described PLD under ANIMAL PHARMACOLOGY with dose multiples 649.

FDA did not always add label text. The retrieved Zontivity prescribing information excerpts do not mention PLD 131913201321. For safinamide, FDA's cross-discipline reviewer concluded only that the importance of PLD was unknown 487.

European Union

CHMP places animal PLD in SmPC section 5.3. Examples include artenimol/piperaquine (Eurartesim), where repeat-dose findings at exposures similar to clinical exposure were considered possibly relevant to clinical use 847849. Others include dronedarone (described as slight, reversible, species-specific and not relevant to humans) 563, safinamide 783, gilteritinib 1181, cariprazine 881, camizestrant 457, nirogacestat 905, imlunestrant 982, crizotinib 672 and memantine 966. For telithromycin, section 5.3 was updated after a re-evaluation of PLD-associated changes in five pivotal repeat-dose studies 1263. CHMP also accepts omission where justified: for rezafungin, it agreed that no PLD text was needed in the SmPC 10291030.

Clinical PLD in patients

Two older cationic amphiphilic drugs show how PLD is labeled once documented in humans.

  • Hydroxychloroquine (Plaquenil, revised 12/2023): Section 5.1 links cardiomyopathy to PLD on endomyocardial biopsy and notes PLD may occur in other organs. Sections 5.8 and 5.11 describe PLD on muscle, nerve and renal biopsy. The label advises cardiac monitoring as clinically indicated, periodic muscle strength and reflex assessment, and discontinuation if toxicity is suspected or shown by biopsy 1294129512961297.
  • Amiodarone (Cordarone): Under Pulmonary Toxicity, PLD (foamy cells, foamy macrophages) is present in most cases of drug-induced pulmonary toxicity but also in about 50% of all treated patients. The label therefore treats these cells as markers of therapy, not toxicity, and relies on baseline and periodic chest X-ray and pulmonary function testing 121812191220.

These precedents help explain why reviewers compare new findings to amiodarone. For pimavanserin, toxicologists considered the animal lung findings likely clinically relevant, but not suggestive of the irreversible fibrosis associated with amiodarone 1276.

Same product, different emphasis: FDA versus EMA

ProductFDAEMA
BedaquilineNo PLD NOAEL or AUC margin in any species. PLD not shown to cause functional change. Section 13.2 text 5405451346Significant PLD unlikely at human exposures, yet RMP says relevance unknown and no validated biomarker. SmPC 5.3 894895897
VorapaxarPrincipal toxicology finding. High monkey margin considered most relevant. Should not bar approval 952958959Important potential risk in RMP. SmPC 5.3 states margins acceptable and clinical significance unknown 10781082
SafinamideImportance unknown. Rat lung PLD possibly contributing to respiratory distress 487489Unlikely to be clinically significant. Described in SmPC 5.3 782783
DronedaroneFoamy macrophages in rat lungs and other tissues noted 593594Species-specific and not relevant to humans. A later pulmonary safety review could not establish whether PLD explained postmarketing pulmonary toxicity 559561562
AdagrasibAdverse at high rat doses with deaths, otherwise not. Section 13.2 11501153Most margins below 1. RMP notes trial laboratory monitoring across affected organ systems. SmPC 5.3 791794795
NetupitantChronic studies requested. Uncertain clinical significance 822821Important potential risk later removed. SmPC 5.3 5891327584

The differences reflect emphasis more than conflicting science. CHMP more often formalizes the finding in the RMP and SmPC 5.3. FDA reviewers more often deal with it through pre-submission requests, study-specific risk discussions and Section 13.2 text.

Practical implications for sponsors

The following points are drawn from the review precedents above.

  • Characterize early and specifically. Confirm PLD by electron microscopy or equivalent, separate it from neutral-lipid or lipofuscin accumulation, and include metabolites. Ambiguous characterization prolonged the lomitapide hold 10121371 and drew an "unsupported" finding for dalbavancin 659.
  • Present PLD-specific margins and recovery data. Reviewers built PLD-specific margin tables when they could 770540. Long recovery arms address the persistence questions raised for cariprazine, pimavanserin and berotralstat 1255771863.
  • Separate adaptive from adverse. Pathology peer review that distinguishes foamy macrophages alone from inflammation, fibrosis or functional effect was decisive for cariprazine and adagrasib 11231150.
  • Plan functional clinical monitoring for the target organ. DLCO, visual acuity and organ-specific laboratory tests have been accepted in place of a PLD biomarker 1014720866.
  • Expect labeling. In both regions, a confirmed multi-organ PLD finding near clinical exposure will most likely appear in Section 13.2 or SmPC 5.3, usually with a statement that human significance is unknown 114810628971082.

Across these reviews, phospholipidosis changed the development path when it was tied to functional injury, thin margins, or an uncertain long-term pulmonary risk; otherwise it was handled mainly through nonclinical labeling and, in the EU, the risk-management plan.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.