Rhizome

How FDA Evaluates Recall Periods for Patient-Reported Symptom Outcomes: 24-Hour, 7-Day, and Daily Diary Designs

Chetan Mishra
Chetan Mishra
Oct 16, 2026

The recall period is one of the first design choices for a patient-reported outcome (PRO) symptom measure, and one of the hardest to change later. When the window does not fit how the symptom behaves, how the drug is dosed, or what patients can reliably remember, FDA reviewers can question the instrument's content validity. That puts the endpoint, and any labeling claim based on it, at risk. Clinical outcome assessment (COA), clinical and regulatory teams need to know how the agency has actually judged these choices before they lock a protocol or an instrument.

The analysis below looks at how FDA has treated 24-hour, 7-day and daily diary recall periods across its PRO and COA guidance, its clinical outcome assessment reviews and approved product labeling. It covers the criteria reviewers apply, the cases where longer windows were accepted or questioned, how diary procedures and anchor alignment affected FDA's conclusions, and what this record means for sponsors justifying a recall period in a development program.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.

How FDA evaluates recall periods (24-hour, 7-day, daily diary) for patient-reported symptom outcomes

FDA has no default recall period for patient-reported outcome (PRO) symptom measures. Across guidance, clinical outcome assessment (COA) reviews and approved labeling, the agency asks the same few questions every time. Can patients accurately recall the concept over the stated window? Does the window fit how the symptom fluctuates and how the drug is dosed? Do diary procedures make each entry actually cover the intended interval? And does the recall period of the symptom measure match the recall period of the anchors used to interpret it? For daily-varying symptoms, short recall (past 24 hours, or "today") collected in a daily diary is the most common outcome. Reviewers have still accepted longer windows where evidence supported them, and have criticized 24-hour designs that were badly implemented.

Key takeaways

  • Recall period is a content-validity question. FDA expects sponsors to justify it based on patients' ability to recall validly, the instrument's purpose, the concept, the condition and the treatment 309310.
  • Short recall is generally preferred for fluctuating symptoms. Questions that ask patients to remember long periods, compare against an earlier state, or average experience over time are likely to undermine content validity 17.
  • A 7-day recall is not categorically ruled out. FDA has, however, asked sponsors for qualitative evidence justifying 7-day over 24-hour recall 10648.
  • A daily diary does not guarantee good data. Reviewers look at completion windows, lockouts, retrospective entry, and how many days are needed to compute a weekly score 12151211.
  • Recall alignment between a PRO and its anchor affects labeling. Mismatches have limited the interpretation of meaningful-change thresholds and moved claims toward descriptive language 8486117.

The guidance framework

The 2009 PRO guidance

The 2009 guidance Patient-Reported Outcome Measures: Use in Medical Product Development to Support Labeling Claims defines the recall period as the time patients are asked to consider when answering an item. It can be momentary (real time) or retrospective. FDA says it will look for steps taken to make sure patients understood the recall period 309310. The guidance generally favors current or recent state over extended recall. It warns that recall-based answers may be influenced by how the patient feels at the moment of recall, and that differential recall can add noise and obscure treatment effects 17. When detailed retrospective reporting is needed, FDA suggests asking about the worst or best experience during the period, or using a diary 311. For unsupervised diaries, FDA will check that the protocol makes patients complete entries as the design requires, and not retrospectively just before a clinic visit 12.

PFDD Guidance 3 (fit-for-purpose COAs)

The Patient-Focused Drug Development guidance Selecting, Developing, or Modifying Fit-for-Purpose Clinical Outcome Assessments repeats that no single recall period applies to every PRO. The period should be clearly specified, short enough to limit recall-related error or bias, and still manageable for respondents. It should also suit how frequent and memorable the events are 105106. FDA recommends discussing the planned period with the agency. Patient interviews can show how accurately patients recall different windows, and sponsors may need evidence comparing longer and shorter recall periods 105106.

Indication-specific guidances

Many disease-specific guidances turn these principles into concrete recommendations:

Indication (guidance status)Recall or reporting recommendation
Hemorrhoid symptoms, locally applied corticosteroids (draft)Worst itch, discomfort, pain or burning, assessed daily over the past 24 hours, to minimize recall and measurement error 265266
Erosive esophagitis (draft)Recall of no more than 24 hours, completed at the same time each day 108
Gastroparesis (draft)Daily patient reporting, explicitly to avoid recall error 110271
Chronic pain, non-opioid analgesics (draft)Daily pain scores; averaging seven daily scores reduces the impact of day-to-day variability 97
Eosinophilic esophagitis (final); celiac disease (draft)Daily assessment with past-24-hour recall or an event log, with worst severity for symptom ratings and event logs for discrete episodes 27092
Chemotherapy-induced nausea and vomiting (draft)Daily assessments, for example past-24-hour recall, at the same time each day 269
COVID-19 symptoms (final)Worst severity over the past 24 hours, completed at least every 24 hours at the same time each day; event-driven diaries for frequent episodes such as vomiting or diarrhea; global impression items may use "now," past 24 hours, or past week depending on intent 26413111109
Low sexual interest, desire and/or arousal in women (draft)No more than 24-hour recall for as-needed drugs; daily or weekly recall for continuously administered drugs 267268
Pediatric GERD (draft)Daily diaries or current-state assessments generally preferred to longer recall for children 272
Ulcerative colitis rectal bleeding (draft)Most severe category in a given 24-hour period, captured in diaries for at least 7 days before each visit, with lockout times considered to protect the recall period 273275

Two distinctions in these documents matter for endpoint construction. First, the IBS guidance's "worst abdominal pain in the past 24 hours" is the daily recall question, while the responder definition uses the weekly average of those daily scores. Averaging does not turn a daily worst-pain rating into an average-severity rating 125. Second, the allergic rhinitis guidance separates reflective scores (severity over a predefined interval, such as 12 hours) from instantaneous scores (severity just before the next dose) and links each to a different efficacy question 126127.

How COA reviewers have evaluated 24-hour recall

Reviewers have not treated "past 24 hours" as automatically acceptable. They look for qualitative evidence that patients can use the window, and they check whether the administration schedule produces comparable 24-hour intervals.

Supported by patient interviews:

  • Tremfya (guselkumab), Psoriasis Symptom and Sign Diary. In cognitive interviews, 18 of 19 participants felt they could recall symptoms accurately over 24 hours. Participants who compared versions said daily reporting would be more accurate than a 7-day version, though some preferred less frequent completion. The 24-hour version supported a major secondary endpoint 228149.
  • Omvoh (mirikizumab), Urgency NRS. Interviewees reported no difficulty with the past-24-hour window. A follow-up group with lower education levels also endorsed it, and the reviewer concluded the instrument appeared content valid for its proposed use 229146147.
  • Bimzelx (bimekizumab), HS Symptom Daily Diary. All 20 interviewees said they considered the 24-hour period and could recall it accurately, although two also thought about broader periods such as "bad days" 144.
  • Lucemyra (lofexidine), SOWS-Gossop. Interviews generally supported 24 hours as optimal for acute withdrawal severity, but FDA noted that the modified instructions, including the recall wording, lacked clarity 150.
  • Cosentyx (secukinumab), Psoriasis Symptom Diary. FDA agreed with the selected items and their 24-hour recall 211.

Implementation and design concerns:

  • Palsonify (paltusotine), Acromegaly Symptom Diary. Each item asked about the past 24 hours, but the diary could be completed from 3 p.m. until 9 a.m. the next morning. FDA was concerned that entries made at different times would not represent the adjacent, non-overlapping 24-hour intervals the analysis assumed, which could reduce validity 151152.
  • Ojjaara (momelotinib), MPN-SAF TSS. FDA recommended daily electronic reporting with past-24-hour recall. It preferred this to an undefined comparison with the period before disease onset, which could be hard to recall after longstanding disease 154155156.
  • Eohilia (budesonide), DSQ v5. Items that had referred to the past 24 hours were reworded to "today" after FDA feedback 153.
  • Emgality (galcanezumab), MSQ v2.1. The reviewer found a 4-week recall potentially appropriate for episodic migraine but suggested a shorter window, such as 24 hours, might be more meaningful in chronic migraine 163.

How reviewers have evaluated 7-day and longer recall

Week-long and longer windows get the most scrutiny when the concept fluctuates, when patients must count events, or when patients must compare against a remembered baseline.

  • Skyrizi (risankizumab), CSS. FDA asked for qualitative research in the target population to justify a 7-day recall instead of past 24 hours. It also recommended consistent diary completion times and an e-diary lockout to preserve the intended window 48116.
  • Addyi (flibanserin), FSFI desire domain. Reviewers concluded that neither 7-day nor 28-day recall was appropriate for sexual desire, which can change daily. The Division favored daily electronic capture with an entry window of no more than about 3 days 45180181182. A separate review noted continued uncertainty: most participants preferred 1 to 4 weeks, while about one in five preferred 24 hours 115.
  • Cabometyx (cabozantinib), EORTC QLQ-C30 and QLQ-BN20. FDA said it lacked evidence that asking patients to remember and average one week was appropriate for each concept, particularly fluctuating symptoms such as pain 186.
  • Amitiza (lubiprostone), weekly global IBS relief question. The main concern was the comparison with remembered baseline symptoms from as much as three months earlier, rather than the 7-day window itself. The reviewer said sequential, non-comparative 7-day severity ratings could have avoided this 53.
  • Dexilant (dexlansoprazole). The reviewer treated direct daily eDiary reports as the main efficacy source and less subject to bias. Seven-day recall could introduce bias, particularly in pediatric patients 221222.
  • Varithena (polidocanol), VVSymQ. After FDA raised concerns about the original 7-day recall, the revised daily diary used past-24-hour worst-severity items and "last night" items for nighttime symptoms 223224.
  • Emend (aprepitant), FLIE. FDA questioned whether extending recall to 5 days validly summarized a changing post-chemotherapy experience, because responses might reflect the patient's current state. It preferred a daily 24-hour diary, contingent on that version's validity being confirmed 158159160219.
  • Movantik (naloxegol), BLSRQ. A 2-week recall was considered too long for a questionnaire that asks patients to count bowel movements, occurrences and laxative use. Reviewers pointed to instruments using daily to prior-week recall 185.
  • Tysabri (natalizumab), IBDQ and SF-36. Two-week averaging and comparative items could increase error. The reviewer advised asking about current state, and said the SF-36's 1-week recall may jeopardize validity 187188.
  • Otezla (apremilast), BSAS. A 4-week window may be too long for patients to remember the number of new ulcers or lesions 183.
  • Chantix (varenicline). Monthly recollection of smoking behavior could give a false sense of precision. FDA suggested daily diaries or IVRS 191.

Missing or inconsistent recall instructions are also a deficiency on their own. For Ajovy (fremanezumab), HIT-6 items 1 to 3 stated no period while items 4 to 6 used the last 4 weeks. FDA recommended a clearly specified, standardized recall period 190.

Daily diaries: timing, lockouts and missing data

FDA reviews diary operations as part of measurement validity:

  • Entry windows and lockouts. In Addyi, FDA limited desire entries to a 24-hour window because a mental state is more vulnerable to recall bias than an event. Satisfying-event entries could be made up to 3 days later 207208. A reviewer did not accept "diary fatigue" as a reason to replace daily capture with 28-day recall, noting that about 99% of captured events were entered within 72 hours 209. Guidance also suggests reasonable lockout windows to preserve the intended recall period 1819.
  • Electronic features. FDA recommends reminders and time-stamped completion to support compliance and reduce missing data, plus a backup plan where applicable 141516.
  • Paired assessments. For Livmarli (maralixibat), FDA checked whether caregivers completed morning and evening ItchRO(Obs) entries together. Only three pairs were less than 6 hours apart, and the effect on data quality was judged minimal 218.
  • Forced-response design. In Palsonify, FDA warned that requiring all nine items before saving could discard the seven responses needed for the total score 205240.
  • Minimum data rules for weekly scores. Cosentyx, Tremfya, Nemluvio and Anzupgo all required at least 4 of 7 daily entries to compute a weekly score. Weeks with fewer entries were treated as missing 211212213214215216217. In Vyleesi, substantial missingness in the daily EDQ (over 31% and 36% of patients in the two studies had no more than three baseline-week entries) led reviewers to exclude weekly averages based on fewer than four observations 242210.
  • Daily data used to check longer recall. In Vyleesi, correlations between daily and 4-week desire items gave some support for the longer-recall desire endpoint. They could not show whether 4-week recall was appropriate for distress 161210.

Recall alignment between PROs and anchors

A recurring issue in recent reviews is a mismatch between the recall period of the target PRO and that of the global impression anchor used to derive meaningful-change thresholds:

  • Dupixent (dupilumab), eosinophilic esophagitis. The PGIS asked about the past week, but the DSQ total covered 14 days. FDA said this complicated anchor-based analyses, ran supplementary analyses on matching 7-day periods, and recommended that future PGIS recall match the DSQ period (for example, "past 14 days") 11711851.
  • Eohilia (budesonide). The 14-day DSQ assessment period did not match the 7-day severity anchor, leaving the proposed meaningful-change threshold unclear. FDA recommended a matching 14-day anchor in future studies 86.
  • Lynavoy (linerixibat). A past-24-hour PGI-S did not align with the one-week period of the WIS and WSS scores, which reduced its usefulness as a reference measure 157. For a 7-day PBC-40 variant, the COA reviewer did not review the evidence dossier, so no FDA conclusion on that version is available 54.
  • Sofdra (sofpironium). The review identified a past-week PGI-S paired with an HDSM-Ax-7 assessment recalling "since waking yesterday" 52.

How recall periods appear in labeling

Recall period affects whether a PRO endpoint is interpretable enough to support a claim. In approved labels, the recall question and the aggregation period are described separately:

  • Trulance (plecanatide), IBS-C. A responder is defined by "a decrease in the weekly average of worst abdominal pain in the past 24 hours score (measured daily) of at least 30% compared with baseline weekly average," captured in a daily electronic phone diary, and met in at least 6 of 12 weeks 297.
  • Viberzi (eluxadoline), IBS-D. Eligibility and the primary composite endpoint are based on daily worst abdominal pain in the past 24 hours compared against a baseline weekly average, from electronic daily diaries 295296.
  • Dupixent (dupilumab), prurigo nodularis. Patients rated "the intensity of their worst pruritus (itch) over the past 24 hours" on the WI-NRS. The endpoint was the proportion with a 4-point or greater reduction at Week 24 293294.
  • Amitiza (lubiprostone). The label describes a weekly global relief question covering the past week compared with before study entry 263. Addyi describes FSDS-R Question 13 with a 7-day recall as a secondary endpoint 262.

Recall problems have also limited claims. For Nocdurna (desmopressin), FDA considered the NQoL's 2-week recall problematic for a fluctuating condition. That prompted development of the NI Diary, but neither instrument's results supported labeling claims, partly because the analyses were exploratory 83. For Bimzelx in plaque psoriasis, the Patient Symptom Diary used previous-24-hour recall, but the anchor's recall did not match the endpoint assessment period. That limited threshold interpretation, and FDA supported a descriptive claim for itching, pain and scaling instead 845885. For Emend, FDA asked for evidence supporting the 5-day FLIE recall and cautioned that broad labeling wording about nausea and vomiting impact could mislead without supporting nausea data 158159.

Practical implications for sponsors

  1. Justify the window with qualitative data. Interview evidence that patients can accurately use the window is what reviewers cite when they accept it (Tremfya, Omvoh, Bimzelx). Requests for qualitative justification follow when it is missing (Skyrizi) 22822914448.
  2. Match recall to symptom dynamics and dosing. Daily or 24-hour recall suits fluctuating symptoms and as-needed dosing. Event logs suit discrete, frequent episodes 26792111.
  3. Specify the aggregation separately. Define the daily recall question, the weekly averaging rule, and the minimum number of daily entries in advance 125211213.
  4. Engineer the diary to protect the recall period. Use consistent completion times, lockouts, reminders and time stamps. Avoid completion windows that create overlapping intervals 4815114.
  5. Align anchor recall periods with the target PRO. Mismatches have repeatedly reduced the interpretability of meaningful-change thresholds and the specificity of labeling claims 1178684.
Rhizome did this research. Let it help you with your most critical decisions by creating a free account.