Rhizome

FDA Evaluation of Dystrophin Expression and Functional Endpoints in Duchenne Muscular Dystrophy

Chetan Mishra
Chetan Mishra
Oct 16, 2026

Sponsors developing therapies for Duchenne muscular dystrophy face a central regulatory choice: pursue accelerated approval on a dystrophin-based surrogate endpoint, or build the case for traditional approval on a clinical outcome assessment. FDA's precedent here shapes trial design, assay validation strategy, control-group selection, and confirmatory-trial planning. The agency's reviews and advisory committee discussions have repeatedly tested how much evidence each route requires.

The analysis below reviews FDA guidance on dystrophin as a biomarker, the evidentiary basis for each exon-skipping and gene therapy approval, and the corticosteroid and HDAC-inhibitor approvals that relied on functional endpoints. It also covers recurring review issues, including assay reliability, the size of dystrophin increases, and how effort-dependent motor tests have been interpreted against external or historical controls.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.

How FDA evaluates dystrophin expression and functional endpoints in Duchenne muscular dystrophy

FDA has used two evidentiary routes for Duchenne muscular dystrophy (DMD) products. The first is accelerated approval based on an increase in dystrophin (or an engineered micro-dystrophin) as a surrogate endpoint. The four exon-skipping antisense oligonucleotides and the original Elevidys gene therapy approval all took this route. The second is traditional approval based on a statistically significant effect on a clinical outcome assessment such as muscle strength, time to stand, or 4-stair climb. Deflazacort, vamorolone and givinostat took this route. Across the record, the contested questions have stayed the same: how much dystrophin is enough, whether the assay and controls can be trusted, and whether effort-dependent functional tests can be read against external or historical controls.

Key takeaways

  • FDA guidance calls dystrophin a biomarker of particular interest and a potential surrogate endpoint for accelerated approval. It is not an automatically validated one, and its use requires sufficient scientific evidence and acceptable analytical methods 56.
  • Exon-skipping approvals rested on small increases in truncated dystrophin: about 0.2 to 0.3 percentage points of normal for eteplirsen, 0.92 points for golodirsen, a 0.594-point placebo-adjusted difference for casimersen, and about 5.3 to 5.4 points for viltolarsen 111112113257142323324.
  • FDA has repeatedly said that the amount of dystrophin needed for clinical benefit is unknown 259144328. One review states that the regulations set no numerical threshold for the "reasonably likely" judgment 114115116.
  • For micro-dystrophin, CBER reviewers said that measuring an engineered transgene product shows expression, not necessarily benefit. The randomized data did not show a clear link between expression and North Star Ambulatory Assessment (NSAA) outcomes 287288289290291.
  • In several of these files the reviewers and the final decision-maker disagreed. The Center Director overruled the review team on eteplirsen 410411 and on the original Elevidys approval 463464, and the CBER Center Director again reached a different conclusion from reviewers on the 2024 Elevidys supplement 168169.
  • Traditional approvals each rested on a single prespecified functional primary endpoint, and for givinostat FDA also relied on confirmatory evidence after a missing-data sensitivity analysis lost significance. FDA was explicit when secondary functional endpoints did not survive multiplicity adjustment 225226194351354.

FDA's guidance framework

FDA's DMD guidance treats dystrophin deficiency as the apparent driver of the disease's symptoms and functional consequences. That is the basis for considering dystrophin a potential surrogate 56. Baseline dystrophin may be prognostic. An increase may indicate drug activity and help guide dose or route selection 56. Interpretation may depend on the size of the change, the tissue sampled, disease stage or age, and patient factors. Sponsors are expected to demonstrate analytical validity where possible, assess assay performance, and document quality control. Trials with clinically meaningful endpoints should also collect relevant biomarkers so that biomarker-outcome correlations can be established 7.

The guidance does not prescribe a fixed set of clinical outcome measures. Instead it asks sponsors to:

  • agree on endpoints with FDA early;
  • assess multiple endpoints when feasible;
  • choose measures that capture improvement as well as decline without floor or ceiling effects;
  • cover skeletal, respiratory and cardiac function even if only one of them is primary 419420.

The guidance gives these stage-specific pointers:

PopulationMeasures FDA identifies as potentially usefulCaveats noted
Ambulatory, age 3 and olderNSAA (or an age-appropriate modification); timed tasks such as 4-stair climb and 10-meter walk/run 421422None specific
Ambulatory, from about age 5 to 66-minute walk test (6MWT) or a shorter version 421422Age-related improvement versus decline, loss-of-ambulation floor effects, and the resulting analytical problems 421422
Older nonambulatoryUpper-extremity function measures; composite endpoints spanning ambulation and upper-body function 423424420None specific
RespiratoryNocturnal desaturation, aspiration pneumonia, progression to assisted ventilation; vital capacity and inspiratory/expiratory pressures 425Clinical meaningfulness should be supported by the size of the effect or by an effect on a functional measure 425

Exon-skipping antisense oligonucleotides: dystrophin as the accelerated approval surrogate

Eteplirsen (Exondys 51): the precedent-setting case

Assays and early data. FDA evaluated dystrophin in skeletal-muscle biopsies using two methods 104105106:

  • Immunofluorescence/immunohistochemistry (IHC) to count dystrophin-positive fibers and show where the protein was located.
  • Western blot to quantify protein against a normal-muscle reference.

RT-PCR confirmed exon 51 skipping. FDA said that result alone did not establish efficacy 104105106.

In Study 201/202, adequately controlled IHC analyses showed no evidence of increased dystrophin through week 48 107108109110. At week 180:

  • Western blot showed a mean of 0.93% ± 0.84% of normal. The sponsor reported 0.08% in untreated controls, but FDA cautioned that the controls and assay limits complicated the comparison 107108109110.
  • A revised IHC method showed 17.4% positive fibers versus 1.1% in baseline/external-control samples. FDA found these results hard to interpret because the old and new methods differed sharply and IHC did not agree with Western blot 107108109110.

The pivotal biomarker data. FDA asked for additional Western blots from Study 301 (PROMOVI), which had paired biopsies taken at baseline and at week 48 111112113. Usable results were available for 12 of 13 patients. The mean increase was about 0.2 to 0.3 percentage points of normal and was statistically significant. In one imputation approach the increase was 0.218 points, from 0.260% to 0.478% 111112113. Reviewers accepted that dystrophin sits on DMD's causal pathway. Whether this small amount was reasonably likely to predict benefit was treated as a judgment about effect size, with no regulatory numerical threshold 114115116.

Functional endpoints. FDA found no demonstrated functional benefit:

  • The 6MWT showed no significant effect versus placebo through week 24, and no advantage in the prespecified week 48 extension analysis 8081.
  • The sponsor reported a 141-meter difference at 36 months versus historical controls. FDA said the nominal p-value was not meaningful because the comparison was open-label and not adequate and well-controlled 82.
  • FDA cited differences in baseline severity and steroid use; expectation, motivation and coaching effects on walking; unreliable "zero" 6MWT distances in some controls; and unequal testing opportunities between treated and natural-history patients 838485.
  • The review team concluded that the treated patients' course was not clearly distinguishable from natural history 86.

Advisory committee. At the April 25, 2016 Peripheral and Central Nervous System Drugs Advisory Committee meeting on NDA 206488 528, members answered two questions 486487488489:

Voting questionYesNoAbstain
Did the post hoc comparison of 12 treated patients with 13 external controls provide substantial evidence of effectiveness?373
Did adequate and well-controlled studies show enough dystrophin production to be reasonably likely to predict clinical benefit?670

Members questioned biopsy controls, differences in sampled muscles, the lack of a dose-response, and the mismatch between dystrophin levels and clinical results 490. The review noted a disconnect between supportive patient testimony and formal functional testing, which showed worsening 494.

Decision and confirmatory obligation. The review division, supported by the Office of New Drugs Director, favored a complete response. The CDER Director concluded that the surrogate evidence supported accelerated approval and overruled the review team 410411. The review team appealed through the scientific-dispute process. The Commissioner's office found no procedural basis to overturn the decision 412413. The postmarketing requirement was a two-year randomized, double-blind trial comparing 30 mg/kg weekly with a substantially higher-exposure regimen (for example, 30 mg/kg daily), with NSAA as the primary endpoint 414.

Golodirsen (Vyondys 53)

In Study 4053-101 (25 patients), Western blot dystrophin rose from 0.10% to 1.02% of normal after 48 to 59 weeks, an increase of 0.92 percentage points (p<0.001). FDA considered the method adequate 257258. The accelerated approval rationale relied explicitly on the eteplirsen precedent: the increase was similar in magnitude to the one CDER had judged reasonably likely to predict benefit. FDA acknowledged that the dystrophin level needed for meaningful benefit was unknown 259. ESSENCE (Study 4045-301) was designated to confirm benefit 260261.

The golodirsen file shows the surrogate's effect size being weighed against risk. FDA issued a Complete Response Letter on August 19, 2019. The letter cited vascular-access infections and potential renal toxicity, and stated that the small, unverified benefit (about a 0.9% increase in dystrophin) did not outweigh those risks 437439. FDA granted Sarepta's appeal on November 22, 2019. The deciding official concluded that clinically meaningful benefit was reasonably likely and that renal function could be monitored, including with a baseline direct GFR measurement. Accelerated approval followed on December 12, 2019 440441442.

Viltolarsen (Viltepso)

In Study NS-065/NCNP-01-201 (16 boys, 8 per dose), FDA used Western blot normalized to myosin heavy chain as the primary assay. FDA considered this normalization more reliable than α-actinin because it was less variable. Validated mass spectrometry served as a supportive assay 320321322.

After about 24 weeks, dystrophin rose from 0.3% to 5.7% of normal at 40 mg/kg/week and from 0.6% to 5.9% at 80 mg/kg/week. There was no significant difference between doses 323324325326327. Mass spectrometry showed smaller mean changes of 1.5 and 3.7 points 323324325326327. That gap between orthogonal assays is a useful reminder that "percent of normal" depends on the method.

Accelerated approval relied partly on the prior eteplirsen and golodirsen conclusions. The designated confirmatory study used Time to Stand as its primary endpoint 328329.

Casimersen (Amondys 45)

Casimersen is the only exon-skipping approval in this set whose dystrophin evidence came from a randomized, placebo-controlled comparison. In an interim analysis of Study 4045-301, mean Western blot dystrophin increased by 0.811% of normal with casimersen versus 0.217% with placebo, a difference of 0.594 points (p=0.004) 140141142143. FDA treated the increase as reasonably likely to predict benefit while acknowledging uncertainty about the amount required. Clinical benefit was to be confirmed through ESSENCE outcomes, including the week 96 6MWT 144145.

Comparison of exon-skipping dystrophin evidence

ProductPivotal dystrophin studyControlDystrophin change (Western blot, % of normal)Confirmatory approach
EteplirsenStudy 301 (PROMOVI), week 48Own baselineAbout +0.2 to 0.3 points 111112113Dose-comparison RCT, NSAA primary 414
GolodirsenStudy 4053-101, weeks 48 to 59Own baseline0.10% to 1.02% (+0.92) 257258ESSENCE 260261
ViltolarsenStudy 201, about week 24Own baseline0.3% to 5.7% (40 mg/kg); 0.6% to 5.9% (80 mg/kg) 323324Time to Stand primary 328329
CasimersenStudy 4045-301 interim, week 48Placebo+0.811 vs +0.217 (difference 0.594) 142143ESSENCE, including week 96 6MWT 144145

Gene therapy: micro-dystrophin and Elevidys

Framing at the advisory committee

At the May 12, 2023 advisory committee meeting, FDA presented week 12 micro-dystrophin expression as Sarepta's proposed surrogate. The question for the committee was whether it was reasonably likely to predict benefit. FDA said that judgment needed three things: biological plausibility, empirical evidence, and clinical data linking expression to an outcome such as NSAA 3738. FDA stressed that the engineered protein differs from naturally occurring shortened dystrophins 3738.

On function, FDA made three points:

  • Study 102 Part 1, the only randomized, double-blind, placebo-controlled comparison, did not show a significant NSAA effect 39.
  • Exploratory analyses suggested a possible benefit in ages 4 to 5 but none in ages 6 to 7 39.
  • Open-label and external-control NSAA comparisons were unreliable, because NSAA is effort- and administration-dependent, disease progression varies between patients, and the matching methods and covariates raised concerns 4041.

The committee voted 8 to 6 that overall benefit-risk supported accelerated approval in ambulatory patients using week 12 micro-dystrophin as the surrogate 42.

The review record and the June 2023 decision

Expression data. In Study 102 Part 1, Western blot showed significantly greater expression with Elevidys than with placebo (p<0.0001) 287288289.

Link to function. Reviewers gave greatest weight to the randomized data because NSAA is effort-dependent 290291. The findings were:

  • After adjustment for age and baseline, there was no clear relationship between expression and NSAA change 290291.
  • In pooled analyses, expression explained about 11% of the variation in NSAA change 290291.
  • The week 48 NSAA treatment difference was 0.82 points (95% CI −1.03 to 2.67) 292.

Recommendations and decision. The clinical and clinical-pharmacology reviewers recommended against approval, even for a restricted 4- to 5-year-old group 293294. An integrated assessment found the 4- to 5-year-old results sufficient for accelerated approval given the totality of evidence and unmet need 295267. CBER Center Director Peter Marks overrode the review committee's recommendation 463464465. On June 22, 2023, FDA granted accelerated approval for ambulatory children aged 4 through 5 years with a confirmed DMD mutation 462448. The required confirmatory study was Part 1 of Study SRP-9001-301 (EMBARK) 466467.

EMBARK and the 2024 supplement

EMBARK missed its primary endpoint. The week 52 NSAA difference was 0.65 points (p=0.244) 164165166167. Time to rise from the floor and the 10-meter walk numerically favored Elevidys. Because the primary endpoint failed, the statistical reviewer made no inferential claims on those secondary endpoints 164165166167. Reviewers also cited the lack of prespecified multiplicity control and inconsistent 10-meter walk results across studies, and they recommended a Complete Response 164165166167.

The CBER Center Director acknowledged the failed primary endpoint. He judged the secondary and exploratory functional findings, together with other studies, to verify clinical benefit in ambulatory patients 168169. The June 2024 action expanded the indication to patients aged 4 years and older with a confirmed DMD mutation, with a different approval pathway for each population 170171172:

  • Ambulatory patients: traditional approval.
  • Non-ambulatory patients: accelerated approval, based on micro-dystrophin expression, with a confirmatory trial underway.

The label also contraindicates use in patients with deletions in exon 8 and/or exon 9 170171172.

This analysis covers the review record through the June 2024 Elevidys action. Later events, including confirmatory-trial readouts for the exon-skipping products and FDA's 2025 safety actions on Elevidys after reports of fatal acute liver failure, are not analyzed here. Check current labeling and FDA communications before relying on the regulatory status of any product described above.

Traditional approvals on functional endpoints

ProductPivotal trial and primary endpointResultHow FDA handled other endpoints
Deflazacort (Emflaza)NM-001; average muscle-strength score (0 to 10 scale), week 12+0.25 (0.9 mg/kg/day, p=0.0173) and +0.36 (1.2 mg/kg/day, p=0.0003) vs placebo 225226Supportive NM-002 two-year strength result not significant (p=0.2107). Earlier timepoints and time to loss of ambulation were not controlled for multiplicity 227228229230231232
Vamorolone (Agamree)VBP15-004; time-to-stand (TTSTAND) velocity, 6 mg/kg/day, week 24+0.0603 rises/s vs placebo (p=0.0018) 194Key secondaries: TTSTAND at 2 mg/kg/day (p=0.0171) and 6MWT at 6 mg/kg/day (+41.6 m, p=0.0033) significant. 10-meter run/walk significant at 6 mg/kg/day only 195196197198
Givinostat (Duvyzat)Study 48; 4-stair climb time, month 181.78 s less worsening vs placebo (p=0.0374), judged clinically meaningful 351352353NSAA, time to rise and 6MWT favored givinostat but were not significant after multiplicity adjustment 354

The givinostat review shows how FDA handles a single positive study. A missing-data sensitivity analysis lost statistical significance 355356354. FDA still found effectiveness on the 4-stair climb result plus confirmatory evidence: less increase in vastus lateralis fat fraction on MRI and longer-term comparisons with natural history 355356354.

Cross-cutting themes for development programs

  1. Dystrophin magnitude remains a judgment call. Each exon-skipping approval acknowledged that the dystrophin level needed for benefit is unknown 259144328. Later approvals relied on the eteplirsen precedent rather than on a validated threshold 259328.
  2. Assay rigor and controls drive credibility. FDA discounted non-concordant IHC and Western blot data and data from changing methods 107108109110. It preferred Western blot with less variable normalization 320321322. It valued paired-biopsy or placebo-controlled designs 111112113142143.
  3. Engineered proteins raise a separate surrogate question. For micro-dystrophin, FDA asked for clinical evidence that expression tracks function, not just evidence that expression occurred 3738287288289.
  4. External and historical controls for effort-dependent endpoints face heavy scrutiny. FDA's critiques of the 6MWT and NSAA in the eteplirsen and Elevidys files centered on motivation and coaching effects, baseline imbalances, matching methods and testing asymmetries 8384854041.
  5. Multiplicity discipline is applied consistently in reviews. Secondary functional endpoints that fail adjustment are labeled as such, even when they numerically favor the product 354164165166167.
  6. Final decisions have diverged from review-team recommendations. This happened on eteplirsen 410411412413, the original Elevidys approval 463464 and the Elevidys expansion 168169. Sponsors should expect the record to document dissent in detail.

Questions to explore further

Topics worth following up include:

  • the ESSENCE and viltolarsen confirmatory-trial results and their regulatory consequences;
  • the status of the eteplirsen dose-comparison confirmatory trial;
  • FDA's post-2024 safety and labeling actions on Elevidys;
  • the confirmatory trial for non-ambulatory Elevidys patients;
  • how FDA treated MRI fat fraction and other imaging biomarkers as confirmatory evidence across DMD programs.
Rhizome did this research. Let it help you with your most critical decisions by creating a free account.