Rhizome

FDA Approvals Based on a Single Adequate and Well-Controlled Trial Plus Confirmatory Evidence

Chetan Mishra
Chetan Mishra
Nov 1, 2026

FDA's substantial evidence standard traditionally meant two adequate and well-controlled trials. Since FDAMA 1997, a single such trial plus confirmatory evidence can also meet it. For sponsors in small populations, or where a second trial is unethical or impractical, how FDA has applied this route affects program design, the scope of the development plan, and the strength of the submission package.

The analysis below reviews FDA approvals that relied on one adequate and well-controlled trial plus confirmatory evidence, drawing on reviewer assessments in Drugs@FDA and on FDA guidance. It sets out the legal and policy basis for the standard, lists the therapeutic areas where it has been applied, groups the types of confirmatory evidence reviewers accepted, and covers the cases where proposed confirmatory evidence was rejected or discounted.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.

FDA approvals based on one adequate and well-controlled trial plus confirmatory evidence

FDA has repeatedly found substantial evidence of effectiveness on the basis of a single adequate and well-controlled clinical investigation plus confirmatory evidence. This is not limited to rare disease. Reviews in Drugs@FDA apply the standard to enzyme replacement therapies and antisense oligonucleotides, and also to treatments for overactive bladder, major depressive disorder, systemic lupus erythematosus, NASH and ROS1-positive non-small cell lung cancer. The confirmatory evidence reviewers accepted falls into a small number of recurring categories:

  • additional clinical trials that were not independently persuasive;
  • mechanistic and pharmacodynamic data;
  • evidence from a related indication or from other drugs in the same class;
  • animal model data;
  • natural history data.

Reviewers also rejected or discounted proposed confirmatory evidence in several files. Those decisions show where the bar sits.

Legal and policy basis

Section 115(a) of the Food and Drug Administration Modernization Act of 1997 (FDAMA) amended section 505(d) of the Federal Food, Drug, and Cosmetic Act. The amendment clarified that FDA may consider "data from one adequate and well-controlled clinical investigation and confirmatory evidence" to constitute substantial evidence 204. FDA guidance presents this as a case-by-case route, not a default. FDA must determine that the combined evidence is sufficient to establish effectiveness 205206.

Three FDA guidances address the topic:

  • Providing Clinical Evidence of Effectiveness for Human Drug and Biological Products (May 1998) 195
  • Demonstrating Substantial Evidence of Effectiveness With One Adequate and Well-Controlled Clinical Investigation and Confirmatory Evidence (draft, September 2023) 201202
  • Demonstrating Substantial Evidence of Effectiveness for Human Drug and Biological Products (draft, June 2026) 203

When FDA considers the approach appropriate

FDA weighs several factors 181:

  • the design, conduct, analysis and persuasiveness of the single trial;
  • the source and strength of the confirmatory evidence;
  • the seriousness of the disease, unmet need and prevalence;
  • whether a second adequate and well-controlled trial would be ethical and practicable.

The stronger the single trial, the less confirmatory evidence may be needed, and conflicting evidence must also be considered 186. FDA expects sponsors to discuss the plan early. Under the June 2026 draft, that discussion should happen before the single trial starts and should explain the proposed trial and the type and quantity of confirmation 213177214. Establishing effectiveness this way does not settle safety. A further or longer trial may still be needed for an adequate safety and benefit-risk assessment 188.

Categories of confirmatory evidence in FDA guidance

CategoryWhat FDA describes
Clinical evidence from a related indicationTrial results for the same drug in a different but closely related indication. This includes results behind an earlier approval or trials supporting concurrent approval of two related indications 177.
Mechanistic or pharmacodynamic evidenceStrong evidence that a well-understood mechanism directly targets major drivers of a well-understood disease. Pharmacodynamic or relevant in vitro testing can supply it 175176.
Relevant animal modelAnimal model findings may serve as confirmatory evidence. This is distinct from approval under the Animal Rule 191.
Other members of the same pharmacological classAdequate and well-controlled trials of approved drugs in the class. Considerations include shared mechanism and consistency of effects 191.
Natural history evidenceData distinct from the trial's control data that help establish expected outcomes without treatment 207.
Real-world data/evidenceMay be suitable depending on reliability, relevance, study design and prespecified analyses 208209.
Expanded-access outcomesCan be considered if the information is plentiful, high-quality and persuasive. FDA cautions that such information typically has limitations 210.

The June 2026 draft describes related adequate and well-controlled trial data as the generally expected source of strong confirmatory evidence. That includes trials in related diseases or of related products 211. The draft also describes a separate approach: a "Highly Persuasive Adequate and Well-Controlled Trial Plus Early-Phase Confirmatory Evidence" 212.

Approval examples by type of confirmatory evidence

In the table below, "period" is the decision-date window of the FDA review document in which the finding appears. Several examples are supplemental approvals for new indications.

ProductIndicationSingle adequate and well-controlled investigationConfirmatory evidence acceptedPeriod
H.P. Acthar GelInfantile spasms 62Study 01 62Supportive Studies 04 and 05, which were not independently interpretable as positive 62632010 to 2017
Spinraza (nusinersen)Infantile-onset SMA 65Study CS3B 64Open-label Study CS3A, compared with historically expected survival and milestones 64654862010 to 2017
Gemtesa (vibegron)Overactive bladder, 75 mg 25Study 3003 25Studies 301 and 008 at other doses 262018 to 2020
Onpattro (patisiran)hATTR polyneuropathy 28Study 004 28TTR-lowering pharmacodynamics consistent with mechanism; two open-label studies 29302018 to 2020
Epidiolex (cannabidiol)Seizures in tuberous sclerosis complex 31One placebo-controlled trial 3132Established efficacy in Dravet syndrome and Lennox-Gastaut syndrome 312018 to 2020
Arikayce (amikacin liposome)Refractory MAC lung disease 34INS-212 3435Supportive phase 2 trial 352018 to 2020
Prograf (tacrolimus)Lung transplantation 89Non-interventional Study F506-CL-3001 with historical controls 89RCTs in liver, kidney and heart transplant; published reports on calcineurin inhibitor contribution 9089912021 to 2022
Besremi (ropeginterferon alfa-2b)Polycythemia vera 86PEGINVERA 87Pharmacodynamic biomarkers; natural history historical control 884812021 to 2022
Nulibry (fosdenopterin)MoCD Type A 344Pooled treated patients compared with a natural history control 345Urinary SSC reduction with exposure-response; mouse model survival and SSC data 3463473482021 to 2022
Saphnelo (anifrolumab)SLE 99Study 04 100Phase 2 Study 1013 and phase 3 Study 05 considered together 1002021 to 2022
Auvelity (bupropion/dextromethorphan)MDD 102MDD-301 102Study MDD-201 superiority to bupropion 1022021 to 2022
Tzield (teplizumab)Delay of Stage 3 T1D in Stage 2 patients 104105TN-10 104Post hoc meta-analyses of C-peptide in new-onset Stage 3 T1D, with noted limitations 1031062021 to 2022
Bylvay (odevixibat)Pruritus in PFIC 108A4250-005 109Serum bile acid reductions; nonclinical mechanistic studies 1101112021 to 2022
Recorlev (levoketoconazole)Cushing's syndrome 113Randomized-withdrawal COR-2017-01 114Single-arm COR-2012-01 1152021 to 2022
Xenpozyme (olipudase alfa)Non-CNS manifestations of ASMD 462ASCEND 457458Disease etiology; enzyme replacement mechanism; plasma ceramide and lyso-SPM reductions 4594602021 to 2022
Daybue (trofinetide)Rett syndrome 146Study 003 147148Dose-ranging Study 002; exposure-response analyses 1491502023
Lamzede (velmanase alfa)Non-CNS alpha-mannosidosis 293rhLAMAN-05 287288Pathophysiology; mechanism; tissue reach; serum oligosaccharide reduction; exposure-response 2872892023
Iwilfin (eflornithine)High-risk neuroblastoma maintenance 442Study 3(b) compared with an external control from ANBL0032 158ODC/MYCN pathway biology; in vitro mechanism; two mouse tumor-prevention models 4393793802023
Filsuvez (birch triterpenes)Epidermolysis bullosa wounds 160161BEB-13 159Randomized, blinded-assessment burn and skin-graft wound studies 1592023
Wainua (eplontersen)hATTR polyneuropathy 163Externally controlled CS3 164TTR reduction; established effectiveness of inotersen 1651661672023
Elfabrio (pegunigalsidase alfa)Fabry disease 168169PB-102-F01/F02 169Randomized active-controlled PB-102-F20; disease etiology and mechanism 1681692023
Joenja (leniolisib)APDS 171Trial 2201 Part 2 172Disease etiology and mechanism; pharmacodynamic biomarker data 1722023
Veopoz (pozelimab)CHAPLE disease 330Single-arm Study 1878 with pretreatment control 330174Disease mechanism; in vitro and ex vivo complement inhibition (CH50, sC5b-9) 3313322023
Rezdiffra (resmetirom)Noncirrhotic NASH, F2 to F3 361MGL-3196-11 359Phase 2 MGL-3196-05 3602024 to 2026
Livdelzi (seladelpar)PBC 424RESPONSE 417418Week 12 ENHANCE results 4194204212024 to 2026
Miplyffa (arimoclomol)Neurological manifestations of NPC 245NPC-002 246Open-label extension; exposure-response; cell and NPC1-null mouse data 2472024 to 2026
Wayrilz (rilzabrutinib)Chronic ITP 249LUNA 3 250Platelet responses in open-label LUNA 2 2512024 to 2026
Jideytro (zidesamtinib)ROS1+ NSCLC after prior ROS1 TKI 490ARROS-1 252Effectiveness of other ROS1 inhibitors (crizotinib, entrectinib, repotrectinib, taletrectinib) 4892024 to 2026
Ekterly (sebetralstat)Acute HAE attacks 398KONFIDENT (Trial 301) 395HAE pathophysiology; plasma kallikrein inhibition in vitro and in vivo 3963972024 to 2026
Lynavoy (linerixibat)Cholestatic pruritus in PBC 307308GLISTEN Part A 307GLISTEN Part B; phase 2b GLIMMER 3092024 to 2026
Avlayah (tividenofusp alfa)Neurologic manifestations of MPS II 242Single-arm, baseline-controlled DNLI-E-0002 243Nonclinical data; exposure-CSF HS correlation; downstream biomarkers; urinary HS and liver volume 2432024 to 2026

How reviewers applied each category

Additional clinical trials that were not independently persuasive

The most common form is a second clinical study. Reviewers accepted it even when it could not stand on its own as an adequate and well-controlled trial. Examples:

  • Acthar Gel: reviewers accepted Studies 04 and 05 although neither was independently interpretable as positive 6263.
  • Saphnelo: reviewers accepted phase 2 Study 1013 and phase 3 Study 05 considered together. Neither was a separate successful adequate and well-controlled trial 100.
  • Livdelzi: ENHANCE ended early, which made it insufficient as the pivotal investigation. Its Week 12 data were still accepted as confirmatory 419420421.
  • Different doses: in Gemtesa the supporting studies tested other doses 26. In Daybue the confirmatory evidence came from a dose-ranging study 149.
  • Phase 2 trials: reviewers accepted phase 2 trials for Arikayce 35 and Rezdiffra 360.
  • Single-arm or open-label studies: reviewers accepted these for Recorlev 115, Wayrilz 251 and Onpattro 30.
  • Active-comparator data: in Auvelity, Study MDD-201 showed superiority to bupropion and served as confirmatory evidence 102.

Mechanistic and pharmacodynamic evidence

Rare monogenic diseases account for most of these examples. Reviewers usually combined three elements:

  1. a well-established disease etiology;
  2. a mechanism that directly addresses it;
  3. a pharmacodynamic biomarker response.

Xenpozyme 459460, Lamzede 287289, Joenja 172 and Veopoz 331332 follow this pattern. Exposure-response relationships added weight in Nulibry 346, Lamzede 289 and Avlayah 243. Ekterly shows the approach applied outside enzyme replacement. Reviewers accepted HAE pathophysiology plus in vitro and in vivo plasma kallikrein inhibition data as adequate confirmatory evidence 396397.

Related indication, related product or same class

  • Related indication: Epidiolex's tuberous sclerosis complex approval relied on its established efficacy in Dravet syndrome and Lennox-Gastaut syndrome 31.
  • Same drug in related transplant settings: the Prograf lung transplant review cited RCTs in liver, kidney and heart transplantation under its "Confirmatory evidence" heading 90.
  • Same approach in an approved product: Wainua drew on existing evidence that the same antisense approach worked in approved inotersen 167.
  • Same pharmacological class: Jideytro relied on the effectiveness of other approved ROS1 inhibitors in ROS1-positive NSCLC 489.
  • Different disease stage: in Tzield, meta-analyses in Stage 3 disease supported the Stage 2 indication, although the review noted limitations in their strength 103106.

Animal model data

Reviewers accepted animal efficacy data in several reviews:

  • Nulibry: MoCD Type A mouse data showing reduced SSC and improved survival 347348.
  • Iwilfin: two neuroblastoma mouse models in which eflornithine prevented or delayed tumor formation 379380.
  • Nexviazyme: GAA-knockout mouse studies of Pompe disease, cited under "Confirmatory Evidence" 381382.
  • Miplyffa: NPC1-null mouse and cell data 247.

Natural history and external data

Reviewers used natural history data in two ways. Sometimes it formed the control arm of the single investigation, as in Nulibry 345 and Prograf 89. In other files it was the confirmatory evidence itself:

  • Besremi: natural history data used as a historical control group 481.
  • Lytenava (bevacizumab-vikg): disease natural history substantiated the NORSE 2 treatment effect. The reviewer cautioned that it is not an appropriate external control for new therapies 482.
  • Duvyzat (givinostat): reviewers agreed that natural history control analyses could contribute confirmatory evidence for Study 48 483.
  • Aurlumyn (iloprost): two observational studies against standard-of-care and natural history comparators 485.

Skyclarys (omaveloxolone) submitted propensity-matched comparisons with the FA-COMS natural history study as confirmatory evidence. The passage reviewed does not explicitly state final acceptance of those comparisons 484. Likewise, a registry comparison submitted for Yartemlea is described as confirmatory, but no final acceptance conclusion was found 463470474.

Evidence reviewers rejected or discounted

These negative findings are as useful for development planning as the accepted evidence.

  • Xenpozyme: reviewers concluded that the nonclinical findings did not rise to confirmatory evidence. They discounted an underpowered mouse toxicology study 460461.
  • Iwilfin: reviewers did not accept supportive clinical studies in related populations. The reasons were small numbers, difficulty isolating eflornithine's effect and no attributable objective responses 440441.
  • Veopoz: the CD55-knockout mouse was unsuitable as a disease model because it does not show the CHAPLE phenotype 333.
  • Lamzede: serum oligosaccharides counted as pharmacodynamic confirmation but were not treated as a validated surrogate endpoint 291292.
  • Livdelzi: FDA did not accept future, post-approval AFFIRM results as the confirmatory evidence needed for approval. AFFIRM was instead intended to verify clinical benefit after accelerated approval 422423.
  • Lynavoy: reviewers rejected a higher-dose crossover study and evidence from other IBAT inhibitors. They gave an open-label study limited utility and found that the mechanistic and pharmacodynamic evidence did not constitute confirmatory evidence 310311.

Practical takeaways for development programs

  • The single investigation need not be a randomized placebo-controlled trial. FDA accepted externally controlled, historically controlled and single-arm designs as the one adequate and well-controlled investigation:

    In these files, the confirmatory evidence usually had to be mechanistically strong.

  • Mechanistic confirmation works best with a well-defined etiology. It was most persuasive where the disease etiology is well established and a pharmacodynamic biomarker responds in an exposure-dependent way 287289346.

  • Class and related-product evidence depends on the class. Reviewers accepted it for ROS1 inhibitors 489 and for inotersen 167, but rejected it for other IBAT inhibitors in Lynavoy 310. The difference turns on shared mechanism and consistency of effect 191.

  • Confirmatory evidence must exist at the time of approval. Planned post-approval studies did not qualify 422423.

  • Plan early with FDA. Guidance expects sponsors to agree on the type and quantity of confirmatory evidence early, ideally before the single trial begins 213214.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.