Rhizome

Seamless Phase 1/2 and Phase 2/3 Trial Designs: FDA Precedents and Reviewer Requirements

Chetan Mishra
Chetan Mishra
Published Nov 17, 2026 · Updated Nov 23, 2026

Seamless trial designs let a sponsor move from dose finding or dose selection into confirmatory testing under one protocol. This can shorten development timelines and reduce the number of patients needed. These designs also raise questions that FDA reviewers examine closely: how the dose carried forward was chosen, whether the adaptation rules were fixed in advance, and whether the familywise type I error rate is still controlled after the selection step. Regulatory and clinical teams planning a seamless program need to know where FDA has accepted these designs and on what terms.

The analysis below reviews FDA's adaptive design guidance and approved drug and biologic programs in Drugs@FDA and CBER review files that used seamless Phase 1/2 or Phase 2/3 designs. For each precedent it covers what reviewers asked for on dose selection, prespecified adaptation rules, operational bias and type I error control. It also separates operational seamlessness, where one protocol runs across stages, from inferential seamlessness, where data from both stages are pooled in the confirmatory analysis.

Rhizome is an AI regulatory coworker that researches 143 health authority databases, and cites a specific page for each claim. Create a free account to ask it questions or have your agents search its databases.Connect it to your Claude or ChatGPT for free to ask it questions or have your agents search its databases.

FDA acceptance of seamless Phase 1/2 and Phase 2/3 designs: precedents and reviewer requirements

FDA has accepted seamless designs in drug and biologic programs when the dose-selection stage, the adaptation rules and the confirmatory inference were planned in advance and protected from operational bias. The review record shows a consistent pattern. FDA is generally willing to let one protocol carry a program from dose finding into confirmation. What it negotiates is which patients count toward confirmatory efficacy, how the selected dose was chosen, and how the familywise type I error rate survives the selection step.

Key takeaways

  • FDA's final adaptive design guidance (November 2019) states that seamless designs combining dose selection and confirmation of efficacy using data from the entire trial "can be considered," provided its adaptive-design principles are followed 275276.
  • Accepted Phase 2/3 precedents in Drugs@FDA and CBER review files include sarilumab (KEVZARA), dulaglutide (TRULICITY), propranolol oral solution (HEMANGEOL), risdiplam (EVRYSDI), nivolumab/relatlimab (OPDUALAG) and the 9-valent HPV vaccine (GARDASIL 9) 23262776669297150.
  • FDA often accepted the operational seamlessness while limiting the inferential seamlessness. For TRULICITY it treated only Stage 2 as confirmatory 75, and for KEVZARA it excluded the pre-selection Part B cohort from efficacy analyses 229230.
  • Where stages were combined inferentially, reviewers expected a prespecified testing method that accounts for the selection step and controls multiplicity. HEMANGEOL used a weighted inverse-normal combination function with Simes adjustment and closed testing 330334.
  • Recurring reviewer requests: prespecified selection rules and simulations, a single endpoint for selection and confirmation (STELARA proposal), a broad enough dose range, firewalls documenting "who knows what," and justification for pooling stages 872401019695.

What FDA guidance says

Adaptive design guidance (final, 2019)

The Adaptive Designs for Clinical Trials of Drugs and Biologics guidance addresses seamless designs under "Adaptations to Treatment Arm Selection," not as a separate Phase 2/3 category 275276. It distinguishes adaptive dose-ranging intended to pick doses for a future confirmatory trial from in-trial arm selection intended to provide substantial evidence of effectiveness 277. Its central requirements are:

  • Prospective specification of both the treatment-arm selection rule and the testing method, along with rules for any other interim modification 275281.
  • Testing that accounts for selecting the best dose(s) from several evaluated doses and for additional adaptations such as early stopping or sample-size changes. Group-sequential methods can be combined with a multiple-testing approach that controls type I error across doses 275285.
  • Limiting access to comparative interim results and ensuring timely, reliable interim data 288289.
  • Use of analytical methods that avoid biased estimates, with simulations often critical for complex designs 294.
  • Unplanned changes based on comparative interim results can undermine type I error control and are strongly discouraged without first meeting FDA 284.

ICH E20 draft (September 2025)

The draft E20 Adaptive Designs for Clinical Trials guidance, section 4.4 "Treatment Selection," describes selecting one or both doses at interim and assessing efficacy and benefit-risk using both stages. Planning should specify the treatments, interim decisions, anticipated selection rules, effects on randomization and sample size, and management of participants on a discontinued treatment 249. Sponsors should ensure interim estimates support reliable selection, including appropriate interim timing 278. E20 generally recommends statistical methods that allow departure from the anticipated selection rule so the full interim information can inform the decision 282283. It also warns that selecting treatments with more favorable interim results biases conventional end-of-trial estimates, and that sponsors should consider adjusted estimates 292293. Operationally, it calls for limiting what can be inferred from interim analyses and for prespecified randomization algorithms with minimal sponsor involvement 256.

Oncology dosage optimization (final, August 2024)

The Optimizing the Dosage of Human Prescription Drugs and Biological Products for the Treatment of Oncologic Diseases guidance describes a "seamless approach" with rapid transitions from dose finding to registration trials and states that, with sufficient planning, dosage optimization can be aligned with expedited development 16. A registration trial comparing multiple dosages with a control should provide strong control of type I error, with a multiple-testing procedure covering both the multiple treatment comparisons and the interim assessments at which inferior arms are dropped 286. Dosage-arm enrollment may be stopped at interim after review of activity and/or safety, and selection should compare exposure, dose interruptions and reductions, discontinuations and serious adverse reactions across dosages 279280. Inadequately justified dose selection can raise clinical-hold concerns 9.

Expansion cohorts in first-in-human oncology trials (final, March 2022)

For Phase 1/2-style programs, the Expansion Cohorts: Use in First-in-Human Clinical Trials to Expedite Development of Oncology Drugs and Biologics guidance describes concurrently accruing cohorts that assess safety, pharmacokinetics and antitumor activity within a single FIH trial 1328. It covers drug characteristics suited to the approach, the information needed to support each cohort, and when to interact with FDA 3038. The separate master protocols guidance explicitly excludes FIH expansion-cohort trials from its scope 3132.

A related note for device-adjacent readers: FDA's 2016 device adaptive design guidance explicitly permits inferentially seamless feasibility-to-pivotal studies if the combination plan precedes unblinded access to feasibility data and controls overall type I error across both stages. That is device guidance, not a drug or biologic rule 287.

Phase 2/3 precedents in FDA review records

Product (application)TrialSeamless structureDose selectionType I error / inference approachFDA position
KEVZARA, sarilumab (BLA 761037)EFC11072Operationally seamless Phase 2/3: Part A dose ranging, Part B confirmation without recruitment interruption 225226Six-arm Part A; 150 mg and 200 mg q2w selected on efficacy and safety 227319Only Part B Cohort 2 in efficacy ITT; Bonferroni across two doses, hierarchical testing at α = 0.025 per dose 320321323FDA agreed to the design, subject to excluding Cohort B1 from efficacy 232229
TRULICITY, dulaglutide (BLA 125469)GBCFAdaptive dose-finding, "inferentially seamless" Phase 2/3 235Bayesian adaptive allocation across seven doses using a clinical utility index; 1.5 mg and 0.75 mg selected 235236FDA would treat only Stage 2 as confirmatory because of selection bias 75Clinical reviewer: dose-selection process "seems acceptable" 351
HEMANGEOL, propranolol (NDA 205410)Study 201Two-stage adaptive seamless Phase II/III 77IDMC selected 3 mg/kg/day for 6 months from four regimens 332333Weighted inverse-normal combination of stage p-values, Simes adjustment, one-sided ≤0.005; closed testing for key secondary 330334Clinical and statistical reviewers agreed data supported approval 81
EVRYSDI, risdiplam (NDA 213535)FIREFISH, SUNFISHTwo-part "operationally seamless" Phase 2/3 studies 6669Part 1 dose escalation selected the Part 2 dose 66223For the original 2020 approval, FDA based SUNFISH efficacy on Part 2 and FIREFISH efficacy on Part 1 71Efficacy determinations made on the stated parts 7168
OPDUALAG, nivolumab/relatlimab (BLA 761234)CA224047Adaptive Phase 2/3 with prespecified PFS HR ≤0.8 gate to full Phase 3 212297Not a dose-selection design; Phase 2 to Phase 3 go decision on DMC recommendation 297Phase 2 participants included in Phase 3 analyses; stage-wise alpha allocation not detailed in the cited review pages 297295FDA called the trial well designed and well conducted 106107
GARDASIL 9, 9vHPV vaccine (BLA 125508)V503-001Seamless Phase IIb/III adaptive design 149150Part A compared three formulations on immunogenicity; one carried into Part B 122151Final one-sided alpha 0.0247 for GMT noninferiority, analogous to spending ≤0.001 at interim (Haybittle-Peto) 152Reviewer noted sponsor trial staff did not see unblinded Part A data; blinding preserved 155

KEVZARA: operational seamlessness without pooled inference

EFC11072 moved from Part A (Phase 2 dose ranging) into Part B (Phase 3) without a recruitment pause, and the clinical reviewer classified it as not an adaptive design: Part A was the learning stage, Part B the confirmatory stage 226318. Part A patients did not enter Part B 227. Because Part B enrollment began before dose selection, Cohort 1 was initially randomized across all six arms; patients on unselected doses were discontinued after selection 228320. FDA required that Cohort 1 be excluded from efficacy and retained for safety, and the pivotal efficacy population was Cohort 2's 1,197 randomized patients 229230322. The dose rationale combined efficacy across four regimens with dose-related discontinuations and neutrophil reductions, favoring the lowest effective regimen plus 200 mg q2w 319. Familywise error was held at two-sided 5% using a Bonferroni split across doses and a four-step endpoint hierarchy 323324.

TRULICITY: a Bayesian selection stage treated as exploratory

GBCF used adaptive allocation and Bayesian predictive probabilities across seven weekly doses (0.25 to 3.0 mg), with selection driven by a clinical utility index combining HbA1c, weight, diastolic blood pressure and heart rate 235. The decision point was data-driven rather than calendar-fixed 73. A lower dose had to have acceptable utility and be ≤50% of the maximum-utility dose 236. At FDA's recommendation, a second, lower dose was carried forward in case a safety signal emerged at the maximum-utility dose 62. Although the sponsor's analyses pooled both stages, FDA had stated in January 2008 correspondence that it would consider only Stage 2 confirmatory and Stage 1 exploratory because of potential selection bias 7375.

HEMANGEOL: a full inferentially seamless design and the questions it raised

Study 201 is the clearest example in the record of a sponsor-planned stage-combined confirmatory analysis. The interim analysis was planned after 40 patients per active regimen and 20 placebo patients completed Week 24, with one or two regimens allowed to advance 330331. Stage 1 and Stage 2 p-values were combined with a weighted inverse-normal function, Simes' method adjusted the Stage 1 p-value, and type I error was held at one-sided ≤0.005 330. Patients already on unselected regimens stayed on treatment but were excluded from the primary analysis 338.

During IND review, FDA asked whether controlling error conditional on selecting one versus two doses would control the unconditional study-wise error rate, requested a detailed multiplicity plan, and asked what could be claimed if primary and key secondary endpoints succeeded at different doses 185. Reviewers also questioned the ambiguous "best regimen" rule, how IDMC clinicians would resolve disagreements, why a second regimen might be selected, and why randomization ratios were not prespecified 182183. They requested the timing and rules for any second-stage sample-size increase and firewall procedures 184. At the NDA stage, the clinical reviewer observed that randomization to all five arms had finished before the January 2012 interim meeting and questioned whether a seamless adaptive design had been necessary at all 79. FDA's statistical reviewer likewise said that, because all five arms were fully randomized before the interim analysis, the trial should be analyzed as a conventional five-arm parallel trial with an unblinded interim analysis, and noted that differential dropout probably left the nominal p-value overstating the strength of evidence. Reviewers nonetheless agreed the data supported approval 81.

GARDASIL 9: a seamless vaccine program at CBER

V503-001 randomized about 1,240 subjects in Part A across three 9vHPV formulations and the quadrivalent control, then selected one formulation on interim immunogenicity for Part B's approximately 13,380 subjects 122. Part A subjects on the selected formulation or control continued into the efficacy substudy 123151. The statistical reviewer recorded that Merck personnel involved in trial conduct did not view unblinded Part A data during selection, so selected-dose and control participants could continue into Phase III without compromising blinding 155. Alpha for the Part B GMT noninferiority test was adjusted to a nominal one-sided 0.0247 to account for the interim look 152.

Phase 1/2 and Phase 1/2/3 designs

The review record for combined Phase 1/2 trials looks different from Phase 2/3. These trials are usually single-arm oncology or cell and gene therapy studies, and FDA's comments focus on dose rationale and interpretability rather than familywise error control.

  • COMIRNATY (BLA 125742): Study C4591001 was explicitly Phase 1/2/3, testing 10, 20 and 30 µg in Phase 1 and carrying 30 µg into Phase 2/3 442.
  • BREYANZI (BLA 125714): Study 017001 was described by the statistical reviewer as a "seamless designed, Phase 1 study," with dose finding, dose escalation/expansion, and dose confirmation at the regimen selected by a Steering Committee using a modified continual reassessment method 159161162. The 100 × 10⁶ CAR+ T-cell dose was chosen from cumulative efficacy and safety data 434.
  • EPKINLY (BLA 761324): GCT3013-01 was a Phase 1/2 dose escalation and expansion trial, and FDA based its core efficacy assessment on the expansion cohort 383393. FDA described the evidence as open-label, multi-cohort and single-arm 384.
  • JIDEYTRO (NDA 220185): ARROS-1 combined BOIN dose escalation, expansion at candidate RP2Ds and Phase 2 cohorts; FDA used patients treated at 100 mg once daily as its primary efficacy population 380386. FDA noted that in a single-arm trial efficacy is judged on response magnitude, precision and duration rather than inferential testing 397.
  • BEQALZI (NDA 220711): Study 201 was reviewed as a pivotal Phase 1/2 study with dose escalation and safety expansion in Part 1 and efficacy expansion in Part 2; the safety monitoring committee determined the RP2D from Part 1 data 387389.
  • AUGTYRO (NDA 218213): for TRIDENT-1, described in a sponsor question as "registrational Phase 1/2," FDA requested that all dosed Phase 1/2 patients be included in ORR analyses and reserved judgment on which cohorts supported approval 404.

The review pages cited here for these programs do not contain explicit FDA findings on dose-selection adequacy or postmarketing dose-optimization requirements. Readers evaluating a Phase 1/2 registrational strategy should review the full clinical pharmacology and multidisciplinary reviews for each product.

What FDA reviewers required

Dose selection

  • Same endpoint for selection and confirmation. In a ustekinumab (STELARA) seamless proposal, Part 1 would select doses on Week 6 CDAI change while Part 2 confirmed on Week 6 clinical response; FDA recommended a single endpoint for both 240. FDA also questioned whether time savings remained once pre-selection Part 2 patients were excluded, and suggested separate Phase 2 and Phase 3 studies 241242243.
  • Adequate dose range and prespecification before the learning stage. For resmetirom (REZDIFFRA), FDA rejected a dose rationale because Phase 2 had not identified an optimal dose, considered 80 to 100 mg too narrow, and offered a seamless Phase 2b/3/4 study as an alternative only if the entire SAP was specified before Phase 2b began 101102.
  • Hedge doses. FDA asked that TRULICITY carry a lower dose forward in case of a safety signal at the maximum-utility dose 62.
  • Dose optimization before registration in oncology. For iberdomide (ZENBEXUS), FDA raised concerns at a September 2021 meeting about a proposed 1.6 mg dose and recommended further dose optimization 345. The sponsor redesigned CC-220-MM-002 from a single-stage Phase 3 into a two-stage inferentially seamless design in which Stage 1 compared 1, 1.3 and 1.6 mg and the IDMC selected 1 mg as the recommended Phase 3 dose 343354355.

Adaptation rules and documentation

  • For the methylnaltrexone (RELISTOR) seamless Phase 2/3 proposal, FDA said acceptability could not be judged without a detailed SAP that set explicit criteria for each adaptation, explained familywise type I error control and supplied simulation results 87. It also requested a flowchart of the adaptations and rules, DMC charter and SAP, and documented firewalls between the sponsor, DMC and external statistical center 88181. FDA questioned why sponsor non-project clinicians and statisticians needed to join DMC dose-selection deliberations 86.
  • For HEMANGEOL, FDA asked for a clear "best regimen" definition and prespecified randomization ratios for the confirmatory stage 182183.

Type I error control and pooling of stages

FDA handled the selection-stage data in three ways:

  1. Exclude pre-selection data from confirmatory efficacy. This applied to TRULICITY Stage 1 75 and KEVZARA Part B Cohort 1 229321, and, in a proposal, STELARA's pre-selection Part 2 patients 241.
  2. Combine stages with a prespecified adaptive test. HEMANGEOL used an inverse-normal combination function with Simes and closed testing, and FDA probed whether unconditional study-wise error was controlled 330334185.
  3. Pool with justification and stage-specific sensitivity analyses. For ZENBEXUS, FDA required justification for pooling, comparison of demographics and baseline characteristics before versus after dose selection, and separate efficacy analyses by enrollment stage 95. FDA's assessment reported a one-sided type I error of 0.005 for the MRD-negative CR endpoint 246.

Alpha recycling across phases also drew scrutiny: in the REZDIFFRA proposal, FDA warned that failure of any hierarchically tested Phase 3 key secondary endpoint would mean that Phase 3 alpha could not be recycled to Phase 4 primary endpoints 103.

Firewalls and interim data access

FDA consistently tied acceptability to documented information control. For ZENBEXUS, unblinding the study team to the Stage 1 dose-justification package was reasonable only with an adequate firewall against unintended efficacy unblinding and prespecified documentation of who would know what 96. GARDASIL 9's reviewer specifically recorded that sponsor trial staff were walled off from unblinded Part A data 155. The 2019 guidance and E20 draft treat this as a core design element, not an operational detail 288256.

Practical implications for sponsors

  • Decide early whether the design is operationally or inferentially seamless. The precedents show FDA readily accepting operational seamlessness (KEVZARA, EVRYSDI) and expecting, for inferential seamlessness, a prespecified testing method that accounts for dose selection (HEMANGEOL's combination test) and, for complex designs, simulation results (RELISTOR) 2327133087.
  • Expect FDA to ask whether the seamless design actually saves time once excluded cohorts are accounted for 24224379.
  • Write the selection rule, the selection endpoint, the number of doses that may advance and the randomization ratio after selection into the protocol and SAP before the first interim look 275281183240.
  • Plan for estimation bias in the selected arm, not only type I error control 292293294.
  • In oncology, align the seamless dose-selection stage with the 2024 dosage optimization guidance, including strong type I error control when multiple dosages enter a registration trial 286279.
Rhizome is an AI regulatory coworker that researches 143 health authority databases, and cites a specific page for each claim. Create a free account to ask it questions or have your agents search its databases.Connect it to your Claude or ChatGPT for free to ask it questions or have your agents search its databases.