Master protocols let a sponsor test one drug across several diseases, or several drugs within one disease, under a single shared infrastructure. They are now common in oncology and increasingly used elsewhere. For regulatory and clinical teams, the open question is less whether FDA accepts these designs and more how reviewers weigh the evidence they produce. Reviewers look at single-arm cohorts, pooled analyses, shared controls and small subgroups when deciding whether a master protocol can support approval and labeling.
The analysis below covers FDA drug and biologic approvals that relied on basket, umbrella or platform trials, in oncology and beyond. It draws on review documents, labeling and FDA's master protocol guidances. It sets out how FDA defines each design, which approvals used them, and what reviewers recorded as the strengths and limitations of the designs in those files.
FDA approvals based on basket, umbrella and platform trials: what reviewers said about master protocol designs
Master protocols have supported a distinct set of FDA approvals. Most of the examples reviewed here are in oncology, where single-arm basket cohorts have supported tissue-agnostic and tumor-specific accelerated approvals. Outside oncology there are several high-profile examples: the PALM Ebola master protocol, the SURMOUNT-OSA "basket-type" master protocol for tirzepatide, and the RECOVERY platform study cited in tocilizumab labeling. Umbrella designs appear in the records reviewed only in a supportive role (Litfulo). Across these files, FDA reviewers have consistently credited the designs with efficiency, biological coherence and feasibility in rare populations. They have just as consistently pointed to the same weaknesses: single-arm data that cannot interpret time-to-event endpoints, sparse tumor-type representation, unreliable subgroup estimates, pooling that can undercut independent substantiation, and shared-control choices that complicate interpretation.
How FDA defines the designs
FDA's March 2022 final oncology guidance, Master Protocols: Efficient Clinical Trial Design Strategies to Expedite Development of Oncology Drugs and Biologics, and the June 2026 cross-therapeutic draft, Master Protocols for Drug and Biological Product Development, set out the working vocabulary 599582602:
- Basket trial: one drug evaluated across multiple diseases, conditions or disease subtypes 603. In oncology, the populations can differ by cancer, stage, histology, prior therapy, biomarker or demographics 604.
- Umbrella trial: multiple drugs evaluated concurrently in a single disease or condition 605606.
- Platform trial: an ongoing trial of multiple drugs for one or more diseases, with drugs entering or leaving the platform 607. A platform can include both basket and umbrella components, so the categories overlap 608.
The guidance also addresses issues that reviewers raised in individual applications. A common control arm should reflect current standard of care, and enrollment should be suspended if that standard changes 609. Primary comparisons should generally use only concurrently eligible controls 587. Multiple groups invite overinterpretation, including false apparent subgroup differences 611. Basket substudies are usually single-arm, ORR-based and need their own sample-size justification and stopping rules 613.
Approvals at a glance
| Product (application) | Trial and design as described in the FDA record | Role in approval |
|---|---|---|
| Keytruda (BLA 125514), MSI-H/dMMR solid tumors | Five pooled single-arm trials (KEYNOTE-016, -012, -028, -164, -158), 149 patients, 16 tumor types in the review's analysis dataset (FDA's approval announcement counts 15) 665666281 | Primary efficacy, first site-agnostic approval 154 |
| Keytruda (BLA 125514, S-34), cervical cancer | KEYNOTE-158, "multicohort (basket)" study, Cohort E 33 | Sole efficacy trial 34 |
| Keytruda, TMB-H solid tumors | KEYNOTE-158, retrospective analysis of 10 cohorts (A to J) 507 | Accelerated approval on response rate and durability 569 |
| Vitrakvi (NDA 210861, 211710), NTRK fusion solid tumors | Three single-arm trials, including LOXO-TRK-15002, an open-label basket study 4950 | Primary efficacy, pooled (efficacy N=55) 148 |
| Rozlytrek (NDA 212726), NTRK fusion solid tumors | Three single-arm trials including STARTRK-2, a phase 2 basket study 18238 | Primary efficacy, pooled (efficacy N=54) 184 |
| Rozlytrek (NDA 218550), pediatric NTRK expansion | STARTRK-NG and TAPISTRY, a multi-cohort genomically selected study 471473 | Primary efficacy, pooled (N=33) 471 |
| Retevmo (NDA 213246, S-8), RET fusion solid tumors | LIBRETTO-001 tissue-agnostic analysis sets (45 safety, 41 efficacy) 132 | Primary efficacy, accelerated approval 136 |
| Jemperli (BLA 761223), dMMR solid tumors | GARNET Cohorts A1 and F, 209 patients 621 | Primary efficacy, accelerated approval 625 |
| Enhertu (BLA 761139, S-28), HER2 IHC 3+ solid tumors | Data from DP-02, DL-01, DC-02, DB-01 and DG-02 in the review; FDA's approval notice bases efficacy on DP-02, DL-01 and DC-02 (192 patients) 166 | Multi-study tissue-agnostic package 167 |
| Zepzelca (NDA 213702), SCLC | Study B-005, single-arm, multi-cohort basket trial 69 | Primary efficacy, accelerated approval 704708 |
| Trodelvy (BLA 761115), mTNBC | IMMU-132-01, phase 1/2 basket trial with expansion cohorts 329 | Sole efficacy trial, accelerated approval 540 |
| Zelboraf (NDA 202429, S-16), Erdheim-Chester disease | VE-BASKET (MO28072), Cohort 7a, 22 ECD patients 64571 | Primary efficacy 574 |
| Inmazeb (BLA 761169), Ebola | PALM, master protocol with shared ZMapp control 224 | Primary efficacy, traditional approval 370 |
| Ebanga (BLA 761172), Ebola | PALM 371 | Primary efficacy and safety 371372 |
| Zepbound (NDA 217806, S-13), OSA | SURMOUNT-OSA (GPIF), "basket-type master protocol" with two independent trials 220221 | Two adequate and well-controlled trials 430 |
| Actemra (BLA 125276 intravenous, shared labeling with BLA 125472), COVID-19 | RECOVERY, randomized, controlled, open-label platform study 451454 | Labeling states COVID-19 efficacy "was based on RECOVERY" 451454 |
Tissue-agnostic approvals built on pooled basket evidence
Pembrolizumab for MSI-H/dMMR cancers
The MSI-H/dMMR review describes the first approval independent of cancer type and based solely on a tumor biomarker 154. Reviewers justified pooling five trials, two doses and 16 tumor types on the basis of consistent demographic and baseline characteristics and consistent response rate and durability across trials 281305. The team leader considered the evidence substantial because durable objective responses, confirmed by independent radiology review, were seen across multiple trials, multiple MSI-H/dMMR cancers and sites in and outside the United States 668.
Reviewers were direct about the limitations:
- The protocols contained no sample-size justification, and all studies were ongoing. Decisions would rest on the ORR point estimate and 95% CI, not formal hypothesis testing 671.
- Between-trial differences could reflect chance, population, site or design rather than dose, given the nonrandomized design and limited numbers 672.
- Tumor-specific results "may not be reliable" because of sample size. Their value was in showing breadth across tumor types, not in establishing efficacy in each cancer 673.
- The reviewer warned that this approval should not imply that every biomarker-targeted drug merits a site-agnostic indication, because tumor-specific resistance mechanisms and treatment context could alter benefit 674.
Larotrectinib and entrectinib for NTRK fusion-positive tumors
The NTRK reviews follow the same template. For larotrectinib, FDA identified limited efficacy numbers (N=55) and a small safety population (N=176), with patients enrolled sequentially across multiple single-arm trials, as review challenges 148. Strong scientific rationale, nonclinical evidence and consistent durable shrinkage across tumors and fusion partners justified pooling 149. FDA accepted that effects in underrepresented tumors, including lung and colon cancers, were less well characterized, and required additional evidence because of the many histologies and the small efficacy database 150151. It also cautioned that limited exploratory subgroup sizes prevented interpretation of numerical ORR differences across tumor types and fusion subgroups 286311. Reviewers further noted that response rate and duration might not fully capture benefit, citing complete radiographic disappearance and limb-sparing surgery in some patients 180.
The entrectinib review (NDA 212726) repeats these points. Small efficacy (N=54) and safety (N=355) populations were limitations 184. Pooling was warranted by biological rationale, nonclinical activity across cell lines and fusion partners, and consistent durable shrinkage 186. Effects in pediatric and CNS cancers were less well characterized 187, and postapproval data were needed to improve confidence across tumor types 188. Reviewers also explained why randomization was not the answer: extreme rarity, differing natural histories, limited equipoise and expected crossover made randomized trials challenging, and combining all tumor types in one randomized trial might not be scientifically appropriate 189.
In the 2023 pediatric expansion (NDA 218550), reviewers said the two single-arm trials were pooled "due to the rarity of the population" 474. They reported prespecified analyses, no major statistical issues and BICR to minimize measurement bias 475476. They noted that the small population made it hard to tell whether response differed between CNS and non-CNS tumors 479, and attached a postmarketing requirement to verify benefit 480.
Selpercatinib, dostarlimab and trastuzumab deruxtecan
For selpercatinib's RET fusion tissue-agnostic indication, FDA acknowledged variable response rates in tumor-specific groups of 1 to 11 patients. It still considered the indication appropriate given clinically meaningful responses across tumor types and the existing NSCLC and thyroid cancer evidence 134. Reviewers flagged uncertainty about response magnitude in extremely rare or unrepresented tumors and the lower colorectal response rate, and required additional cross-tumor evidence postmarketing 135. A randomized trial was considered infeasible 136. Enrollment that was 63% U.S.-based supported applicability to the U.S. population 137.
For dostarlimab, FDA reported a BICR-confirmed ORR of 41.6% across 209 patients 621. It also noted 15 tumor types, some represented by only one or two patients 625. Before submission, FDA had warned that most of approximately 200 patients had endometrial or colon cancer, with only about 30 having other tumor types 129. Confirmatory evidence was therefore to come from at least 300 patients with representation beyond endometrial and gastrointestinal tumors 625.
For trastuzumab deruxtecan, FDA stated that DP-02 alone included too few tumor types to support an agnostic indication, because tumors studied separately (NSCLC, gastric and colorectal) were excluded. FDA also noted the mismatch between the 6.4 mg/kg gastric dose and the proposed 5.4 mg/kg agnostic dose 168. The multi-study IHC 3+ dataset was acceptable to support filing 166. FDA separately analyzed a three-trial pool so that breast cancer patients from DB-01 would not mask safety signals 288. It found safety consistent across tumor types because patients, despite differing histologies, were in similar prior-therapy settings 291.
When FDA declined a tissue-agnostic claim
Zenocutuzumab (Bizengri, BLA 761352) shows the limit of the approach. FDA found the eNRGy tissue-agnostic package inadequate. NSCLC and pancreatic adenocarcinoma made up over 78% of every analysis population, and confirmed responses occurred in only four of eight tumor types 161191. FDA cited differing response magnitudes across tumor types 162. It also said heterogeneous prior treatment prevented a judgment on whether NSCLC response rates improved on available therapy 163, and advised excluding expanded-access patients from the primary pooled analysis because of potential heterogeneity 164. FDA allowed tissue-agnostic development to continue in eNRGy for a possible future application 159.
Tumor-specific approvals from a single basket cohort
Several approvals relied on one disease cohort within a basket trial. Here the reviewer commentary concerns single-arm inference more than cross-tumor pooling.
- Keytruda, cervical cancer (KEYNOTE-158 Cohort E): Reviewers described an adaptive basket trial with ongoing review of accrual and potentially multiple interim analyses 323. No power calculations were built into the overall design 736. FDA did not integrate KEYNOTE-028 data because trial designs, doses and populations differed 34. The statistical review stated that "no inferential procedures were used to evaluate results from this single arm study," that efficacy rested on response magnitude and duration, and that "time-to-event endpoints are uninterpretable without a comparator arm" 735. Patient characteristics were considered generalizable to the U.S. population despite largely international enrollment 32.
- Zepzelca, SCLC (Study B-005): The single-arm basket trial was the primary efficacy evidence 69. FDA found investigator and IRC response results consistent 699 and accepted response rate as an endpoint because such shrinkage would not occur without therapy 701. Earlier, FDA had said the cohort would not support accelerated approval, citing a small platinum-resistant subgroup and a CI lower bound below 12% 706707. PFS and OS were "uninterpretable without a comparator arm" 705, and continued approval depended on a confirmatory trial 708.
- Trodelvy, mTNBC (IMMU-132-01): Reviewers accepted an ORR of 33.3% with median DOR of 7.7 months in 108 patients 539, with no notable statistical issues 541. They cautioned that central review covered only selected responders (n=55) 544. FDA had earlier rejected a 31-patient cohort as insufficient on its own 545.
- Zelboraf, Erdheim-Chester disease (VE-BASKET): The application rested primarily on ORR from a single-arm, open-label, nonrandomized phase II trial with 22 ECD patients 574575. The Division agreed that no ECD companion diagnostic was needed because of the disease's rarity, with local BRAF V600 testing permitted 65572. PK appeared similar across melanoma, NSCLC and ECD 64.
Master protocols and platform trials outside oncology
PALM: Inmazeb and Ebanga
The PALM review gives FDA's clearest explicit statement on the value of master protocols. Under "Trial Design," reviewers listed the advantages: evaluating multiple treatments against a shared active investigational control, adding or removing arms, reducing sample size, and using common infrastructure with consistent data collection 224. On multiplicity, reviewers acknowledged there is no statistical consensus, but noted the view that each treatment-versus-control comparison can be considered a separate trial 224. Because the three investigational products belonged to different sponsors, and no sponsor had multiple chances to "win," no multiplicity adjustment was considered necessary 402.
The main limitation reviewers identified was the comparator. Using investigational ZMapp rather than optimized standard of care alone raised interpretability concerns 403. The master protocol allowed either control, and the DRC selected ZMapp plus oSOC 404. The trial was open-label, and two randomization block sizes were used to reduce selection bias 401. The DSMB stopped assignment to ZMapp and remdesivir after an interim analysis showed superiority of REGN-EB3 and mAb114 406374. The Inmazeb reviewer reported a 17.2 percentage-point reduction in 28-day mortality versus ZMapp (33.8% vs 51.0%), following a prespecified stopping criterion 375. FDA considered the dose "demonstrated to be effective in comparison to the active control" 410. The Ebanga team found no issues in assessing superiority over ZMapp 372 and judged trial conduct adequate 379. FDA also noted that the absence of PK sampling in infected PALM participants prevented exposure-response analysis 223.
SURMOUNT-OSA: Zepbound
FDA called GPIF a "basket-type master protocol" supporting two independent randomized, placebo-controlled trials, GPI1 (no PAP) and GPI2 (on PAP) 220221. Each trial had its own placebo group 422. FDA had recommended two adequate and well-controlled trials, and the applicant confirmed there would be no shared placebo and no pooled efficacy analysis 423. FDA agreed in January 2024 that efficacy would not be pooled 425. The April 2024 SAP nevertheless pooled the PROMIS PRO key secondary endpoints across the intervention-specific appendices 426.
Reviewers rejected that pooling for two reasons. Baseline PAP use could confound PRO assessment, and pooling a key endpoint was inconsistent with independent substantiation from more than one investigation 427. The separate-trial PRO results were therefore treated as exploratory, outside the multiplicity hierarchy 428429. The Division Director still described GPI1 and GPI2 as two adequate and well-controlled trials providing substantial evidence of effectiveness 430. For sponsors, the lesson is that a shared master protocol can deliver two independent pivotal trials, but FDA would not accept pooling the key PRO endpoints across them.
RECOVERY: tocilizumab
Actemra labeling shared by BLA 125276 (intravenous, the COVID-19 formulation) and BLA 125472 states that COVID-19 efficacy "was based on RECOVERY," a randomized, controlled, open-label platform study, with EMPACTA as support 451454. The control was standard of care alone, the primary endpoint was time to death through Day 28, and 82% of patients were on systemic corticosteroids at baseline 457458459. RECOVERY data also appear in the Tofidence and Avtozma biosimilar records 455456. The FDA review documents cited here do not contain reviewer commentary on RECOVERY's open-label design or usual-care control.
Comirnaty
CBER reviewers relied on Substudies A and C of C4591031, "A Phase 3 Master Protocol To Evaluate Additional Dose(S) Of BNT162b2," as supportive safety and immunogenicity data for a third dose 339340. Only two of six substudies were presented, with limited follow-up 341. The cited passages contain no design-specific appraisal.
Supportive rather than pivotal use
Master protocols also appear in approval packages in secondary roles:
- Lumakras (NDA 214665, S-9): Study 20190135, a phase 1b master protocol, contributed cross-tumor integrated safety data. The pivotal study was the separate randomized Study 20190172 227229319.
- Litfulo (NDA 215830): B7931005, footnoted as an "umbrella trial design" testing brepocitinib and ritlecitinib, supported lymphocyte-count modeling 101102100.
- Ibtrozi (NDA 219713): AB-106-C205, an NTRK basket study, was listed only under studies supporting safety 46.
- Norvir and Viracept: Pediatric HIV master protocols (PACTG 366, a phase I/II master protocol, and the Rolling Arm Master protocols) contributed pediatric PK and screening data 236243.
What FDA said about a proposed platform trial
The Talvey (BLA 761342) record contains FDA's most detailed critique of a platform design, though the trial was proposed and is not shown to have supported approval 38470. FDA generally agreed with the master-protocol approach 384 but raised these concerns:
- Operational complexity could cause miscommunication that compromises patient safety, so FDA recommended a dedicated IND 386.
- The control must reflect current U.S. standard of care, with enrollment suspended if that standard changes 387.
- Comparisons across enrollment periods could introduce bias even with stratification by time 388.
- Adding arms could change control-arm sample-size requirements and eligibility, and FDA asked for plans to handle this 389.
- Multiple hypotheses tested against one control raise study-wide multiplicity concerns that could weaken registration evidence 390391.
Recurring reviewer themes
Strengths FDA credited
- Efficiency through shared infrastructure, shared controls and the ability to add or drop arms 224.
- Feasibility in rare, molecularly defined populations where randomization is impractical or inappropriate 189136474.
- Strong biological rationale and consistent, durable responses across histologies as the basis for pooling 149186305.
- Response rate as an interpretable endpoint because tumor shrinkage is not expected without treatment 701668.
- BICR and prespecified analyses to limit measurement bias in single-arm cohorts 475476.
Limitations FDA flagged
- No inferential testing, and time-to-event endpoints uninterpretable without a comparator 735705543.
- Missing sample-size or power justification 671736.
- Sparse or skewed tumor-type representation and unreliable subgroup estimates 625673134161.
- Pooling that conflicts with independent substantiation or mixes heterogeneous populations 427164.
- Shared-control choices (an investigational comparator, changing standard of care, nonconcurrent controls) that affect interpretability 403387388.
- Accelerated approval with postmarketing requirements to broaden tumor coverage or confirm benefit 625135151708.
Open questions for further research
Some reviewer analyses were not found in the documents examined here. These include FDA's review of the BRAF V600E tissue-agnostic approval for dabrafenib plus trametinib (the retrieved Tafinlar records discuss the later pediatric low-grade glioma application) 524526, the review underlying pembrolizumab's TMB-H indication (only labeling text was retrieved) 507, and FDA reviewer commentary on RECOVERY's design. Each is a natural follow-up for teams benchmarking a master-protocol submission strategy.