Paroxysmal nocturnal hemoglobinuria (PNH) is now a crowded therapeutic area. Proximal and terminal complement inhibitors have been approved alongside eculizumab biosimilars, and sponsors planning a new PNH program, a switch study or a biosimilar comparison have to choose a population, a comparator and a primary endpoint that FDA and EMA have already accepted. Precedent on non-inferiority margins, LDH-based hemolysis measures, transfusion avoidance and hemoglobin response shapes how a development plan is designed and how it will be scrutinized in review.
The analysis below covers the pivotal and supportive studies behind each approved complement inhibitor for PNH and its biosimilars. For each product it sets out the design, the population, the comparator and the primary and key secondary endpoints, drawn from FDA and EMA review documents. It also lays out where the two agencies took different positions and which methodological issues reviewers raised, including margin derivation, open-label bias and how patient-reported outcomes were interpreted.
Endpoints and trial designs accepted by FDA and EMA for complement inhibitors in paroxysmal nocturnal hemoglobinuria (PNH)
Complement inhibitors for PNH have been approved on four distinct evidentiary models: (1) placebo-controlled superiority on hemoglobin stabilization and transfusion burden (eculizumab); (2) active-controlled non-inferiority against eculizumab on transfusion avoidance plus an LDH-based hemolysis endpoint (ravulizumab, crovalimab); (3) superiority on hemoglobin-based endpoints in patients with residual anemia on a C5 inhibitor, either as a switch or as add-on therapy (pegcetacoplan, iptacopan, danicopan); and (4) LDH-based comparative clinical studies for eculizumab biosimilars (Bkemv, Epysqli). Both agencies have accepted single-arm and supportive-care-controlled data in complement-inhibitor-naive patients when a randomized pivotal trial carried the program; the single-arm studies served as supportive, not standalone pivotal, evidence. The main points of friction have been non-inferiority margin derivation, open-label bias in transfusion decisions, and the interpretability of LDH and patient-reported fatigue.
Products and pivotal evidence at a glance
| Product (INN) | Mechanism class (as evaluated) | Pivotal / key PNH studies | Population | Design | Primary endpoint(s) |
|---|---|---|---|---|---|
| Soliris (eculizumab) | Anti-C5 | TRIUMPH; SHEPHERD (supportive) | Transfusion-dependent adults | Randomized, double-blind, placebo-controlled, 26 weeks 461462 | Co-primary: Hb stabilization and PRBC units transfused (superiority) 463 |
| Ultomiris (ravulizumab) | Anti-C5 | ALXN1210-PNH-301; ALXN1210-PNH-302 | Naive (301); stable on eculizumab ≥6 months (302) | Randomized, open-label, active-controlled non-inferiority vs eculizumab, 26 weeks 393307 | 301: transfusion avoidance + LDH normalization; 302: LDH % change to Day 183 398385 |
| PiaSky / Piasky (crovalimab) | Anti-C5 | COMMODORE 2 (pivotal); COMMODORE 1 and 3 (supportive) | Naive | Open-label, randomized 2:1 vs eculizumab, non-inferiority, 24 weeks 501689 | Co-primary: transfusion avoidance + hemolysis control (LDH ≤1.5 × ULN) 504509 |
| Empaveli / Aspaveli (pegcetacoplan) | C3 inhibitor | APL2-302; APL2-308 (PRINCE) | Residual anemia on eculizumab (302); naive (308) | 302: open-label superiority vs eculizumab, 16 weeks 316; 308: randomized 2:1 vs supportive care, 26 weeks 84600 | 302: Hb change to Week 16 261; 308: Hb stabilization + LDH change 85601 |
| Fabhalta (iptacopan) | Factor B inhibitor | APPLY-PNH; APPOINT-PNH | Residual anemia on anti-C5 (APPLY); naive (APPOINT) | APPLY: randomized open-label superiority vs continued anti-C5, 24 weeks 538539; APPOINT: single-arm, 24 weeks 111 | Sustained Hb rise ≥2 g/dL and sustained Hb ≥12 g/dL without transfusion 541 |
| Voydeya (danicopan) | Factor D inhibitor, add-on | ALXN2040-PNH-301 | Clinically significant extravascular hemolysis on eculizumab or ravulizumab | Randomized 2:1, double-blind, placebo add-on, 12-week controlled period 587588 | Hb change from baseline to Week 12 589 |
| Bkemv / Bekemv (eculizumab biosimilar, ABP 959) | Anti-C5 biosimilar | Study 20150168 | Stable on eculizumab (per EMA) | Randomized, double-blind, active-controlled, two-period crossover 244211 | FDA: LDH AUEC (crossover) and LDH at Week 27 245; EMA: LDH at Week 27 213 |
| Epysqli (eculizumab biosimilar, SB12) | Anti-C5 biosimilar | SB12-3003 | Treatment-naive (per EMA) | Randomized, double-blind crossover, switch at Week 26 429558 | FDA: LDH AUEC; EMA: LDH at Week 26 430559 |
EU marketing authorization dates in the EPAR record range from Soliris in June 2007 to Piasky in August 2024 5857565460525355. In the US, Voydeya was approved on 2024-03-29 and PiaSky on 2024-06-20 253255.
Model 1: placebo-controlled superiority (eculizumab)
Design. TRIUMPH randomized 87 transfusion-dependent adults to eculizumab (43) or placebo (44) for 26 weeks under double-blind conditions 461462. Eligibility required at least four transfusions in the preceding 12 months, a PNH clone of at least 10%, and platelets of at least 100,000/µL 201. An observation period before randomization established each patient's hemoglobin transfusion "set-point" (≤9 g/dL if symptomatic, ≤7 g/dL if asymptomatic) 463201.
Endpoints. FDA reviewers described co-primary superiority comparisons of (1) the proportion achieving hemoglobin stabilization, defined as remaining above the set-point with no RBC transfusion through 26 weeks, and (2) the number of packed RBC units transfused 463464. Secondary endpoints were transfusion avoidance, LDH area under the curve and FACIT-Fatigue 466. Stabilization occurred in 21/43 versus 0/44 patients and median units transfused were 0 versus 10 (P<0.001 for both) 467465. The EPAR describes the same co-primary structure 720721722.
Reviewer qualifications. FDA did not treat fatigue and quality-of-life findings as a clean independent basis for benefit claims, because quality of life was not reassessed immediately after transfusion and FACIT-Fatigue and EORTC QLQ-C30 validation was questioned 470. Thrombosis analyses were confounded by anticoagulant use 471. The 52-week open-label, single-arm SHEPHERD study was primarily a safety study whose LDH and fatigue data were supportive 472473724725. In the EU, the TRIUMPH design initially limited the conclusion of clinical benefit to patients with a transfusion history. A later CHMP assessment extended benefit to patients with hemolysis and symptoms of high disease activity regardless of transfusion history, while cautioning that LDH alone was not an adequate measure of disease severity 731732733734.
Model 2: active-controlled non-inferiority against eculizumab
Once eculizumab was standard of care, next-generation C5 inhibitors were evaluated against it rather than placebo.
Ravulizumab: different primary endpoints for naive and switch populations
- Study 301 (naive). The co-primary endpoints were transfusion avoidance through Day 183 (no transfusion and no meeting of protocol transfusion criteria) and LDH normalization (LDH ≤1 × ULN, Day 29 to Day 183). Both had to meet non-inferiority 398399. Results were 73.6% versus 66.1% for transfusion avoidance (difference 6.8 points; 95% CI −4.66 to 18.14) and 53.6% versus 49.4% for LDH normalization (odds ratio 1.19; 95% CI 0.80 to 1.77) 303.
- Study 302 (switch). Patients stable on eculizumab for at least six months were randomized to continue or switch. The primary endpoint was percent change in LDH to Day 183, with a 15-point margin 385408. FDA reviewers noted that transfusion avoidance was secondary and LDH normalization was not primary because these patients were already stable and largely transfusion-independent 409. The result was −0.82% versus +8.4% 310.
Margin disputes. The sponsor's margins were −20 percentage points for transfusion avoidance (PNH Registry-based) and an odds ratio of 0.39 for LDH normalization (TRIUMPH-based) 403404405. FDA had warned that 20 points exceeded the largest clinically acceptable difference and recommended no more than 10 points. The statistical reviewer stated that the margins had never been agreed with FDA and questioned the use of point estimates rather than confidence bounds of the historical effect. FDA nevertheless found Study 301 non-inferior under both the sponsor's and FDA's margins 406395407. In Study 302, hemoglobin stabilization did not meet FDA's tighter −10-point margin 410. CHMP also noted that a more conservative TRIUMPH-based derivation (using the lower 95% CI bound) would have yielded an 18.3-point transfusion margin, and that the LDH-normalization margin approach had not been discussed in scientific advice, but did not pursue either point given the results 660661662663. CHMP accepted the 15-point Study 302 margin as preserving 89% of effect, while identifying reliance on registry data alone as a limitation 666667.
Design and endpoint shaping by FDA. FDA objected early that transfusion guidelines alone could bias transfusion avoidance, prompting addition of a prespecified hemoglobin criterion. FDA also objected to LDH percent change as a co-primary endpoint in untreated patients, considering normal or near-normal LDH more meaningful 411412. CHMP considered the open-label design reasonable because the intravenous schedules differed markedly and blinding would have required many sham infusions 670. Both studies failed their first superiority tests, so CHMP concluded similarity rather than superiority 671.
Crovalimab: the same template with tightened margins
COMMODORE 2 randomized naive patients 2:1 to crovalimab or eculizumab for 24 weeks, with co-primary non-inferiority endpoints of transfusion avoidance through Week 25 and hemolysis control (central LDH ≤1.5 × ULN, Weeks 5 to 25) 501502504509. Results were 65.7% versus 68.1% for transfusion avoidance (difference −2.8 points; 95% CI −15.7 to 11.1) and 79.3% versus 79.0% for hemolysis control (odds ratio 1.02; 95% CI 0.57 to 1.82) 444.
- FDA margins. The prespecified margins were −20 points and an odds ratio of 0.20, each intended to preserve half of the estimated eculizumab effect. FDA reviewers rederived them from the lower confidence bound of the TRIUMPH effect, producing −18 points and an odds ratio of 0.33. Both were met (lower bounds −15.7 points and 0.57) 505506507508510511512.
- EMA margins. The −20% transfusion margin matched the ravulizumab precedent and was based on registry comparisons 693. CHMP considered the co-primary endpoints clinically meaningful and discussed and ruled out bias in the investigator-driven transfusion decision 695696697698.
- Bias and missing data. FDA flagged potential transfusion-decision bias in an open-label trial but judged the protocol transfusion guidelines likely to minimize it. FDA found FACIT-Fatigue difficult to interpret and did not include it in labeling 513514. FDA also raised concerns about missing LDH data and the primary GEE analysis, addressed through sensitivity analyses 515516.
- External control and supportive studies. FDA rejected a proposed switch-study design using an external comparator as not adequate and well controlled 520. COMMODORE 1 (switch) stopped enrolment early and its efficacy findings remained exploratory; CHMP accepted the descriptive data as supportive despite uncertainty. COMMODORE 3 was a supportive single-arm study in Chinese patients 699691521.
Model 3: hemoglobin-based superiority in residual anemia (proximal and add-on inhibitors)
Agents targeting C3, factor B and factor D were developed largely in patients with residual anemia on C5 inhibitors, where hemoglobin, rather than LDH, became the primary endpoint.
Pegcetacoplan (C3)
- APL2-302 (switch from eculizumab). In this open-label superiority trial, 41 patients received pegcetacoplan and 39 continued eculizumab for 16 weeks after a four-week run-in. Patients had Hb <10.5 g/dL despite stable eculizumab 316178. The primary endpoint was Hb change to Week 16: +2.37 versus −1.47 g/dL (difference 3.84 g/dL; 95% CI 2.33 to 5.34) 261264332. Non-inferiority was shown for transfusion avoidance and reticulocyte count, but LDH change did not meet non-inferiority, which stopped hierarchical testing before FACIT-Fatigue 33433588.
- CHMP view. CHMP judged the endpoints clinically relevant, with transfusion avoidance particularly important. It called the open-label design of a single pivotal trial a drawback but considered the measures taken to minimize bias sufficient 336337. CHMP also noted baseline imbalances and the exclusion of post-transfusion observations from the primary analysis 338339340.
- APL2-308 / PRINCE (naive). Fifty-three patients were randomized 2:1 to pegcetacoplan or supportive care excluding complement inhibitors for 26 weeks, with crossover permitted on Hb decline of at least 2 g/dL 8486600. The co-primary endpoints were Hb stabilization (no >1 g/dL fall without transfusion), achieved in 85.7% versus 0%, and LDH change, −1,470 U/L between groups 601609610. CHMP accepted the population as representative but noted the open-label design and called supportive care a suboptimal comparator by EU standards 602.
Iptacopan (factor B)
- APPLY-PNH (switch from anti-C5). This randomized, open-label superiority trial enrolled adults with residual anemia (Hb <10 g/dL) despite at least six months of eculizumab or ravulizumab 538539634. Co-primary endpoints were a sustained Hb rise of ≥2 g/dL and sustained Hb ≥12 g/dL, both without transfusion. Hb was assessed at three of four visits on Days 126 to 168 541542. Responses were 82.3% versus 0% and 67.7% versus 0% (p<0.0001) 108543.
- APPOINT-PNH (naive). This single-arm, open-label study enrolled 40 patients with Hb <10 g/dL and LDH >1.5 × ULN 111. The lower 95% CI bound for Hb response was compared with a 15% threshold derived from historical eculizumab data, not with a concurrent control 548639. FDA's statistical reviewer raised concerns about the model assumptions in the prespecified logistic regression for this sample size 549.
- Agency views. CHMP accepted the ≥2 g/dL rise as clinically meaningful and ≥12 g/dL as approximating normalization. It credited guideline-aligned transfusion criteria with reducing bias 642. CHMP treated APPLY-PNH as the pivotal controlled evidence and APPOINT-PNH as supportive, and did not restrict the indication to anti-C5-experienced patients 643616. FDA's statistical reviewer warned that FACIT-Fatigue could be biased by knowledge of treatment in the open-label trial 546.
Danicopan (factor D, add-on)
ALXN2040-PNH-301 was double-blind and placebo-controlled, with danicopan added to ongoing eculizumab or ravulizumab. Patients had clinically significant extravascular hemolysis, defined as Hb ≤9.5 g/dL and absolute reticulocyte count ≥120 × 10⁹/L 587588757. The controlled period lasted 12 weeks, after which placebo patients switched to danicopan 588. At the prespecified interim analysis (n=63), Hb increased by 2.9 versus 0.5 g/dL (difference 2.4 g/dL) 589590. Key secondary endpoints (Hb rise ≥2 g/dL without transfusion, transfusion avoidance, FACIT-Fatigue, reticulocyte count) were tested in a fixed sequence and all favored danicopan 591593.
CHMP accepted the add-on rationale (C5 blockade for intravascular hemolysis, danicopan for residual extravascular hemolysis), the interim analysis timing and alpha-spending, and the sequential testing 756758759. It noted that the lack of a control arm after Week 12 hampered interpretation of long-term efficacy 761762. FDA reviewers noted the program was not designed to assess effects on thrombosis and contained no head-to-head comparisons with pegcetacoplan or iptacopan 594592. The EU indication is restricted to add-on use in adults with residual hemolytic anemia 763. The US indication is likewise add-on to ravulizumab or eculizumab, for extravascular hemolysis in adults with PNH.
Model 4: eculizumab biosimilars (LDH as the comparative endpoint)
Both biosimilar programs used LDH as the sensitive comparative endpoint. The agencies differed on the analysis variable and the margin.
| Aspect | Bkemv (ABP 959) | Epysqli (SB12) |
|---|---|---|
| Design | Randomized, double-blind, active-controlled two-period crossover; 52 weeks then 26 weeks on the other product 244 | Randomized, double-blind crossover, 50 patients, switch at Week 26 429558 |
| FDA endpoint and margin | Time-adjusted LDH AUEC; 90% CI for ratio within 0.77 to 1.30 (FDA recommended 0.77 to 1.29); observed 0.9812 (0.9403 to 1.0239) 245246247248 | Time-adjusted LDH AUEC; 90% CI within 0.77 to 1.29, accepted in place of the conventional 0.80 to 1.25 430431 |
| EMA endpoint and margin | LDH at Week 27, non-inferiority. CHMP found the proposed 2.873-fold margin clinically unacceptable but judged the observed difference not clinically relevant 213 | LDH at Week 26, equivalence margin ±337.2 U/L; difference 34.48 U/L (95% CI −47.66 to 116.62) 559 |
| Key regulator concerns | FDA: LDH nonspecificity (blinded committee excluded confounded values), post-randomization exclusions, crossover carryover 249250251. CHMP: stable patients may be insensitive to differences, accepted given PNH rarity 215216 | FDA: unplanned product switches during a Soliris shortage 435. CHMP: LDH insufficiently specific, Week 26 possibly too late, crossover strongly discouraged; breakthrough hemolysis imbalance and a divergent opinion 563564562566 |
Two points matter for future biosimilar programs. FDA's 0.77 to 1.29 AUEC bound was linked to hemoglobin stabilization, judging a difference of no more than 10% clinically unimportant and preserving at least 80% of the Soliris effect 246. CHMP accepted non-inferiority rather than equivalence for Bekemv because superiority in maintaining efficacy was implausible in stabilized patients 215.
Cross-cutting regulatory themes
- Transfusion avoidance needs protocol-defined triggers. Both agencies accepted transfusion avoidance as clinically meaningful in open-label trials only where prespecified transfusion criteria limited investigator discretion 411513642698.
- LDH is accepted as a hemolysis measure, but framing matters. FDA preferred LDH normalization or threshold-based control over percent change in active disease 412. LDH percent change was acceptable for maintenance in switch populations 409668. CHMP cautioned against LDH as the sole severity criterion 734.
- Hemoglobin endpoints dominate where extravascular hemolysis drives residual anemia. Hb change, sustained Hb response and Hb stabilization served as primary endpoints for pegcetacoplan, iptacopan and danicopan 261541589. LDH failed non-inferiority in APL2-302 without blocking approval 88334.
- Non-inferiority margins are re-derived conservatively. FDA consistently recalculated margins from the lower confidence bound of TRIUMPH effects rather than point estimates or registry data 395507512. CHMP raised similar points but did not pursue them where results were robust 661663.
- PROs remain supportive in open-label settings. FACIT-Fatigue was described as potentially biased or difficult to interpret in open-label trials and was excluded from crovalimab labeling 399413514546.
- Single-arm and external data are supportive, not pivotal. Single-arm studies (SHEPHERD, APPOINT-PNH, COMMODORE 3) supported randomized pivotal trials 472643691. FDA rejected an external-comparator switch design 520.