Rhizome

EMA Conditional Marketing Authorisations Based on Surrogate and Intermediate Endpoints: Precedents and Specific Obligations

Chetan Mishra
Chetan Mishra
Oct 16, 2026

Conditional marketing authorisation lets sponsors reach the EU market before comprehensive clinical data exist, often on response rates, biomarkers or other surrogate measures. For regulatory and clinical teams planning an EU strategy, it matters how the CHMP has judged these endpoints and what confirmatory commitments it attached. Those precedents shape trial design, the timing of confirmatory studies and the risk to the authorisation after approval.

The analysis below covers the legal basis for conditional marketing authorisation under Regulation (EC) No 726/2004 and how specific obligations work in Annex II.E. It then goes through EMA precedents in oncology, haematology, hepatology, haemostasis and HIV where approval rested on surrogate or intermediate endpoints. For each product it sets out the obligations imposed and what followed: conversion to a standard authorisation, or withdrawal of the product or an indication.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.

EMA conditional marketing authorisation on surrogate and intermediate endpoints: precedents and specific obligations

EMA has granted conditional marketing authorisations (CMAs) on surrogate or intermediate endpoints in two main settings. The first is oncology and haematology, where single-arm or uncontrolled trials supported approval on response rates. The second is hepatology, haemostasis and HIV, where approval rested on biochemical, histological, biomarker or virological endpoints. In each case the CHMP required confirmation through specific obligations set out in Annex II.E. The track record runs both ways. Several products converted to standard authorisations once confirmatory studies reported (Intelence, Blincyto, Pixuvri, Adcetris). Others lost their authorisation or an indication when confirmatory studies failed (Blenrep monotherapy, Ocaliva, Rubraca treatment indication). Blenrep was later authorised again for combination regimens under a new procedure.

This article sets out the legal basis, how the CHMP has described these endpoints, the specific obligations attached to each precedent, and what happened next.

Legal basis and how specific obligations work

Under Article 14-a of Regulation (EC) No 726/2004, a CMA may be granted before comprehensive clinical data are available. The medicine must treat, prevent or diagnose a seriously debilitating or life-threatening disease and meet an unmet medical need: either no satisfactory authorised method exists in the Union, or the medicine offers a major therapeutic advantage. The benefit of immediate availability must outweigh the risk that additional data are still needed 69. Under Regulation (EC) No 507/2006, the scope also covers orphan medicines and medicines for use in recognised public-health emergencies. The benefit-risk balance must also be positive, and the applicant must be likely to provide comprehensive data 70.

The mechanics that matter for sponsors:

  • Specific obligations are binding conditions. They are set out in the conditions of the authorisation, with deadlines where appropriate. They include completing ongoing studies or running new ones to confirm the favourable benefit-risk balance 71. EMA's post-authorisation procedural advice places them in Annex II.E of the Commission decision 166.
  • Annual review and renewal. The Agency reviews the specific obligations every year 744. Renewal depends on a reassessment of the benefit-risk balance, including compliance with the specific obligations, through the annual renewal procedure 167. The CMA is valid for one year and is renewable 72.
  • Labelling disclosure. The SmPC and package leaflet must state clearly that the authorisation is subject to specific obligations 745.
  • Conversion. Once the obligations are fulfilled, the Commission may grant a standard authorisation valid for five years, on the holder's application and after a favourable Agency opinion 72. The route only runs one way: an existing standard authorisation cannot later be converted into a CMA 168.

How the CHMP characterises surrogate and intermediate endpoints

EPAR language varies a great deal by therapeutic area. That matters when a sponsor frames its own endpoint justification.

Explicit "surrogate" or "intermediate" framing (non-oncology).

  • Ocaliva (obeticholic acid), primary biliary cholangitis (PBC): the CHMP described the biochemical changes as a surrogate for clinical efficacy rather than shown improvement in clinical outcomes. It said the link to liver outcomes remained uncertain 765766.
  • Iqirvo (elafibranor), PBC: the biochemical biomarkers were called surrogate parameters reasonably likely to translate into clinically relevant outcomes, with long-term benefit still to be confirmed 488489. The CHMP also noted that the effect was mainly on alkaline phosphatase (ALP), with minimal effect on bilirubin 445.
  • Lyvdelzi (seladelpar), PBC: the biochemical response was called a surrogate reasonably likely to translate into clinical benefit. Its relevance to liver-related outcomes was unknown 55455525. The CHMP noted that the evidence linking ALP and bilirubin reductions to outcomes came from PBC natural history and UDCA. It had not been shown generally for new treatments 446.
  • Rezdiffra (resmetirom), MASH: the liver-histology endpoints were called intermediate endpoints, not fully validated surrogates in the strict sense, though reasonably likely to predict liver outcomes 662663.
  • Kayshild (semaglutide), MASH: the histology endpoints were called intermediate and reasonably likely to predict long-term clinical outcomes 260.
  • Ondexxya (andexanet alfa): the CHMP did not regard reversal of anti-factor Xa activity as a validated indicator of clinical efficacy, because its correlation with haemostatic efficacy had not been established 728.

Implicit framing (oncology response endpoints). In single-arm oncology CMAs, the CHMP has usually not labelled objective response rate (ORR) or duration of response (DoR) as "surrogate". Instead it has treated clinical benefit as an assumption that needs comparative or time-to-event confirmation.

  • Blenrep: the original CMA rested on ORR and DoR in DREAMM-2, judged long enough to potentially translate into clinical benefit 533534. The trial had no reference arm, so effects on PFS and OS could not be isolated 535536.
  • Retsevmo: the single-arm approach was accepted because the ORR effect was outstanding and durable in a rare population. The CHMP noted that time-to-event outcomes were hard to interpret 683134.
  • Aucatzyl: overall remission rate was accepted as the primary endpoint when read with durability of response 281282.
  • Enhertu, HER2-mutant NSCLC: the CHMP was explicit here. It stated that response rate and DoR "are not surrogate endpoints for OS and PFS" in this setting, and therefore that the uncontrolled data were not comprehensive enough for full approval 353.

Minimal residual disease (MRD). An expert consultation cited in the Blincyto assessment found a strong patient-level association between MRD negativity and event-free and overall survival. It had not been validated as a treatment-effect surrogate, but it was considered useful for an accelerated benefit-risk decision where unmet need was high, subject to confirmation on clinical outcomes 444. The later Blincyto indication in MRD-positive ALL was granted as a standard Type II extension, not a CMA. The original CMA was for relapsed or refractory ALL 814817.

Precedents: endpoint basis and specific obligations

Hepatology (biochemical and histological endpoints)

ProductCMA dateEndpoint relied onSpecific obligations (Annex II.E)
Ocaliva (obeticholic acid), PBCDecember 2016 765Study 747-301 composite: ALP <1.67 x ULN, normal total bilirubin, ALP decrease of at least 15% 765768Study 747-302, randomised placebo-controlled clinical-outcomes study. Study 747-401, efficacy, safety and PK in moderate-to-severe hepatic impairment. Final reports later listed as due 2023 for both 769770
Iqirvo (elafibranor), PBC19 September 2024 481Cholestasis response (same ALP/bilirubin composite) in Study 319-1 488ELFIDENCE (CLIN-60190-454), phase III long-term clinical-outcomes study; due May 2030 491490
Lyvdelzi (seladelpar), PBCNot stated in the cited EPARWeek-52 biochemical response: 61.7% vs 20% placebo 552AFFIRM, phase III placebo-controlled outcomes study in compensated cirrhosis; due August 2030. ASSURE is a category 3 study, not an Annex II.E obligation 556557
Rezdiffra (resmetirom), MASH F2 to F318 August 2025 56852-week interim liver histology from MAESTRO-NASH (MASH resolution; fibrosis improvement) 661602Final results of MGL-3196-11 (MAESTRO-NASH), due 31 March 2029 666. MGL-3196-19 (MAESTRO-NASH OUTCOMES), due 31 March 2028 667
Kayshild (semaglutide), MASH F2 to F326 March 2026 240Week-72 interim histology from ESSENCE, a planned 240-week study 259261Final efficacy and safety results of NN9931-4553 (ESSENCE); due 31 December 2029 262

The MASH CMAs share one design. Accelerated approval rests on a prespecified interim histology readout, and the specific obligation is the final, outcomes-driven analysis of the same trial. Whether the histological effects translate into fewer events such as decompensation, transplantation or death had not been shown at authorisation 664665261.

Haemostasis and HIV

ProductCMA dateEndpoint relied onSpecific obligations
Ondexxya (andexanet alfa)26 April 2019 713Reversal of anti-FXa activity (healthy volunteers and ANNEXA-4), with haemostatic outcomes as co-primary 726727ANNEXA-4 (14-505) final CSR, due 30 June 2019 733. Study 19-514 Gen 1 vs Gen 2 comparative PK to confirm posology, due 30 September 2019 734. Study 18-513 (ANNEXA-I), randomised vs standard care in intracranial haemorrhage, originally due 30 June 2023 735 and later revised to 31 July 2024 737. Updated PK/PD model by Q3 2019 736
Intelence (etravirine), HIV-128 August 2008 519Week-24 virologic response (HIV-1 RNA <50 copies/mL) in DUET-1 and DUET-2 515Retrospective observational study TMC125IFD0000003 on activity and resistance with boosted PIs other than darunavir/ritonavir; due Q2 2013 517

The Ondexxya obligations stand out because they target the surrogate itself. They require data to examine the biomarker-haemostasis relationship and to clarify thrombotic risk against a concurrent control 733735729.

Oncology and haematology (response-based endpoints)

ProductCMA dateEndpoint relied onSpecific obligations
Adcetris (brentuximab vedotin), R/R HL and sALCL25 October 2012 492ORR (primary endpoint) and PFS in single-arm phase 2 studies 500501OS follow-up for SG035-0003/-004 (annual reports to 2015 and 2016) 504. PASS MA25101 (final 31 December 2018) 505. Single-arm sALCL study C25006 (final Q1 2016) 506. Single-arm HL study in ASCT-ineligible patients (final Q2 2016) 507
Pixuvri (pixantrone), aggressive B-cell NHL10 May 2012 299CR/CRu in PIX301, supported by PFS. OS not improved 645646PIX306, randomised pixantrone-rituximab vs gemcitabine-rituximab after CHOP-R; due date moved from 30 June 2015 to 31 December 2018 650649
Blincyto (blinatumomab), R/R Ph- B-precursor ALL23 November 2015 366CR/CRh* 42.9% in single-arm MT103-211; MRD response supportive 181TOWER (00103311), phase 3 vs standard-of-care chemotherapy; due Q1 2017 378379
Rubraca (rucaparib), BRCA-mutated ovarian cancer treatment24 May 2018 322ORR pooled from two single-arm phase 2 studies 323ARIEL4 (CO-338-043), phase 3 vs chemotherapy; due Q2 2023 325
Blenrep (belantamab mafodotin), 5L+ multiple myeloma25 August 2020 424ORR in single-arm DREAMM-2 533DREAMM-2 final results (April 2021, later February 2023) 537538. DREAMM-3 vs pomalidomide/dexamethasone, due July 2024 539540
Retsevmo (selpercatinib), RET-altered cancers11 February 2021 668ORR (IRC-assessed) and DoR in LIBRETTO-001 683LIBRETTO-001 final report 690. Phase 3 LIBRETTO-431 (NSCLC) 691 and LIBRETTO-531 (MTC) 692. Later variations added tumour-agnostic final data and LIBRETTO-121 695696
Enhertu (trastuzumab deruxtecan), multiple HER2 indications18 January 2021 for the initial breast indication; later indications added by variation 336ORR/DoR in U201 (breast) 351; U206 (HER2-mutant NSCLC) 353; DP-02 (HER2 IHC3+ solid tumours) 354DESTINY-Breast02 interim results, March 2022 358. DS-8201-A-U306 (gastric/GEJ) and DESTINY-Lung04, both Q4 2025 356357. DP-02 cohort A part 2, Q2 2027 359
Aucatzyl (obecabtagene autoleucel), R/R B-ALL17 July 2025 263Overall remission rate 76.6%, median duration of remission 14.06 months in single-arm FELIX 281FELIX final results, due 30 June 2029 286. AUTO1-LT2 registry-based non-interventional efficacy and safety study, due 31 July 2030 288

Other response-based CMAs follow the same pattern. Anktiva relied on a six-month complete response rate, with obligations to complete QUILT-3.032 (including five-year follow-up) and run the randomised QUILT-2.005 study 137138139. Caprelsa's obligation was an observational study (D4200C00104) to evaluate benefit-risk by RET mutation status 130132.

Typology of specific obligations

Across these precedents, Annex II.E obligations fall into a small number of types:

  1. Randomised comparative confirmation against standard of care or an active comparator: TOWER 378, ARIEL4 325, DREAMM-3 539, PIX306 649, LIBRETTO-431/531 691692, DESTINY-Lung04 357, ANNEXA-I 735.
  2. Clinical-outcomes trials to validate a biomarker or histology effect: 747-302 769, ELFIDENCE 491, AFFIRM 556, MAESTRO-NASH OUTCOMES 667.
  3. Final or long-term analysis of the pivotal study itself: MAESTRO-NASH 666, ESSENCE 262, FELIX 286, LIBRETTO-001 690, DP-02 359, and Adcetris OS follow-up 504.
  4. Studies aimed at the surrogate-outcome relationship and dose: Ondexxya's biomarker-correlation, comparative PK and PK/PD model obligations 733734736.
  5. Population and real-world gaps: special populations (Ocaliva 747-401, hepatic impairment 769), off-label regimen coverage (Intelence 517), registries (Aucatzyl AUTO1-LT2 288), and further single-arm studies in populations not covered at approval (Adcetris 506507).

Due dates often move. Pixuvri's PIX306 deadline moved from 2015 to 2018 650649. Blenrep's DREAMM-2 obligation moved from April 2021 to February 2023 537538. Ondexxya's ANNEXA-I moved from June 2023 to July 2024 735737. Retsevmo's LIBRETTO-431 moved from October 2023 to December 2024 691693.

What happened next

Converted to standard authorisation after obligations were fulfilled

  • Intelence: renewed as conditional each year from 2009 to 2013 456460. The final retrospective cohort (1,115 people) found no significant difference between etravirine with darunavir/ritonavir and with other PIs. The CHMP recommended an authorisation no longer subject to specific obligations on 19 September 2013, about five years after the CMA 96.
  • Blincyto: TOWER showed longer overall survival than chemotherapy (7.7 vs 4.0 months) and higher MRD negativity (23.6% vs 9.0%), fulfilling the obligation 194. The authorisation switched to standard on 18 June 2018 195196189.
  • Pixuvri: PIX306 was submitted in November 2018 and was judged to corroborate benefit, including after prior rituximab 6162305. On 28 March 2019 the CHMP recommended removing the specific obligations 306. The product's listed status is now "Expired", meaning the authorisation later lapsed after conversion and is no longer in force 290.
  • Adcetris: renewed as conditional for nearly a decade 228235. The final obligation (C25006) showed ORR above 60% with durable responses 236237. On 24 March 2022 the CHMP concluded that all specific obligations were fulfilled 238239.

Converted, but only after the indication was restricted

  • Rubraca: the ARIEL4 overall-survival analysis raised concern about a potential detrimental effect compared with chemotherapy 474. The CHMP recommended a change on 21 July 2022 and the treatment indication was removed 474475476. Rubraca switched to a standard authorisation on 9 November 2022 and remained authorised for maintenance treatment 468477. Submitting the confirmatory data fulfilled the procedural obligation. It did not confirm the original surrogate-based benefit.

Not renewed or revoked after confirmation failed

  • Blenrep (monotherapy): the CHMP considered the DREAMM-2 obligation fulfilled. DREAMM-3 then failed to show PFS or OS benefit, so the DREAMM-3 obligation could not be considered fulfilled 427428429. The Commission decided on 23 February 2024 not to renew the CMA 778. Blenrep was later authorised again on 23 July 2025, under a new procedure (EMEA/H/C/006511), for combination regimens 778779.
  • Ocaliva: in 2020 the independent monitoring committee judged 747-302 unlikely to show efficacy. Both obligation studies were terminated early 771. The primary clinical composite showed no difference (HR 1.01, 95% CI 0.68 to 1.51) 772. The CHMP found conversion to a full authorisation not approvable 773, and the product is listed as revoked 391. This is the clearest EU example of a biochemical surrogate that did not hold up against clinical outcomes 448449.
  • Lartruvo: strictly, this was not a surrogate case. Its CMA rested on PFS and an OS difference (26.5 vs 14.7 months) in a small randomised phase 1b/2 study 805806. The confirmatory ANNOUNCE study failed its survival objective. An Article 20 review began on 25 January 2019 and the CHMP recommended revocation 811812. It shows that a randomised but exploratory basis carries a similar risk.
  • Translarna: a related case. Its 2014 CMA relied on a post hoc six-minute walk distance signal. Phase 3 studies 020 and 041 did not replicate it, and the CHMP recommended non-renewal 405406407409.

Still conditional at the most recent published renewal

Ondexxya has been renewed as conditional every year from 2020 to 2025. Its 2025 renewal still lists the specific obligations 626630. Retsevmo was renewed as conditional through a January 2025 Commission decision 709710. An April 2025 assessment notes outstanding Enhertu obligations for the gastric and NSCLC indications 564565. Rezdiffra had a one-year renewal opinion on 23 April 2026 598599. Iqirvo, Lyvdelzi, Kayshild and Aucatzyl have long-dated obligations (2029 to 2030) with no confirmatory readout reported in their published EPARs as of October 2026 491556262286288.

Practical implications for sponsors

  • Justify the endpoint in the CHMP's own terms. In hepatology and haemostasis, the CHMP has explicitly said whether an endpoint is a surrogate, an intermediate endpoint or not validated 554662728. In oncology, the debate is about whether an uncontrolled response rate can stand in for time-to-event benefit 353535. "Reasonably likely to predict clinical benefit" can support a CMA, but it is not validation 444.
  • Have the confirmatory study under way at submission. Most successful conversions relied on a randomised study that was already running at the time of CMA (TOWER, PIX306) 378649. In MASH, the obligation is the outcomes phase of the same pivotal trial 666262.
  • Expect obligations to be realistic about feasibility. For Adcetris, the CHMP accepted further single-arm studies because a randomised HL trial would have been difficult and a randomised second-line sALCL trial was not feasible 502503.
  • Plan for an unfavourable result. A failed confirmatory study has led to non-renewal (Blenrep) 429, revocation (Ocaliva, Lartruvo) 391812, or loss of the surrogate-based indication before conversion (Rubraca) 474468. Under Article 14-a, annual renewal is the point at which these consequences take effect 72167.
  • Budget for a long conditional period. In the precedents above, the time from CMA to removal of specific obligations ranged from about two and a half years (Blincyto, 2015 to 2018) to nearly a decade (Adcetris, 2012 to 2022) 366189492238.
Rhizome did this research. Let it help you with your most critical decisions by creating a free account.