Rhizome

Antibody Titers, Immunobridging and Correlates of Protection in FDA Approvals

Chetan Mishra
Chetan Mishra
Nov 1, 2026

For vaccines and other immune-based products, efficacy trials with clinical disease endpoints are often infeasible, unethical, or impractically large, particularly once an effective product exists or when disease incidence is low. Regulatory and clinical teams therefore need to know when FDA will accept antibody titers or other immune-response measures in their place, and what level of evidence links those measures to protection.

The analysis below reviews FDA approvals that relied on immune-response endpoints, sorted by the evidentiary framework used: established immune markers, immunobridging, accelerated approval, and the Animal Rule. It also compares how CBER and CDER justified those endpoints in their review documents and labeling.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.

Antibody titers, immunobridging and correlates of protection in FDA approvals

FDA has approved many products on the basis of immune-response endpoints rather than clinical disease outcomes. Almost all of them are vaccines reviewed by CBER. The approvals fall into four distinct evidentiary categories, and FDA's justification differs for each:

  1. Established immune markers that support traditional approval, such as anti-HBs ≥10 mIU/mL for hepatitis B vaccines and opsonophagocytic activity (OPA) for invasive pneumococcal disease.
  2. Immunobridging, where effectiveness is inferred from noninferior immune responses compared with a population or product in which clinical efficacy was already shown. FDA has used this for COVID-19 vaccines, RSV vaccines, pneumococcal conjugate vaccines and smallpox vaccines.
  3. Immune responses "reasonably likely to predict clinical benefit", which support accelerated approval with a required confirmatory study. Examples include influenza HI titers, chikungunya neutralizing titers and OPA for pneumococcal pneumonia.
  4. Animal Rule immunobridging, where human antibody levels are linked to survival in animal challenge models. The anthrax vaccines are the main examples.

The CDER record is much thinner. CDER-reviewed anthrax antitoxin monoclonal antibodies were approved under the Animal Rule using cross-species drug exposure bridging. That is not a vaccine-style immune-response endpoint. In the CDER labels and reviews examined, serum neutralizing titers or immunobridging were not identified as a basis for any approval.

Regulatory framework: validated surrogates vs. "reasonably likely" surrogates

FDA guidance separates two levels of certainty. A validated surrogate endpoint can support ordinary (traditional) approval. A surrogate that is reasonably likely to predict clinical benefit is a lower level of certainty and supports accelerated approval only, with studies required to verify clinical benefit 233236237. For vaccines, FDA describes clinical disease-endpoint efficacy trials as the most direct way to show effectiveness. It also notes that identifying an immune correlate of protection in such a trial can help interpret later immunogenicity-bridging studies 234235.

FDA treats correlates as specific to the product and the evidence. The COVID-19 vaccine guidance says a potential surrogate depends on the vaccine's characteristics, and that a marker established for one vaccine platform cannot simply be assumed to apply to another 239. The same guidance says understanding of immune responses that predict COVID-19 protection was limited and evolving. New vaccine programs were therefore told to pursue traditional approval based on direct efficacy evidence 411. Accelerated approval based on an immune-response surrogate "may" be considered when there is enough evidence that the surrogate is reasonably likely to predict benefit. FDA said such a marker should ideally come from human efficacy studies of clinical disease 412.

For influenza, FDA guidance places HI antibody responses in the "reasonably likely" category. They may be acceptable for accelerated approval even though prospective effectiveness studies had not identified a specific HI titer associated with protection, and confirmatory postmarketing effectiveness studies are required 238. For pandemic influenza vaccines, FDA suggests these success criteria for adults under 65 and for children: a lower bound of the two-sided 95% CI of at least 40% for seroconversion and at least 70% for an HI titer ≥1:40 415. Seroconversion is defined as a rise from <1:10 to ≥1:40, or at least a fourfold rise when the baseline titer is ≥1:10 418. FDA calls these current recommended targets and says they are not the only acceptable ones, because understanding of immune responses to pandemic strains is still evolving 416.

Category 1: established immune markers supporting traditional approval

Product / classImmune endpointHow FDA justified it
HEPLISAV-B (hepatitis B, adjuvanted)Seroprotection rate, anti-HBs ≥10 mIU/mL; noninferiority to Engerix-B with a 95% CI lower bound >−10% 261262263FDA states that anti-HBs ≥10 mIU/mL is recognized as protective. Immunocompetent vaccinees who reached that level had virtually complete protection against acute and chronic hepatitis, even if antibody later fell below it 265266
PREHEVBRIO (hepatitis B)Anti-HBs ≥10 mIU/mL four weeks after dose 3; noninferiority to Engerix-B with a lower bound >−5% 268269FDA called ≥10 mIU/mL the established correlate of protection against HBV infection, and concluded that the two pivotal trials supported licensure 270267
HIBERIX (Hib)Anti-PRP ≥0.15 mcg/mL (minimal protective level); ≥1.0 mcg/mL predicts protection for at least one year 80Labeling traces these levels to passive-antibody studies and an efficacy study of unconjugated Hib polysaccharide vaccine, and notes they have been used to evaluate Hib conjugate vaccines 80
PRIORIX (MMR)ELISA thresholds: measles 200 mIU/mL, mumps 10 ELU/mL, rubella 10 IU/mL, compared with M-M-R II 87The measured IgG correlates with neutralizing antibodies associated with protection. First-dose responses were noninferior to M-M-R II 8889
IMOVAX RABIESRabies virus neutralizing antibody ≥0.5 IU/mL 90The reviewer called 0.5 IU/mL a widely accepted, conservative indicator of protection, citing animal protection at lower levels and historical human experience 91
Meningococcal vaccines (MenQuadfi, Bexsero, Trumenba, Penbraya, Penmenvy)Serogroup- or strain-specific hSBA seroresponse and composite responses 372376378379380381382For Bexsero, FDA said protection is mainly mediated by complement-dependent killing and that direct effectiveness trials are impractical at low U.S. incidence. It also noted that strain diversity limits how broadly an hSBA result can be interpreted 375. For MenQuadfi, serogroup-specific efficacy was inferred from hSBA seroresponse 371
VAXCHORA (cholera)Day 11 vibriocidal seroconversion (≥4-fold rise), used to bridge from adults 18 to 45 to older adults 81Seroconversion was associated with lower diarrheal volume after challenge. Only 2 of 62 vaccinees who seroconverted developed moderate or severe cholera after challenge 81

Pneumococcal conjugate vaccines: OPA and IgG as bridging markers

FDA accepted OPA as an established immunologic parameter for inferring protection against invasive pneumococcal disease (IPD) through comparison with licensed vaccines. For PREVNAR 20 in adults, this supported traditional approval for IPD caused by all 20 serotypes. The 13 shared serotypes were compared with PCV13 and the seven new serotypes with PPSV23 610611. Adults 18 to 49 and 50 to 59 were then bridged to PREVNAR 20 recipients aged 60 to 64. For each serotype, the lower bound of the 95% CI for the OPA GMT ratio had to exceed 0.5 150151. For VAXNEUVANCE, the statistical review describes licensure as inferred effectiveness through immunobridging to PREVNAR 13. It cites PREVNAR 13's later confirmation of efficacy in the CAPiTA study and the infeasibility of new efficacy studies when uptake of approved vaccines is high 153.

In infants, FDA used the percentage reaching a serotype-specific IgG concentration (classically ≥0.35 µg/mL) after dose 3 as the endpoint. FDA was explicit that this is a bridging threshold, not an established protective level for every serotype. The PCV15 review says it followed a WHO recommendation to bridge to PCV7 efficacy, and the Prevnar 13 memo states that no protective IgG level had been established for any serotype 499500. The noninferiority margin was a −10 percentage-point lower bound 501504505. When serotypes missed the criterion, FDA looked at the totality of the immune data rather than treating the miss as definitive:

  • Prevnar 13: serotypes 6B, 9V and 3 missed, and FDA also considered functional OPA responses 502503.
  • PREVNAR 20: six serotypes missed, and IgG GMC and OPA data supported effectiveness for them 507.

Category 2: immunobridging to demonstrated efficacy

COVID-19 vaccines

FDA presented immunobridging to VRBPAC as a comparison with a regimen whose clinical efficacy had already been shown. It was not presented as proof that a particular titer guarantees protection. FDA stated that neutralizing antibodies were clinically relevant but that no specific titer had been established to predict protection 337338. For pediatric programs, FDA proposed noninferiority margins of −10% for the seroresponse rate (SRR) difference and 1.5-fold for the GMT ratio. FDA cautioned that a lower pediatric dose might require better understanding of the relationship between titer and protection, and encouraged direct efficacy evaluation where feasible 339340.

  • SPIKEVAX, adolescents 12 to 17: Day 57 neutralizing ID50 GMT and SRR were compared with adults 18 to 25 from the pivotal efficacy trial. Success required a GMT ratio lower bound >0.67 and an SRR difference lower bound >−10 percentage points, and both were met 137141. Adolescent COVID-19 incidence was a secondary, descriptive objective 142.
  • COMIRNATY, adolescents 12 to 15: Noninferiority of the neutralizing GMT ratio compared with 16- to 25-year-olds required a lower bound >0.67 144145. The reviewer identified immunobridging, not the exploratory efficacy objective, as the basis for inferring effectiveness 146.
  • NUVAXOVID, adolescents and boosters: The adolescent GMT ratio needed a lower bound >0.67 and a point estimate >0.82, and the seroconversion-rate difference needed a lower bound >−10 percentage points. All three were met 149. FDA noted the adolescent study was not powered to establish efficacy 148. Booster effectiveness was inferred from noninferior responses after the booster compared with after the primary series 147.
  • Booster and pediatric EUAs: FDA's briefing documents show that it applied these criteria consistently. The Moderna 50-µg booster met the GMT ratio criterion but did not meet the prespecified SRR criterion 342343344345. FDA characterized the Janssen booster analysis as a post-hoc analysis of 17 participants, not prespecified hypothesis testing 346. For BNT162b2 in children 5 to 11, and in children 6 months to 4 years, effectiveness was inferred by bridging to 16- to 25-year-olds 347348349.

RSV vaccines in adults under 60

RSV vaccine indications for adults at increased risk of lower respiratory tract disease were extended to younger ages through supplements: AREXVY to ages 50 to 59 and 18 to 49, and ABRYSVO and MRESVIA to ages 18 to 59 431432433434435436437. For these extensions, the bridge was to older adults in whom efficacy had been shown:

  • AREXVY: At-risk adults 50 to 59 were compared with recipients aged 60 and older on RSV-A and RSV-B neutralizing GMTs and SRRs. Noninferiority required an upper CI bound ≤1.50 for the GMT ratio (60+ divided by 50 to 59) and ≤10 percentage points for the SRR difference. Both subtypes met these criteria 665666668669670.
  • ABRYSVO: At-risk adults 18 to 59 (Study 4) were compared with adults 60 and older (Study 3). Adjusted GMT ratios were 1.57 for RSV A and 1.52 for RSV B, and SRR differences were 5.1 and 8.3 percentage points. All lower bounds cleared the 0.667 and −10 point margins 672674676677.
  • MRESVIA: The available documents describe the planned P303 immunobridging design but do not give the success criteria or results 702.

Smallpox and mpox vaccines

The JYNNEOS approval shows FDA requiring immunobridging plus animal efficacy evidence when there is no correlate. The endpoint was noninferiority of vaccinia-neutralizing PRNT GMT to ACAM2000, with a 0.5 margin 295. FDA considered animal protection data critical because the two vaccines differ and no neutralizing-antibody level predictive of smallpox protection had been established 295297. ACAM2000's original approval used noninferiority to Dryvax for vaccine take and Day 30 neutralizing GMT 300301302. Its later mpox indication rested on macaque challenge protection plus human observational data, because direct human efficacy testing was infeasible 298303304.

Category 3: accelerated approval on immune responses reasonably likely to predict benefit

ProductPopulationSurrogateConfirmatory requirement
FLUCELVAX / FLUCELVAX QUADRIVALENTAges 4 to <18 3741HI GMTs and % with HI ≥1:40 3842Clinical-endpoint efficacy study V130_12 4043
FLUAD QUADRIVALENTAdults ≥65 26HI titers 2728Absolute-efficacy trial V118_24 29
AUDENZPersons ≥6 months (accelerated approval) 30HI ≥1:40, called "the best available surrogate" 31Not specified
MFLUSIVA (mRNA influenza)Adults ≥65 631Day 29 HAI GMT ratio and seroconversion, superior to Fluzone High-Dose Quadrivalent 63233Phase 4 relative-effectiveness study against high-dose vaccine (mRNA-1010-P910) 36633
PREVNAR 20 (pneumonia, 7 new serotypes)Adults 607OPA titers 607Test-negative study B7471015 in adults ≥65 609
CAPVAXIVE (pneumonia)Adults ≥18 77OPA GMT 78Confirmatory effectiveness study 78
IXCHIQ (chikungunya, live)Adults ≥18 at increased exposure risk 45Neutralizing titer ≥150 at Day 28 46Postmarketing confirmatory studies 48
VIMKUNYA (chikungunya, recombinant)Ages ≥12 49Neutralizing NT80 titer ≥100 at Day 22 49Event-driven placebo-controlled efficacy study EBSI-CV-317-007 659660661

The reviews give several types of justification:

  • Influenza: shortage and seriousness. In an early HI-based review (AFLURIA), FDA stated that HI ≥1:40 was not an established immunologic correlate of protection 73. It nonetheless treated the co-primary HI endpoints as reasonably likely to predict benefit, citing the risk of serious influenza illness during an anticipated vaccine shortage, with postmarketing clinical-endpoint studies required 2474. For FLUCELVAX in ages 4 to <9, traditional approval was not supported because noninferiority to Fluvirin failed for A/H3N2. The observed response was still accepted as reasonably likely to predict benefit 38.
  • Influenza: correlate-of-risk analysis. For MFLUSIVA, adults 50 to 64 received traditional approval based on a relative vaccine efficacy of 26.6% (95% CI 16.7 to 35.4) compared with a standard-dose vaccine 629630. Adults 65 and older received accelerated approval. The P304 efficacy data were only supportive in that group because the standard-dose comparator was not preferentially recommended for older adults 632. FDA cited the biological plausibility of HAI and a prespecified correlate-of-risk analysis that linked Day 29 HAI titers to illness for A/H1N1 and A/H3N2. The analysis was inconclusive for B/Victoria because of few cases 35.
  • Pneumococcal pneumonia: feasibility and ethics. FDA said immunogenicity alone was insufficient for a noninvasive-disease indication because antibody levels had not been shown to predict prevention of pneumonia. It also found that an active-controlled efficacy trial was impracticable and that a U.S. placebo-controlled trial would be unethical 607608. For CAPVAXIVE, FDA noted that OPA measures antibody-mediated bacterial killing and reflects a plausible mechanism of protection, while no accepted protective threshold exists in adults 78.
  • Chikungunya: thresholds from nonhuman primates. Both chikungunya thresholds were derived from passive transfer of human immune serum in nonhuman primate challenge models, with prevention of viremia as the outcome 7549. FDA explicitly recorded the limits of this evidence. Prevention of disease had not been shown in the model, and other nonclinical studies found protection against viremia without protection in joints 7547657658. In the VIMKUNYA phase 3 studies, 97.8% of vaccinees aged 12 to <65 and 87.3% of those ≥65 reached the threshold, compared with about 1% of placebo recipients. Both studies met a ≥70% lower-bound criterion 654655656.

Risk with surrogate-based licensure: IXCHIQ

IXCHIQ shows what can happen when a surrogate-based approval is followed by unresolved safety signals. FDA's suspension memorandum records several steps:

  • Approval: Accelerated approval on November 9, 2023, on a surrogate endpoint. No confirmatory study had yet demonstrated vaccine effect 592.
  • Pause: FDA and CDC recommended pausing use in people 60 and older in May 2025 579580.
  • Label change: Labeling was revised on August 6, 2025, to narrow the indication and add serious chikungunya-like illness warnings 581582.
  • New findings: By August 15, 2025, there were 32 serious adverse-event cases, including 21 hospitalizations and three deaths 584585.
  • Suspension: The license was suspended effective August 22, 2025 587588. FDA cited the absence of completed confirmatory trials and of directly demonstrated effectiveness 583593. CBER said it would propose withdrawal of the accelerated approval unless Valneva timely requested that the matter be held in abeyance 591.

Category 4: Animal Rule immunobridging

FDA's Animal Rule guidance asks sponsors to choose immune markers and to characterize the animal immune response associated with disease prevention. Those data then guide a human dose and schedule that produce analogous responses 312. The guidance warns that antibody levels alone are not necessarily a sufficient correlate, and that some pathogens may need cellular-response markers as well 313314.

  • BioThrax (anthrax PEP): The endpoint was the proportion with toxin-neutralizing antibody (TNA) NF50 ≥0.56 at Day 63. That threshold corresponded to a 70% probability of survival in rabbits 110111. FDA considered TNA a functional measure and concluded that animal thresholds predicting 70% survival gave a reasonable basis for predicting human benefit 112.
  • CYFENDUS (AV7909): There were two co-primary endpoints: NF50 ≥0.56 at Day 64, and noninferiority to BioThrax on the proportion reaching NF50 ≥0.29. The ≥0.29 threshold was accepted based on at least 70% protection in nonhuman primates 11511686. FDA noted that the TNA assay is species-independent, so it allows direct comparison between animals and humans 117. Both criteria were met 118.

CDER: exposure bridging, not immune-response endpoints

CDER's closest analogues are the anthrax antitoxin monoclonal antibodies approved under the Animal Rule. Their efficacy was shown on survival in rabbits and cynomolgus macaques. The human dose was justified by cross-species pharmacokinetic and exposure–response comparisons:

  • Raxibacumab: At 40 mg/kg, human serum levels were comparable to concentrations associated with survival in animals 179180181.
  • ANTHIM (obiltoxaximab): At 16 mg/kg, humans were predicted to have similar peak concentrations and twice the overall exposure seen in infected animals at a fully effective dose 184185.

These programs used the concentration of the administered antibody, not a host immune response 178.

Other CDER-relevant findings point the same way:

  • Beyfortus (nirsevimab): The review mentions serum neutralizing antibodies in a cotton-rat rechallenge study, but cautions that it is unclear whether the finding can be extrapolated to humans. It does not present titers as an approval endpoint 306.
  • Evusheld (COVID-19 pre-exposure prophylaxis, EUA): FDA's December 2021 announcement based the authorization on the placebo-controlled PROVENT trial, which showed a 77% lower risk of COVID-19. The announcement does not cite neutralizing titers 487488.
  • Rabies mAb cocktails (draft guidance): FDA warns that rabies neutralizing antibody levels do not measure breadth of activity. It says the efficacy assumption applied to standardized human rabies immune globulin cannot be extrapolated to monoclonal antibody cocktails 208.

Practical takeaways for sponsors

  • Choose the category up front. An established correlate (anti-HBs, hSBA, OPA for IPD) supports traditional approval. Immunobridging needs a reference population or product with demonstrated efficacy. An unvalidated marker leads to accelerated approval with a confirmatory study.
  • Expect standard margins. The recurring immunobridging criteria are a GMT ratio lower bound of >0.67 (or an upper bound ≤1.5 when the ratio is inverted) and an SRR or seroconversion difference lower bound >−10 percentage points 141339668674. Pneumococcal OPA GMT bridges have used a lower bound of >0.5 151.
  • Missing one co-primary endpoint matters. FDA reported the Moderna booster SRR miss explicitly 344. For PCVs, FDA looked to supportive immune data before accepting effectiveness for serotypes that missed 503507.
  • Thresholds derived from animals carry visible uncertainty. FDA documents the gap between the animal endpoint (viremia, survival) and human disease, and it ties approval to confirmatory studies or Animal Rule conditions 75658313.
  • Accelerated approval on an immune marker needs a confirmatory study that can actually be completed. The IXCHIQ suspension shows the regulatory exposure when confirmatory trials are still incomplete and safety signals emerge 583591.
Rhizome did this research. Let it help you with your most critical decisions by creating a free account.