Rhizome

FDA Precedents for Removing or Narrowing Boxed Warnings and the Supporting Postmarketing Evidence

Chetan Mishra
Chetan Mishra
Sep 27, 2026

A boxed warning is the most prominent safety signal in US prescribing information. It shapes how prescribers weigh a product, how payers and formulary committees view it, and how competitors position against it. For sponsors whose product carries a box, knowing how FDA has handled past requests to remove or narrow one helps them plan the postmarketing studies, safety analyses, and labeling supplements that a credible request needs.

The analysis below reviews documented cases where FDA removed or narrowed a boxed warning. It sets out the labeling standard a boxed warning must meet, groups the precedents by the kind of evidence FDA relied on, and describes where the underlying risk information went in the revised label.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.

FDA precedents for removing or narrowing a boxed warning, and the evidence behind them

FDA has removed or narrowed boxed warnings many times. The evidence behind these changes falls into distinct types. A few removals rest on large randomized postmarketing requirement (PMR) safety trials built to answer the question that prompted the box. Varenicline and the ICS/LABA class are the clearest examples. Others rest on long-term pharmacoepidemiology programs (teriparatide), on new outcome-trial data that changed the size of the risk (canagliflozin, rosiglitazone), or on FDA's own class-wide labeling reassessments that found the box was not needed to manage a well-understood risk (bevacizumab, cabozantinib, ipilimumab). In the removal cases, the risk itself stayed in the label, usually moved to Warnings and Precautions. FDA was not saying the risk had gone away. Narrowing cases are different: some risks stayed in a shorter box.

The regulatory standard a removal has to meet

FDA labeling guidance says a boxed warning is ordinarily used when one of the following applies 195:

  • an adverse reaction is so serious relative to benefit (fatal, life-threatening or permanently disabling) that prescribers must weigh it;
  • a serious reaction can be prevented or reduced by appropriate use (patient selection, monitoring, avoiding certain concomitant therapy);
  • the drug was approved with restrictions to assure safe use.

The guidance also allows a box for a risk-benefit issue that is unique within a drug class 194. The same guidance does not set separate criteria for removing a box. It does say that application holders must keep labeling accurate and must change it when new information makes it inaccurate or misleading 210. A substantive boxed warning change must be listed under Recent Major Changes in Highlights for 12 months 196. In practice, the precedents below show that removal arguments work best when they speak directly to these criteria. The strongest ones show that the risk is smaller than first thought, that it is manageable without a box, or that the box is inconsistent with how FDA labels comparable products.

Category 1: Removal supported by dedicated postmarketing randomized trials

Chantix (varenicline): neuropsychiatric events, removed December 2016

This is the best-documented precedent. FDA removed the boxed warning for serious neuropsychiatric adverse events on December 16, 2016. The risk stayed in Warnings and Precautions, which was revised to include frequencies from the postmarketing safety trial 6628.

The supporting evidence was PMR study A3051123 (EAGLES). This was a randomized, double-blind, active- and placebo-controlled trial of varenicline 1 mg twice daily, bupropion 150 mg twice daily, nicotine replacement therapy (NRT) and placebo. Patients received 12 weeks of treatment followed by 12 weeks off treatment 44. The trial enrolled 8,144 patients at 140 centers in 16 countries. It was deliberately split into a non-psychiatric cohort and a psychiatric-history cohort of 4,074 patients with stable, confirmed DSM-IV diagnoses 44.

  • Primary endpoint: a composite of clinically significant neuropsychiatric events during treatment plus 30 days 282285. The trial was designed to estimate risk. It was not designed to exclude a prespecified margin or to assess rare outcomes such as suicidality 285177.
  • Non-psychiatric cohort: varenicline was not associated with an increased incidence of the composite endpoint 282279. Serious neuropsychiatric events occurred in 0.1% on varenicline versus 0.4% on placebo 286.
  • Psychiatric cohort: event rates were higher in every arm. The risk difference for varenicline versus placebo was 1.59% (95% CI -0.42% to 3.59%) in one FDA summary and 2.7% (-0.05% to 5.4%) in the labeling summary 282286.
  • Sensitivity analysis: an FDA analysis that excluded patients previously exposed to study drugs did not change the primary result 2656.

At the September 14, 2016 joint advisory committee meeting, members voted 10 to remove the box, 4 to modify it and 5 to retain it 7228. The committee concluded that observational studies added nothing beyond the randomized trial. It also stressed that psychiatric history was associated with greater risk, which should be communicated in labeling 56. Earlier pooled analyses of Phase II to IV trials had found no increased risk, but FDA noted that those trials were not designed to collect or adjudicate these events 26. That limitation is why a dedicated trial was needed.

EAGLES also included a Zyban (bupropion) arm 44. The Zyban labeling from the supplement decided June 1, 2016 still carried a boxed warning for serious neuropsychiatric reactions in patients taking bupropion for smoking cessation 267. FDA removed that part of the box on May 4, 2017 (NDA 020711/S-047, after EAGLES), and released the smoking-cessation REMS the same day; the antidepressant-class boxed warning on suicidal thoughts and behaviors remains (FDA approval letter, May 4, 2017). Earlier (2013) bupropion labels had cross-referenced the smoking-cessation neuropsychiatric risk to the Boxed Warning 257. The retrieved record does not fully document the decision rationale for bupropion on its own.

ICS/LABA combinations: asthma-related death, class-wide removal December 2017

On December 20, 2017, FDA removed the asthma-related death boxed warning from inhaled corticosteroid/long-acting beta-agonist (ICS/LABA) combination products, including Advair Diskus and Symbicort, as a class labeling change 4247.

The box originally came from the SMART trial, which studied salmeterol added to usual therapy without requiring an ICS. That trial found 13 asthma-related deaths in 13,176 patients on salmeterol versus 3 in 13,179 on placebo (relative risk 4.37; 95% CI 1.25 to 15.34) 301316. FDA regarded this as a class effect of LABA monotherapy 301.

After advisory committee discussions in 2008 and 2010, FDA required a harmonized PMR program. The trials were similarly designed and shared adjudication, steering and data monitoring committees so that rare events could be pooled 312306. Four trials were completed. The fifth (Foradil) was terminated after that product left the U.S. market 45.

  • Design: 26-week, randomized, double-blind noninferiority trials of ICS/LABA versus ICS alone. Three enrolled adults and adolescents and one enrolled children aged 4 to 11. The primary endpoint was a composite of asthma-related hospitalization, intubation or death 302301.
  • Noninferiority margins: 2.0 for adults and adolescents, 2.7 for children. Every trial met its noninferiority objective 302274.
  • FDA meta-analysis: hazard ratio 1.10 (95% CI 0.85 to 1.44) in adults and adolescents, based on 17,537 ICS/LABA and 17,552 ICS patients, and 1.29 (0.73 to 2.27) in children 305301.
  • Event counts in adults and adolescents: 116 composite events on ICS/LABA versus 105 on ICS, including 2 versus 0 deaths 301. The pediatric trial had no asthma-related deaths or intubations 301.

FDA's epidemiology and pulmonary divisions concluded that the four trials and the meta-analysis did not support keeping the box 45310. Warnings and Precautions was revised to keep and emphasize the asthma-related death risk of LABA monotherapy without an ICS 298. FDA also acknowledged that the trials could not rule out every level of risk and deferred conclusions on race and sex subgroups 302297.

Category 2: Removal supported by long-term pharmacoepidemiology

Forteo (teriparatide): osteosarcoma, removed November 2020

FDA removed the osteosarcoma boxed warning on November 16, 2020 229356. The evidence was a required five-part postmarketing surveillance program 351356:

StudyDesignKey finding
U.S. case series13-year cancer-registry surveillance with 1,173 patient or proxy interviewsNo safety concern identified 346238
Nordic case series10-year surveillance in five Nordic countries, 112 osteosarcoma records reviewedNo safety concern identified 352238
U.S. Forteo Patient RegistryProspective, linked annually to 42 cancer registries; 75,247 users, about 361,763 person-yearsNo incident osteosarcoma 346349
Medicare Part D cohort153,316 users versus 613,247 matched comparatorsRisk balanced between users and comparators 347348
IQVIA claims cohort29 state cancer registries; 335,192 users versus 637,388 osteoporosis comparatorsRisk balanced between users and comparators 346348

FDA judged the registry underpowered against its 1.7 million person-year target. It still concluded that the registry results did not suggest a risk 349. The multidisciplinary review found no evidence of increased osteosarcoma risk with up to two years of treatment 348349. FDA's Medical Policy and Program Review Council had agreed in April 2019 that the box was no longer necessary 229.

The removal came with related changes. An osteosarcoma precaution was kept for patients at higher baseline risk (open epiphyses, Paget's disease, prior skeletal radiation) 361. The lifetime two-year limit was relaxed so that longer use "should only be considered" in patients who remain at high fracture risk 357361. This is the main precedent for removing a box that was based on a nonclinical signal, using a mix of case series, a registry and claims-based cohort studies.

Category 3: Removal or narrowing after new outcome-trial data

Invokana and Invokamet (canagliflozin): lower-limb amputation, removed August 2020

FDA approved removal of the amputation boxed warning in August 2020 237332. The original box rested on CANVAS (hazard ratio 2.12; 95% CI 1.34 to 3.38) and CANVAS-R (hazard ratio 1.80; 95% CI 1.10 to 2.93) 318330.

CREDENCE studied a higher-risk diabetic kidney disease population. It showed a much smaller difference: 3.2% versus 2.9% (12.3 versus 11.2 per 1,000 patient-years), with an on-study hazard ratio of 1.1 (95% CI 0.8 to 1.6) 318. FDA reviewers said the smaller gap likely reflected risk-mitigation measures used in CREDENCE 329. FDA's August 26, 2020 Drug Safety Communication gave the public rationale: newly identified heart- and kidney-related benefits significantly enhanced the benefit of canagliflozin, and the amputation risk, while still increased, was lower than previously described when patients were monitored. Lower-limb amputation stayed as Warnings and Precautions section 5.1, with instructions to assess risk factors, monitor for infection or ulcers, and stop the drug if these occur 333.

Avandia (rosiglitazone): REMS and box narrowed after the RECORD readjudication, 2013 to 2014

By 2011, the Avandia box covered congestive heart failure and myocardial infarction. The drug was available only through a restricted access program 153. On November 25, 2013, FDA used section 505(o)(4) to require safety labeling changes reflecting ischemic cardiovascular risk "as assessed by the readjudicated results" of the RECORD trial 155.

The resulting supplement, approved May 7, 2014, removed the access-program language from the box and the patient-population restrictions from Indications and Usage. The same action approved a modified REMS: the restricted prescriber, pharmacy and patient requirements were dropped, and the remaining REMS consisted of health-care-provider training. FDA eliminated the REMS entirely on December 16, 2015 (NDA 021071/S-050 approval letter). The remaining boxed warning addressed congestive heart failure only 362363. The retrieved records do not report the readjudication's numerical findings.

Category 4: Removal through FDA class-wide labeling reassessment

In several recent cases, FDA itself requested removal after comparing labeling across a drug class. The sponsor submitted no new safety data.

  • Avastin (bevacizumab), June 2019: the box for GI perforation, wound-healing complications and hemorrhage was removed, and that content moved into Highlights and Warnings and Precautions 131. FDA found that VEGF-inhibition risks were similar across the class. Postmarketing experience with other VEGF inhibitors that had no boxed warning showed no unacceptable toxicity 3173. Genentech submitted no new clinical or safety data 73.
  • Cometriq (cabozantinib), January 2020: the box for perforations, fistulas and hemorrhage was removed because comparable VEGFR inhibitors had no box and there was no evidence that patients on those drugs faced greater risk 32. The sponsor also submitted a global safety database search (1,214 surgical or procedural cases, narrowed to 186) and a literature review 289291. FDA found the wound-healing data too limited to set a drug-specific restart interval 291. The label adopted class-based withholding guidance instead: at least three weeks before elective surgery and two weeks after major surgery 292.
  • Yervoy (ipilimumab), June 2020: the box for immune-mediated adverse reactions was removed after a reassessment of PD-1/PD-L1 labeling, none of which carried such a box 236241. The "evidence" was accumulated clinical experience. FDA concluded that oncologists could now recognize and manage these toxicities, and that Warnings and Precautions was adequate. No new data were submitted 334335.
  • Older labeling clean-ups: Erbitux (2007) cut its boxed warnings down to the most critical elements 7. Doxil (2015) dropped myelosuppression, hepatic dose reduction and accidental substitution from its box because they did not reach boxed-warning severity 83. Fludarabine (2024) moved its box content to Warnings and Precautions to align with current labeling practice, based on a review of existing safety data and published literature 228.

Category 5: Narrowing to a specific population or condition of use

  • Promacta (eltrombopag), February 2014: the general hepatotoxicity box was narrowed to hepatic decompensation in chronic hepatitis C patients receiving interferon and ribavirin. This took ITP patients out of the box, while liver enzyme elevations stayed in Warnings and Precautions 2512033. The sponsor pointed to accumulated clinical-trial and postmarketing experience. FDA found no new or emerging safety issues and concluded the REMS communication plan was no longer needed 203341.
  • Addyi (flibanserin), 2019: the box was kept but revised. The absolute alcohol prohibition became a timing-based restriction: alcohol must be stopped at least 2 hours before the bedtime dose 12108. The evidence came from postmarketing alcohol-interaction studies. In one, 64 women drank about two drinks 2, 4 or 6 hours before dosing and had hypotension rates similar to controls 168170. A concurrent-dosing PMR in 96 women showed missing orthostatic measurements that rose with alcohol dose. FDA read this as evidence that the concurrent-use risk was real 160164.
  • Soriatane (acitretin), 2003: non-teratogenicity content was removed from the box and the pregnancy box was kept. The record says this was not based on new "improved" safety data 63.
  • Menopausal estrogen products: in 2019, Divigel's box was revised to state that the WHI estrogen-alone findings came from daily oral 0.625 mg conjugated estrogens only, and that their relevance to other doses and routes is unknown 95. Labeling revisions dated February 12, 2026 went further. The cardiovascular disorders, breast cancer and probable dementia components were removed from the boxes of Cenestin, Enjuvia and Divigel, leaving only the endometrial cancer box for unopposed estrogen 125126127. Bijuva's box was removed entirely 130. Those risks remain in Warnings and Precautions and Contraindications 125130. The change was not yet uniform: EstroGel's May 2026 label still carried the broad box 132. The retrieved labeling does not state FDA's evidentiary rationale 125130.

Summary of precedents

ProductYearChangeMain evidence type
Chantix2016Neuropsychiatric box removedPMR randomized trial (EAGLES, n=8,144) and advisory committee 284472
ICS/LABA (Advair, Symbicort and others)2017Asthma-related death box removedFour PMR noninferiority trials plus FDA meta-analysis 45305
Forteo2020Osteosarcoma box removedCase series, registry, two claims cohorts 348349356
Invokana/Invokamet2020Amputation box removedCREDENCE plus a benefit-risk reassessment (new heart and kidney benefits; amputation risk still increased but lower when monitored) 318332
Avandia2014Access program removed from box; REMS modified (eliminated December 2015)RECORD readjudication under 505(o)(4) 155362
Avastin2019Box removedFDA class reassessment of VEGF inhibitors 3173
Cometriq2020Box removedClass consistency, safety database and literature review 32289
Yervoy2020Immune-mediated reactions box removedClass harmonization with PD-1/PD-L1 labels, clinical experience 334
Promacta2014Box narrowed to HCV populationAccumulated trial and postmarketing experience 2033
Addyi2019Alcohol box revised to timing restrictionPostmarketing alcohol-interaction studies 108168
Estrogen products (selected)2026Cardiovascular, breast cancer and dementia elements removedRationale not in retrieved labeling 125130

Practical takeaways for sponsors

  1. Match the evidence to the original signal. Removals based on randomized trials (Chantix, ICS/LABA) used trials designed around the exact endpoint that prompted the box. They used adjudicated composite endpoints and, for ICS/LABA, prespecified noninferiority margins 302285. Pooled analyses of older trials that did not collect the events systematically were given little weight 26.
  2. Rare-event risks can be addressed with epidemiology. For osteosarcoma, FDA accepted a set of case series, a registry and claims cohorts even though the registry was underpowered, because every source pointed the same way 349.
  3. Class consistency is a real argument. When comparable products carry similar risks with no box and postmarketing experience shows no excess harm, FDA has removed boxes on its own initiative 3132334.
  4. Expect the risk to stay in the label. In the removal cases, the underlying risk stayed in Warnings and Precautions, often with new detail, monitoring instructions or trial data 28298333361. Where FDA only narrowed the box, part of the risk stayed in the box itself (Avandia congestive heart failure; Addyi alcohol timing).
  5. Plan for REMS and restrictions at the same time. Box changes often came with REMS release or relaxed restrictions (Avandia, Promacta) 36233.
  6. Advisory committees help but are not required. Chantix went to a joint advisory committee vote 72. The retrieved record for the 2017 ICS/LABA decision shows no advisory committee vote on removal 306.

Topics that deserve a closer look include the RECORD readjudication results behind the Avandia change, FDA's stated rationale for the 2026 menopausal hormone therapy labeling, and whether the remaining estrogen products have since followed the same path.

Rhizome did this research. Let it help you with your most critical decisions by creating a free account.