Rhizome

Early CAR-T and T-Cell Engager Trials in Autoimmune Disease: Where They Opened and Pre-Dosing Requirements

Chetan Mishra
Chetan Mishra
Sep 29, 2026

Engineered CAR-T cells and CD3-based T-cell engagers are moving from oncology into lupus, systemic sclerosis, myositis and other B-cell-driven autoimmune diseases. Sponsors planning first-in-human studies have to decide where to open sites and how to build a pre-dosing package that regulators will accept. That is harder than in oncology, because the patients are not facing terminal disease and much of the existing guidance was written for cancer indications.

The analysis below maps early autoimmune CAR-T and T-cell engager trials registered in Germany, Australia, China and the United States by modality, sponsor and registry date. It then compares what each jurisdiction's regulators expect before first dosing: who authorises the trial, quality and nonclinical requirements, how the starting dose is justified, staggered dosing, and how gene-technology or GMO oversight applies.

Want Rhizome's help on your own question? Try it for free.

CAR-T and T-cell engagers in autoimmune disease: where early trials opened and what regulators expect before first dosing

Engineered T-cell therapies and CD3-based T-cell engagers (TCEs) have moved from oncology into lupus, systemic sclerosis, myositis, rheumatoid arthritis and other B-cell-driven autoimmune diseases. Across Germany, Australia, China and the United States, the registries show one pattern. The earliest registered start in this set is an academic study in China (NCT05030779, estimated start 10 Sep 2021). In Germany the earliest registered starts are industry-sponsored: Kyverna's KYSA-3 (1 Dec 2022) and Miltenyi's CASTLE study at Erlangen (July 2023). Other US and multinational industry programmes followed from 2023. Australia is taking part through industry-sponsored multiregional studies that also need gene technology licensing. TCEs started later, from late 2024, as academic studies in China and industry and academic studies in the EU and US.

The pre-dosing requirements differ in structure more than in scientific substance. All four regulators expect a risk-based quality and nonclinical package, a justified starting dose and staggered early dosing. The differences lie in who authorises the trial, how GMO aspects are handled, and whether the guidance was written for oncology.

For the general first-in-human authorisation routes in the US, China and Australia, see Starting a first-in-human trial: how FDA (IND), China's NMPA, and Australia's CTN/CTX schemes compare.

Registry snapshot: early autoimmune CAR-T and TCE trials by country

The dates below are registry start or decision dates. They are not verified first-patient-dosed dates. Few records describe themselves as first-in-human.

CountryModalityTrial (registry ID)Sponsor / productIndicationRegistry date
ChinaCAR-TNCT05030779Zhejiang University; CD19/BCMA CAR-T 271Refractory SLE 271Start 10 Sep 2021 (estimated; record status unknown); site Hangzhou 271195
ChinaCAR-TNCT05459870Shenzhen Geno-Immune Medical Institute; 4th-generation lentiviral CD19 CAR with inducible caspase-9 safety switch 294295B-cell-related autoimmune diseases 294Not yet recruiting; estimated start 1 Jun 2027; site Shenzhen 294192
ChinaTCENCT06747156Ruijin Hospital; ABO2203, mRNA encoding a CD19/CD3 TCE 421Refractory autoimmune diseases incl. SLE/LN, RA, SSc, IIM 422Start 23 Dec 2024; sites include Shanghai, Nanjing and Wuhan 421116
ChinaTCENCT06900010Shandong First Medical University; CM336, BCMA/CD3 bispecific 420Autoimmune bullous disease 420Start 22 Apr 2025; Jinan 420117
GermanyCAR-TNCT06342960 (KYSA-3)Kyverna; KYV-101 anti-CD19 CAR-T 267Refractory lupus nephritis 267Start 1 Dec 2022; sites in Berlin, Dresden, Düsseldorf, Erlangen, Frankfurt, Hamburg 267177; later terminated (sponsor decision; registry verified Aug 2026)
GermanyCAR-TNCT06347718Miltenyi Biomedicine (CASTLE; PI at Universitätsklinikum Erlangen); lentiviral CD19 CAR-T 416417SLE, SSc, dermatomyositis, polymyositis 416Start 17 Jul 2023; Erlangen 416212
GermanyCAR-TEU CT 2024-514955-13-00 (COMPARE)Charité; KYV-101 vs rituximab 309ACPA-positive refractory RA 309CTIS decision 1 Nov 2024 309
GermanyCAR-TEU CT 2024-519592-26-00 (HD-CAR-ILD-1)Heidelberg University Hospital; 3rd-generation retroviral CD19 CAR-T 328331Autoimmune-associated progressive ILD 331CTIS decision 3 Aug 2026 331
Germany / EUTCEEU CT 2025-523061-22-00Universität Leipzig; blinatumomab 717GPA, SLE, SSc 717CTIS decision 26 Sep 2025 717
Germany / EUTCEEU CT 2025-522857-20-00Fraunhofer ITMP; cizutamig (BCMAxCD3) 715730Sjögren's, IIM, SSc, RA 715CTIS decision 28 Nov 2025 715
EUTCEEU CT 2025-520666-22-00BMS; BMS-986528 (CD19xCD3), classified as first administration to humans 735Refractory RA 735CTIS decision 22 Jul 2026 735
USCAR-TNCT05938725 (KYSA-1)Kyverna; KYV-101 255Refractory lupus nephritis 255Start 28 Apr 2023; six US academic sites 255178; later terminated (sponsor decision; registry verified Aug 2026)
USCAR-TNCT06340750Luminary; LMY-920 BAFF-ligand CAR-T 286Refractory SLE 286Start 1 Apr 2025; Columbus, Ohio 286228
US, Europe, Australia and othersTCENCT06570798Amgen; blinatumomab and inebilizumab platform 254SLE/LN and refractory RA 254Start 16 Jul 2025; sites in the US, Belgium, France, Germany, Italy, Spain, the UK, Australia and other countries 254123
Australia, US, CanadaCAR-TACTRN12625000707460 / NCT07038447Kite; KITE-363 autologous CD19/CD20 CAR-T 364275SLE ± LN, SSc, IIM 364NCT start 2 Jul 2025; ANZCTR registration 3 Jul 2025; sites include Concord (Sydney), St Vincent's (Fitzroy), and US and Canadian centres 364132
AustraliaCAR-TDNIR-717PPD Australia (licence holder); CB-010, CRISPR-edited allogeneic anti-CD19 CAR-T 833Refractory SLE 833OGTR licence 25 Mar 2025; now surrendered 833
Australia, US, GermanyCAR-TNCT07115745 / DNIR-735BMS; BMS-986515, healthy-donor allogeneic CD19 CAR-T 284423SLE, IIM, SSc, RA 284Start 4 Sep 2025; the Camperdown, Brisbane and Clayton sites are withdrawn; recruiting sites include Düsseldorf and other German centres and US centres 284217; OGTR licence 6 Nov 2025 423

Other points from the registries:

  • A second Kite programme in Australia covers multiple sclerosis, myasthenia gravis and CIDP. It was registered on 2 Dec 2025 365. No autoimmune TCE trial was found on ANZCTR, but Amgen's platform study (NCT06570798) lists a recruiting site in Perth.
  • In China, three CAR-T products for refractory SLE hold CDE clinical-trial implied-permission records, as distinct from hospital-registered investigator-initiated studies. The three are a CD19-targeted non-viral PD1-specific CAR-T from Shanghai Bangyao 744, ICG318 748, and a CD19/CD22 CAR-T from Shanghai Pharmaceuticals Group Biotherapy 756. The records do not carry dates.
  • In CTIS, the Leipzig and Fraunhofer TCE trials list Germany as their only location, and the BMS TCE trial lists Germany, Spain, Poland and Italy 834835836.
  • The industry studies are mostly not first-in-human in the strict sense. For example, the Breakfree-SLE protocol for CC-97540 states that the product had already been tested in a Phase 1 autoimmune study 338. The COMPARE protocol cites a separate first-in-human lymphoma study of the same CAR construct as KYV-101 301.

United States: FDA/CBER

Gate to first dosing. A cell or gene therapy IND generally takes effect 30 calendar days after FDA receives it. Dosing can start then unless FDA imposes a clinical hold. FDA can also tell the sponsor earlier that the study may proceed 686. CBER recommends early contact before an IND is filed:

  • An INTERACT meeting suits novel products once proof-of-concept work exists but before definitive nonclinical studies begin 687691.
  • A pre-IND meeting covers nonclinical design, the initial clinical study, and manufacturing 687.

CAR-T products. FDA's January 2024 CAR T guidance is written for oncology. It tells sponsors developing non-oncology indications, which include autoimmune disease, to discuss product-specific issues with OTP/CBER before submitting the IND 567. Within that framework the IND must show the following.

  • CMC. Stage-appropriate CMC data are required, as follows:
    • vector characterisation and lot release covering safety, identity, purity and biological activity 579
    • adventitious-agent and microbiological testing 579
    • control of CQAs, with assays for identity, purity and potency 566559
    • a potency readout for each target of a multi-antigen CAR 571
  • Retroviral and lentiviral vectors. These fall under FDA's RCR guidance. It recommends RCR testing at several points during vector production 517523.
  • Nonclinical package. It must cover on-target/off-tissue and off-target binding, and it must show that the cells do not signal or proliferate without antigen 561556. For allogeneic products it must also address GVHD and host rejection 556.
  • Clinical design.
    • The starting dose should not rest only on animal data, because CAR T cells expand in vivo 555.
    • Staggered enrolment is recommended for a first-in-human product or one with limited human experience 562.
    • DLTs should be defined without regard to attribution to the product 575.
    • Stopping rules might include more than two Grade 4 CRS events for a first-in-human CAR T product, or any death within 30 days of dosing 575.
  • Long-term follow-up. Subjects who receive CAR T cells with an integrated transgene should be followed for 15 years 558.

T-cell engagers. FDA's 2021 bispecific antibody guidance sets the following expectations:

  • Sponsors should assess homodimers of anti-CD3 constructs, because they can trigger cytokine release 585.
  • For agonistic bispecifics, sponsors should consider a MABEL-based first dose and discuss dose selection with the review division 583.
  • The guidance cites an analysis of 17 CD3 bispecifics in which a first-in-human dose giving 10 to 30% pharmacological activity was acceptable 583.
  • Healthy volunteers may be unsuitable for these studies 583.

A June 2026 draft guidance on QSP-based MABEL takes a conservative line. Where estimates diverge, sponsors should use the lowest one for novel targets. It also recommends safeguards such as staggered enrolment and intensive monitoring 589.

Germany: PEI or BfArM under EU CTR and the AMG

Gate to first dosing. A trial may start only once the competent federal authority has authorised it under Article 8 of Regulation (EU) 536/2014. The application goes through the EU portal. The ethics committee's assessment binds the authority on the matters assigned to it 633635. Other national conditions in the AMG:

  • For purely national trials, or trials run in Germany and third countries, the sponsor or a sponsor's representative must be established in the EU/EEA 634.
  • Subject insurance is required, with at least EUR 500,000 per case of death or permanent incapacity 634.
  • Consent must meet AMG § 40b 638.

Which authority. Under AMG § 77, the Paul-Ehrlich-Institut is competent for ATMPs, which include gene therapy medicinal products such as CAR-T 467. PEI describes CAR-T cells as gene therapy 536. Monoclonal antibodies are not among PEI's listed categories, so BfArM is competent by default unless a product is reassigned 467. This means antibody-format TCEs would normally go to BfArM.

GMO overlay for CAR-T. Where the investigational product consists of or contains GMOs, the sponsor must add the following to the application:

  • a GMO risk assessment
  • an environmental assessment
  • a monitoring plan
  • information on residues
  • emergency plans

The authority consults the Federal Office of Consumer Protection and Food Safety (BVL). The trial authorisation then includes authorisation to release the GMO within the trial 633634.

Scientific expectations (EMA investigational ATMP guideline).

  • GMP specific to ATMPs is a prerequisite for the trial 615.
  • Most nonclinical data should be available before first administration 618619. The minimum package is:
    • proof of concept
    • support for a safe starting dose
    • biodistribution and persistence data
    • an assessment of insertional mutagenesis for integrating vectors
    • an assessment of tumourigenicity
  • Administration should be staggered between subjects. The waiting period should reflect the timing of toxicity seen in animals and in human experience with related products 623.

For TCEs, the EMA first-in-human guideline (Rev. 1, 2018) sets these expectations:

  • The starting dose should be anchored to MABEL, PAD or NOAEL, with justified safety factors 600596.
  • A single subject normally receives the first dose, and the rest of the cohort is dosed in sequence 603.
  • The next cohort should not be dosed until the previous cohort's data have been reviewed 603.

The 2007 version of the guideline flagged immune targets that can drive cytokine cascades, such as CD3 or CD28 super-agonists, for special attention 597.

Hospital exemption. AMG § 4b allows some non-routinely manufactured ATMPs to be used without a marketing authorisation, under PEI approval and GMP. PEI still stresses that clinical trial data remain important 536.

Australia: TGA, OGTR and HREC in parallel

TGA gate. Under the CTN scheme (Schedule 5A item 3 of the Therapeutic Goods Regulations):

  • The sponsor, or the organisation conducting the trial, approves it after considering the ethics committee's advice 788.
  • The sponsor must notify the Secretary before the goods are first used in the trial, and again for each additional site 788799.

Under the CTA pathway, the approval holder and each principal investigator must give written GCP assurances and undertakings to the Secretary before trials start 787. Under either scheme, use must follow an ethics-approved protocol, the GCP guideline and the National Statement. Use must stop if the ethics committee advises it is inconsistent with the approval 509.

OGTR gate for CAR-T. Whether a CAR-T trial needs a licence depends on the product and on whether manufacture takes place in Australia.

  • Administering GM somatic cells counts as an exempt dealing, with no OGTR licence needed, if all of the following apply (Schedule 3, Part 3.1(n) of the Gene Technology Regulations 2001) 426431:
    • the cells cannot produce infectious agents
    • no viruses able to recombine with the GM nucleic acid were detected in testing
    • the viral vector is no longer present in the cells
  • If any of these conditions is not met, the trial needs a GMO licence 426427.
  • Manufacturing with a replication-defective lentiviral or retroviral vector cannot proceed as an NLRD. It needs its own authorisation, even if the final infusion qualifies as exempt 426431.

Autoimmune programmes have in practice obtained DNIR licences. DNIR-717 covered CB-010 in SLE (issued 25 Mar 2025, now surrendered) 833. DNIR-735 covered BMS-986515 in severe refractory autoimmune diseases (issued 6 Nov 2025) 423.

HREC gate. The National Statement requires the following for trials like these:

  • Risks must be weighed against the risks of the condition and of usual care 453.
  • Safety monitoring must be proportionate to risk. A DSMB is recommended and in some cases required 456457.
  • The trial must be registered publicly before the first participant is recruited 453.

China: CDE implied approval, plus a large investigator-initiated sector

Gate to first dosing (registration pathway). NMPA Announcement No. 50 of 2018 set up a 60-day implied (tacit) approval system for clinical trial applications 821826. The 2019 Drug Administration Law (Article 19) now sets the period at 60 working days. CDE guidance describes pre-IND communication as required before a Phase I application 819. The CDE implied-permission records for SLE CAR-T products noted above went through this route 744748756.

Many of the earliest Chinese autoimmune CAR-T and TCE studies are hospital-sponsored and registered on ClinicalTrials.gov, for example at Zhejiang University, Ruijin Hospital and Shandong First Medical University 271421420. The national rules for investigator-initiated clinical research were not in the sources reviewed here. The regulatory basis for those studies should be checked separately.

CAR-T expectations. CDE's cell therapy guidance is mostly written for oncology:

  • a 2020 draft pharmaceutical guideline for immune cell products 649
  • a 2024 clinical pharmacology guideline for cell therapy 646
  • 2024 CAR-T clinical guidelines for haematological malignancies 647651

The 2020 draft clinical guideline for immunotherapy products is the most directly relevant. It says cohort sizes in trials for non-malignant indications should reflect that population's risk tolerance, and that larger samples may be needed for safety assessment 546. The 2024 cell therapy clinical pharmacology guideline adds two points 545:

  • Interactions with immune-modulating co-medications should be assessed.
  • The effect of lymphodepletion on cell kinetics should be considered.

CDE also expects the following for CAR-T:

  • ongoing monitoring for clonal expansion and secondary T-cell tumours 664
  • a multidisciplinary safety panel for trial safety issues 664

The CDE CAR-T guideline does not set a numerical long-term follow-up period 664.

TCE expectations. CDE's 2025 guideline on antibody clinical pharmacology says MABEL should be the priority method for high-risk antibodies. That covers antibodies with:

  • immune-agonist activity
  • novel mechanisms
  • cascade-amplification effects

Where methods give different starting doses, the sponsor should choose the lower one 488497. The 2022 guideline on bispecific antitumour antibodies has a section on risk control in first-in-human trials 486505. CDE's immunogenicity guidance supports staggered dosing between individuals and cohorts, and PK/PD review before dose escalation 503. CDE's guideline on immune-related adverse events sets no CRS-specific operational rules for TCEs 506.

Comparative takeaways for regulatory strategy

RequirementUS (FDA)Germany (PEI/BfArM, EU CTR)Australia (TGA/OGTR/HREC)China (CDE)
Authorisation modelIND effective after 30 days unless on hold 686Explicit authorisation via EU portal, with a binding ethics committee assessment 633635CTN notification before first use, or CTA; approval by sponsor or institution after HREC advice 78878760-working-day implied approval (2019 Drug Administration Law, Art. 19); pre-IND communication for Phase I 819821
CAR-T competent bodyCBER/OTP 567PEI 467TGA plus OGTR 426CDE 649
GMO handlingWithin the IND (RCR testing, LTFU) 523558GMO environmental dossier; BVL consulted; release authorised within the trial 633634Exempt dealing if Part 3.1(n) conditions are met, otherwise a DNIR licence 426423None identified
Autoimmune-specific guidanceNone; talk to OTP before the IND 567None identified; ATMP guideline applies 614None identifiedNon-malignant cohort sizing in the 2020 draft 546
TCE starting doseMABEL; 10 to 30% activity precedent for CD3 bispecifics 583MABEL/PAD/NOAEL with safety factors; sentinel dosing 600603None identifiedMABEL priority; choose the lower estimate 488
StaggeringRecommended for first-in-human CAR-T 562Required in principle for ATMPs and first-in-human trials 623603DSMB recommended 456Staggering supported where warranted 503

Two practical points follow for sponsors.

  • Guidance gap. In the sources reviewed, none of the four regulators has final guidance written specifically for autoimmune CAR-T or TCE programmes. Both the FDA and CDE CAR-T frameworks are oncology-based. FDA explicitly sends non-oncology sponsors to pre-IND discussion 567647.
  • GMO pathway. This is the main cross-border difference for CAR-T. Germany folds GMO release into the trial authorisation 634. Australia runs a separate OGTR track, where licensing depends on whether the final product meets the somatic-cell exemption conditions and where manufacture takes place 426.
Want Rhizome's help on your own question? Try it for free.