The point of departure chosen for a toxicological risk assessment drives the acceptable intake, permitted daily exposure or health-based exposure limit that a sponsor must justify to regulators. For impurity qualification, shared-facility cleaning limits and nonclinical safety packages, choosing between a NOAEL and a benchmark dose lower confidence limit can change the resulting limit. It also changes how much justification reviewers will expect.
The analysis below explains how BMD modeling differs from the NOAEL approach and where FDA, EMA, VICH and ICH guidance place each method. It also covers the regulatory precedents and documents in which benchmark dose modeling has been accepted or recommended for setting exposure limits.
Benchmark dose (BMD) modeling vs. NOAEL in regulatory toxicology and impurity risk assessment
Benchmark dose modeling appears in several of the main impurity and exposure-limit frameworks that regulatory affairs teams work with, in most of them as an accepted alternative point of departure (PoD). The one clear exception is the EMA's 2026 reflection paper on non-mutagenic impurities, which calls the benchmark dose lower confidence limit (BMDL) the scientifically preferred option. This article summarizes how BMD differs from the NOAEL approach, where each regulator and guideline stands, and what precedents exist.
How a BMD point of departure differs from a NOAEL
A NOAEL is the highest tested dose at which no critical effect is observed. EMA's shared-facilities guideline defines it that way and requires that one be established for every critical effect identified 113. The PoD is therefore constrained to one of the doses actually tested, and it depends on study design.
BMD modeling instead fits a dose-response model and reports the dose associated with a specified low response. The VICH GL54 glossary (reproduced in FDA's CVM GFI #232) defines the benchmark dose as a dose associated with a specified low incidence of response, generally 1 to 10%, or with a specified change in a biological effect 22. The BMDL is the lower one-sided confidence limit on that dose 125. EMA's 2026 reflection paper on non-mutagenic impurities (NMIs) gives the practical argument. A BMDL "makes use of all data on the dose-response curve and is the preferred option from a scientific point of view," whereas an experimentally defined NOAEL "generally provides a less accurate PoD" 118119.
A BMDL is a PoD, not a limit. Uncertainty or modifying factors, or low-dose extrapolation, are still applied to it. The ICH Q3D(R2) glossary describes the safety factor as being applied to the NOAEL "or other reference point, such as the benchmark dose or benchmark dose lower confidence limit" 30.
How each framework treats BMD
| Framework | Position on BMD relative to NOAEL |
|---|---|
| ICH M7(R2), mutagenic impurities | BMDL10 may be used instead of TD50 as the carcinogenic potency index. Linear extrapolation to 1 in 100,000 is then BMDL10 divided by 10,000 662829. |
| ICH Q3D(R2), elemental impurities | The glossary treats the benchmark dose or BMDL as an alternative reference point to the NOAEL 30. |
| ICH Q3C, residual solvents | The Q3C appendix and the EMA's Q3C(R6) support document report BMDs calculated at 10% incidence, with 95% confidence limits, for a sperm-count endpoint (31 mg/kg per day) 32131. |
| ICH Q3E (draft), extractables and leachables | A worked example selects a BMDL1SD as the PoD 164. |
| EMA shared-facilities guideline (2014) | "Alternative approaches to the NOAEL such as the Benchmark dose may also be used" 111. |
| EMA reflection paper on NMI qualification (2025, 2026) | The BMDL is preferred. A NOAEL is the fallback and a LOAEL the last resort 120. |
| FDA CVM GFI #3 | NOEL/NOAEL or BMDL is the PoD for the toxicological ADI 25. |
| FDA CVM GFI #232 and VICH GL54 (ARfD) | The PoD is "typically identified as a NOAEL dose or benchmark dose lower confidence limit (BMDL)" 21124. |
| FDA CVM GFI #115 and VICH GL22 (reproduction testing) | BMD can be an alternative to the NOAEL, and study design (dose selection, group number, animals per group) should be considered accordingly 20. |
Mutagenic impurities: ICH M7 and nitrosamines
ICH M7 uses BMD in a narrow but important way. For a known mutagenic carcinogen, a compound-specific acceptable intake is calculated from carcinogenic potency by linear extrapolation as the default approach 60. The guideline allows the default TD50 to be replaced with a benchmark dose "to better take into account directly the shape of the dose-response curve" 66. It also allows an expert assessment to select the most human-relevant tumor finding as the reference point for extrapolation 66.
Where a practical threshold exists, M7 describes a NOEL-based approach rather than BMD. It uses a NOEL with uncertainty factors to derive a PDE, following Q3C(R5), and notes that the terminology there is NOEL, not NOAEL 6768.
For N-nitrosamines, which M7 places in the "cohort of concern", M7 calls for a case-by-case approach, using for example carcinogenicity data from closely related structures 87. FDA's guidance on nitrosamine drug substance-related impurities (NDSRIs) sets recommended acceptable intake limits through a potency-category approach, with categories from 26.5 ng/day to 1500 ng/day 777881. That guidance does not describe BMD modeling. It does allow a higher AI limit supported by compound-specific data or by read-across to a suitable surrogate that maintains a 1 in 100,000 cancer risk estimate 8586.
BMD does appear in the published literature on NDSRIs. Published papers describe mutation-based BMD modeling as a robust, precise PoD metric for impurities that lack carcinogenicity data. They propose comparing lower-bound BMD confidence intervals with those of anchor nitrosamines to derive potency-based acceptable intakes 297298. One paper also argues for BMD-based assessment over simple linear extrapolation when setting nitrosamine PDEs 306. Another compares BMD with TD50 rather than with NOAEL, and reports that class-default potency metrics changed little and read-across-relevant estimates differed by no more than threefold 305. These are peer-reviewed proposals, not regulatory requirements.
Non-mutagenic impurities: the EMA reflection paper
The EMA's reflection paper on the qualification of non-mutagenic impurities is the most explicit regulatory statement favoring BMD. Two versions appear: one dated 30 January 2025 (EMA/CHMP/543397/2024) and one dated 2 February 2026 (EMA/CHMP/4299/2026) 9299110117. The 2025 text was the draft released for public consultation (30 January to 30 April 2025). The 2026 text is the version CHMP adopted in January 2026.
The 2025 text says several authorities consider BMD "a scientifically more advanced method for deriving a PoD" than the NOAEL approach 114. It allows the PoD to be a BMDL, a NOAEL or, in their absence, a LOAEL, and recommends the 2022 EFSA BMD guidance principles on dose selection 115116.
The 2026 text goes further. Its main points are:
- PoD hierarchy: use a reliable BMDL, then a NOAEL if no reliable BMDL can be derived, then a LOAEL if no NOAEL has been established 120. The hierarchy feeds a product-specific acceptable level (AL), which the paper distinguishes from a generally applicable PDE.
- Modeling qualifiers: assess the critical effect size, the number of dose groups, the BMD credible interval (BMDL to BMDU) and the ratio of the BMDL to the lowest dose 120.
- Assessment factors: AF1 (interspecies), AF2 (intraspecies), AF3 (study duration), AF4 (severity of toxicity) and AF5 (absence of a BMDL or NOAEL) 253. The adopted 2026 text also divides by AF6 (route-to-route bioavailability) and AF7 (uncertainty from surrogate or read-across data). If a BMDL is chosen and sufficiently justified, AF5 is 1 121. A high AF4 (severity) value "up to 10" should be considered where a LOAEL showing a severe effect is used without a BMDL or NOAEL 258.
- BMR selection: the paper points to WHO EHC 240 and EPA's 2012 Benchmark Dose Technical Guidance for choosing the benchmark response, and does not prescribe a numerical value 260.
- Guidance gap: the paper says no dedicated EMA or ICH guidance exists on deriving a BMDL as a PoD for an impurity acceptable level, and points to EFSA's 2022 guidance 261.
Extractables and leachables: ICH Q3E (draft)
The draft ICH Q3E guideline selects a PoD, then applies modifying factors F1 to F7. F1 and F2 cover inter- and intraspecies variability, F3 covers study duration, F4 severity and F5 the absence of a NOAEL, with F6 added for route-to-route bioavailability and F7 for surrogate or read-across uncertainty 401406411.
The guideline's worked benzo[a]pyrene example is the clearest BMD precedent in ICH text. BMD modeling of three neurodevelopmental endpoints gave BMDL1SD values of 0.092 to 0.16 mg/kg-day, and the lowest, 0.092 mg/kg-day, was selected as the PoD 164. With F5 set to 1 for the BMDL, the chronic PDE calculates to 2.6 µg/day 171173. The guideline text does not state a general preference for BMD over NOAEL. Treat the example as illustrative and check the final adopted text when it is available.
Shared-facility exposure limits and cleaning validation
EMA's 2014 shared-facilities guideline builds the PDE as NOAEL times a weight adjustment, divided by adjustment factors F1 to F5 194195. It allows a LOAEL where no NOAEL is obtained 113. It also states that the benchmark dose may be used as an alternative to the NOAEL, and that other approaches can be acceptable if scientifically justified 111112. By default the lowest of several candidate PDEs is used 197. For cross-contamination limits, BMD is therefore a permitted alternative, not a requirement.
Veterinary residues and other precedents
FDA's CVM guidance lists NOAEL and BMDL as alternative PoD options for the toxicological ADI and the ARfD 2521. GFI #232 cites EPA's BMDS and EFSA's 2009 BMD guidance as references 238889. EMA has similar wording on the pharmacological ADI, where a threshold is "a No Observed Effect Level (NOEL) or a Benchmark Dose (BMDL)" 127.
EMA's supporting report for its boric acid and borates Q&A is an example of a substance-specific comparison. It reports a lowest BMDL05 of 10.3 mg B/kg/day for fetal body weight, which it describes as similar to the 9.6 mg B/kg/day NOAEL from the underlying study 128129.
FDA's own drug review files include BMD-based derivations. The Drugs@FDA review for Kalydeco (ivacaftor, NDA 203188) contains benchmark analyses for a substance whose identity is redacted. For mouse follicular-cell hyperplasia, the smallest BMDL10adj of 22 mg/kg/day was the PoD and the reference dose was 220 µg/kg/day 440441. For female rat kidney weight, a BMDL10 of 133 mg/kg/day gave a reference dose of 1.33 mg/kg/day, set against a possible LOAEL of 175 mg/kg/day 443. The review excerpts do not show whether the substance is an impurity or label this as an impurity qualification. Cite it only as an example of reviewers working with BMD.
Medical devices: the TRA route and its limits
For devices, FDA recognizes ISO 10993-17 in part, and the recognition is moving between editions. The 2002 edition (recognition 2-237) covers establishing allowable limits for leachable substances. The 2023 second edition (recognition 2-303) is titled "Toxicological risk assessment of medical device constituents" 323333. FDA states that 2-303 supersedes 2-237, and declarations of conformity to 2-237 will be accepted until December 20, 2026 321.
FDA's draft guidance on chemical analysis for biocompatibility assessment (September 2024) ties chemical characterization to toxicological risk assessment under the FDA-recognized ISO 10993-17 459. It also warns that cohort-of-concern compounds should be investigated even below a TTC-based reporting threshold 462. That draft guidance does not describe how to derive a tolerable intake, and does not mention NOAEL or BMD. The 510(k) and De Novo summaries examined for this article did not document a BMD-derived tolerable intake. For devices, a BMD-derived intake would need a documented rationale within the ISO 10993-17 toxicological risk assessment, with ICH Q3E and the EMA reflection paper as the closest regulatory analogies.
Practical points for submissions
- Study design: BMD works best with several dose groups and a graded response. VICH GL22, as adopted by FDA's CVM, tells sponsors who intend BMD to plan dose selection and group sizes accordingly 20. EMA's 2026 text checks the number of dose groups and the BMDL-to-lowest-dose ratio 120.
- Model and BMR justification: document the benchmark response, model fit and confidence interval. EMA says no dedicated EMA or ICH guidance exists for impurity BMDL derivation, so cite EFSA 2022, EPA 2012 and WHO EHC 240 260261.
- Fallbacks: keep the NOAEL or LOAEL derivation available. EMA's hierarchy and AF5 logic assume a reliable BMDL may not be available 120121.
- Data sufficiency: the literature notes that BMD does not remove data-adequacy constraints. One occupational nitrosamine study applies BMD only where data are adequate and uses read-across otherwise 295.
- Do not conflate comparators: in M7 the BMD replaces TD50, not the NOAEL 66. Threshold-mechanism PDEs under M7 still use NOEL and uncertainty factors 67.
Summary
BMD appears across ICH M7, Q3D, Q3C and the draft Q3E, in EMA's shared-facilities guideline and non-mutagenic impurity reflection paper, and in FDA's CVM veterinary-residue guidances. In most of these it is an accepted alternative PoD. The 2026 EMA NMI reflection paper is the strongest statement of preference 119. None of these sources makes BMD mandatory.