# FDA Evaluation of Host Cell Protein and Residual DNA Controls in BLA Reviews for Monoclonal Antibodies and Recombinant Proteins

How FDA reviewers have assessed host cell protein and residual DNA limits, HCP assay coverage, and related postmarketing commitments in BLAs for therapeutic proteins.

Published by Rhizome AI on 2026-10-15. Web version: https://rhizomeai.com/articles/fda-evaluation-of-host-cell-protein-and-residual

## FDA evaluation of host cell protein and residual DNA in BLA reviews for monoclonal antibodies and recombinant proteins

### Key takeaways

- FDA treats host cell protein (HCP) and residual host cell DNA as process-related impurities controlled through product- and process-specific assays and acceptance criteria. No single numerical limit applies to all therapeutic proteins [86][87].
- In the BLA reviews examined, a recurring CMC question is HCP assay suitability, especially whether the anti-HCP antiserum covers the HCPs of the actual production cell line. Coverage is shown by comparing a sensitively stained 2D SDS-PAGE with a western blot probed with the assay antiserum [106][107][108].
- When coverage is incomplete, FDA has often accepted the existing assay at approval and required a postmarketing commitment (PMC) to develop a more sensitive, process-specific HCP assay. Examples include Keytruda, Opdivo, Unituxin, Tepezza and Gamifant [35][37][40][45][42].
- For residual DNA, the reviews examined mostly show qPCR results below detection or quantitation limits. Validated clearance can support removing DNA testing from lot release, as FDA accepted for Skyrizi [206].
- For biosimilars, FDA's current position is that HCP and DNA profiles do not need to match the reference product. They are evaluated through process controls and a risk-based assessment, including immunogenicity risk [91][157][164].

### Regulatory framework reviewers apply

The BLA review findings below follow from a small set of guidance documents.

**ICH Q6B.** Process-related impurities should be minimized through a well-controlled manufacturing process. Acceptance criteria are set individually or collectively as appropriate, based on data from clinical, preclinical and manufacturing-consistency lots. In some circumstances, a selected impurity may not need an acceptance criterion [86][87]. Q6B generally calls for a sensitive HCP immunoassay that detects a wide range of proteins. The assay's polyclonal antibody is raised against a production-cell preparation that lacks the product-coding gene. Host cell DNA can be measured directly in the product, and demonstrated clearance of HCP and nucleic acids (for example, by laboratory-scale spiking studies) can sometimes remove the need for acceptance criteria [88].

**CMC submission guidance for recombinant DNA-derived products and monoclonal antibodies.** The guidance asks for purification-validation documentation showing adequate removal of residual host proteins and DNA, where appropriate [89].

**Points to Consider in the Manufacture and Testing of Monoclonal Antibody Products for Human Use.** Lot-to-lot DNA testing before excipient addition is recommended unless a properly conducted DNA-clearance study substitutes for it. Final-product DNA should be as low as possible. The document suggests no more than 100 pg cellular DNA per dose whenever possible, using a method sensitive to 10 pg. It also calls for tests to detect and quantify HCP [90]. The 100 pg/dose value is a 1997 suggested target, not a universal regulatory limit that reviewers apply across products [90].

**Immunogenicity Assessment for Therapeutic Protein Products.** Host-cell-related impurities, including proteins and nucleic acids, can enhance immune responses. Even trace levels may matter, so assays should be sensitive enough and tailored to the relevant cell substrate [92]. The comparability protocols guidance likewise expects assessment of potentially immunogenic impurities such as HCP when a manufacturing change is made to a biological-source product [93].

**Biosimilar comparative analytical assessment guidance.** HCP and host cell DNA in the proposed biosimilar should be evaluated, but their profiles are not expected to match the reference product. They are generally not part of the comparative analytical assessment. Because HCP immunoassay results depend on the reagents and the cell substrate, the assays should be validated using the proposed product's cell substrate, with orthogonal methods supporting accuracy and sensitivity [91].

### HCP assay suitability: the core review issue

#### What FDA asks applicants to show

Across BLA reviews, FDA considered an HCP ELISA suitable only when the antiserum's coverage of relevant production-cell or process HCPs was demonstrated, together with adequate sensitivity and qualification or validation. Reviewers asked applicants to compare a sensitively stained two-dimensional SDS-PAGE HCP pattern with a western blot probed with the assay antiserum, and to estimate the percentage of potential HCPs the assay recognizes. A similarly sensitive and discriminating method could be used instead. One-dimensional gels alone were considered insufficient [106][107][108].

#### Product-specific findings

| Product | Expression context | FDA finding or request |
|---|---|---|
| Yervoy (ipilimumab) | mAb | Requested the HCP assay validation report and evidence that the antibody detects most potential process HCPs, using a sensitive gel/blot comparison or an equivalent method [108][111]. FDA also asked for clarification of CHO protein as a process-related impurity [2]. |
| Adcetris (brentuximab vedotin) | ADC | Requested qualification of the anti-HCP antiserum by sensitive-stain 2D SDS-PAGE compared with western blot, or a similarly sensitive assay [108][111]. |
| Opdivo (nivolumab) | mAb | Filing with the current assay might be acceptable if clinical-development data supported it. FDA expected a better-coverage assay to be developed and implemented after licensure, and asked that available information on it be included in the BLA [112]. |
| Trazimera (trastuzumab-qyyp) | Biosimilar mAb | Reviewers found the ELISA antibodies' overall coverage poor and the evidence insufficient to support the assay. They requested more data on coverage of HCPs specific to the production cell line [110]. |
| Inflectra (infliximab-dyyb) | Biosimilar mAb (Sp2/0) | FDA requested assay and antiserum descriptions, qualification and comparability methods, coverage and sensitivity data relative to the original assay, and 2D-gel/western-blot coverage data. FDA warned that commercial kits are usually insensitive to product-specific HCPs [109]. |
| Releuko (filgrastim-ayow) | Biosimilar recombinant protein | Changes to commercial-kit antibodies or other critical reagents could alter ELISA performance. FDA requested reagent control and requalification of new kit lots, including 2D SDS-PAGE/western blot coverage. FDA identified an in-house qualified antiserum as the best approach [115]. |
| Myalept (metreleptin) | *E. coli* | The commercial ELISA's claimed 74% antigen-pool coverage was not supported by data. Inspection data suggested inadequate coverage of the actual production cell line. The assay appeared adequate in routine operation, but reviewers were unsure whether it would detect increased HCP after a deviation [113]. |
| Tzield (teplizumab-mzwv) | mAb | The existing assay was acceptable for drug substance release. FDA sought product-specific HCP antibodies to ensure complete coverage and required a PMC [114]. |

Two themes stand out. First, FDA does not accept generic or commercial-kit ELISAs by default. Applicants must show coverage for the specific cell line and process, and must control critical reagents across kit lots [109][115]. Second, reviewers separate "adequate for routine release" from "able to detect a process excursion." Myalept is the clearest example: an assay can pass routine lots and still fail to flag an increase in HCP during a deviation [113].

#### Orthogonal methods

In the BLA review passages examined, FDA's coverage checks relied on gel/blot comparisons or similarly sensitive alternatives. These passages did not show reviewers requesting mass-spectrometry identification of individual HCPs or naming specific high-risk HCPs such as polysorbate-degrading lipases [209][210][211]. The biosimilar guidance does call for orthogonal methods to support HCP immunoassay accuracy and sensitivity [91]. The absence of such requests in these passages should not be read as FDA practice; current expectations, including USP <1132> and orthogonal MS characterization of high-risk HCPs, may not be reflected in the review text examined.

### Postmarketing commitments on HCP assays and limits

When coverage or sensitivity is not fully established at approval, FDA has repeatedly used PMCs instead of delaying approval. These commitments follow a consistent template:

| Product | Commitment |
|---|---|
| Keytruda (pembrolizumab) | Develop and validate a more sensitive, process-specific HCP assay with broader detection. Implement it for drug substance release and submit the procedure, validation report, proposed acceptance criterion and supporting data [35]. Separate PMCs require re-evaluation of drug substance and drug product specifications after 30 commercial-scale lots [36]. |
| Opdivo (nivolumab) | A parallel process-specific HCP assay commitment [37], with specification re-evaluation after 30 lots [38][39]. |
| Unituxin (dinutuximab) | Develop a process-specific assay with better sensitivity and broader coverage. Evaluate antiserum coverage by 2D SDS-PAGE and western blot, and submit the procedure, validation, gel/blot reproductions, coverage analysis and proposed acceptance criterion in a prior-approval supplement [40][107]. A separate PMC requires specification reassessment [41]. |
| Gamifant (emapalumab-lzsg) | Complete a more sensitive HCP assay, test all clinical, PPQ and commercial drug substance lots, then re-evaluate the HCP release acceptance criterion with statistical analysis [42]. Specifications are re-evaluated after 12 additional commercial lots [43]. |
| Tepezza (teprotumumab-trbw) | Develop, validate and implement a more sensitive, product-specific HCP assay. Submit it as a CBE-30 supplement [45]. |
| Ontruzant (trastuzumab-dttb) | Perform a qualification study using production material to confirm the assay detects product-specific HCP in drug substance [44]. |
| Tzield (teplizumab-mzwv) | Confirm current HCP assay suitability, defined by HCP coverage [46]. |
| Margenza (margetuximab-cmkb) | Include residual HCP in a postmarketing reassessment of drug substance specifications, either tightening or supporting the existing criterion [192]. |
| Xiaflex (collagenase *C. histolyticum*) | Demonstrate the feasibility of an immune-based HCP assay and propose a path forward [34]. |

The pattern shows that the HCP acceptance criterion depends on the assay. Gamifant illustrates this most directly: FDA tied re-evaluation of the HCP release limit to retesting historical lots with the improved assay [42]. Numerical HCP acceptance criteria (ng/mg or ppm) were generally not stated or were redacted in the review text examined [138][191].

### Residual host cell DNA: limits, assays and clearance

Residual DNA drew fewer review comments than HCP. Most findings in the reviews concern qPCR results at or below assay limits:

- **Kanjinti (trastuzumab-anns):** qPCR on 22 drug substance lots and three lots each of US-licensed and EU-approved Herceptin found DNA below the 0.2 pg/mg detection limit in all three products. The data supported similarity for this attribute [50]. The 0.2 pg/mg figure is a detection limit, not a release limit [50].
- **Mvasi (bevacizumab-awwb):** qPCR results were reported as below 1 pg/mg, with two EU-Avastin lots below 2 pg/mg. The reviewer found residual DNA levels similar across the three products [204][205].
- **Herzuma (trastuzumab-pkrb):** qPCR found DNA below the detection limit in every tested biosimilar and reference lot [51].
- **Nivestym (filgrastim-aafi):** DNA results by qPCR were below LOQ for both the biosimilar and US-licensed Neupogen lots. HCP by ELISA was below or near the 0.5 ng/mL LOQ. The reviewer judged host-cell impurities to be a low product-quality risk [186][176][162].
- **Myxredlin (insulin human) and Rylaze (crisantaspase):** Drug substance specifications include a host-cell DNA test (Myxredlin's limit is expressed per 3.5 mg), but the numerical values are redacted [207][208].

#### Clearance-based removal from release testing

Consistent with Q6B and the monoclonal antibody Points to Consider [88][90], FDA accepted demonstrated clearance as a basis to remove residual DNA testing from lot release for Skyrizi (risankizumab-rzaa) [206]. Pre-submission correspondence shows FDA's conditions for this approach:

- **Cyramza (ramucirumab):** Clearance of process-related impurities to below detection or quantitation limits could potentially justify removing them from the drug substance specification. FDA reserved its decision until BLA review and asked for the risk assessment, evidence that the small-scale model represents the commercial process, and qualification of the HCP assay [57].
- **Ajovy (fremanezumab-vfrm):** FDA asked for a risk assessment estimating the process's impurity-removal capability and theoretical residual levels. It said theoretical clearance might support a specification justification [58].

The Cyramza correspondence shows that HCP assay qualification is a prerequisite for clearance claims: FDA cannot rely on clearance data generated with an assay whose coverage has not been established [57].

### Biosimilars: risk-based assessment, not matching

FDA's biosimilar reviews increasingly reflect the guidance position that process-related impurities need not match the reference product [91]:

- **Nyvepria (pegfilgrastim-apgf):** FDA considered direct HCP/DNA comparison inappropriate because the manufacturing processes differ. It accepted commercial process controls, with HCP and residual DNA results below the reported limits across roughly 30 lots [157].
- **Rezvoglar, Semglee (insulin glargine) and Stoboclo/Osenvelt (denosumab-bmwo):** Reviewers took the same approach and assessed HCP and DNA through commercial process controls [158][159][160][161].
- **Ziextenzo (pegfilgrastim-bmez):** FDA recommended side-by-side assessment of process-related impurities without expecting them to match. Different or higher impurity levels would require a risk assessment and possibly more studies, because of potential effects on safety, purity and potency [164].
- **Udenyca (pegfilgrastim-cbqv):** 2D gels showed minor HCP differences from Neulasta. The reviewer accepted the HCP risk assessment, which found very little risk, but noted residual uncertainty given Udenyca's higher incidence of immunogenicity. The review did not establish that the HCP differences caused it [126].

Earlier trastuzumab and bevacizumab biosimilars (Kanjinti, Mvasi) did report comparative DNA and HCP data as supportive tier 3 similarity assessments [187][188][205]. Later reviews more often rely on process control instead.

### Non-CHO expression systems and immunogenicity

For microbial and yeast-expressed proteins, reviewers linked HCP control directly to immunogenicity:

- **Myalept (metreleptin, *E. coli*):** Reviewers noted that HCP can act as an adjuvant, and that neutralizing antibodies to metreleptin have been associated with loss of efficacy or of endogenous leptin activity. Even so, FDA allowed the assay work to continue after approval, citing the controlled process and the seriousness and rarity of the disease [144][145].
- **Semglee (insulin glargine, yeast):** The immunogenicity reviewer found the anti-yeast-HCP antibody assay adequately validated. The proportions of anti-HCP antibody-positive patients were comparable between Semglee and Lantus [146].
- **Qwo (collagenase clostridium histolyticum-aaes):** FDA's quality risk table classified production-cell HCP as a safety and immunogenicity risk, and production-cell DNA as a safety risk [147].
- **Somavert (pegvisomant):** Reviewers evaluated the specificity and detection limit of the residual *E. coli* protein assay [212].

### Practical implications for BLA sponsors

Based on these reviews, sponsors should expect FDA to focus on the following:

1. **Coverage data for the HCP assay.** Provide 2D SDS-PAGE/western blot (or an equivalent sensitive method) coverage data for the actual production cell line. A commercial kit's claimed coverage is not enough [108][113][109].
2. **Readiness for a PMC on the HCP assay.** If a platform or commercial assay has limited coverage, FDA may accept it at approval and require a process-specific assay with re-evaluation of the acceptance criterion after licensure [35][42][45].
3. **Critical reagent control.** Requalify coverage when antiserum or kit lots change [115].
4. **Clearance claims built on qualified assays and representative scale-down models.** These are the basis for removing DNA or HCP from release testing [57][206].
5. **A risk-based justification for differences in biosimilar programs.** Do not try to match reference-product HCP and DNA levels; justify any difference by risk, with attention to immunogenicity [91][164][126].
6. **Clinically and process-based acceptance criteria.** Base limits on clinical and manufacturing-consistency lots, and expect re-evaluation after a defined number of commercial lots [86][36][43].

## Sources

Numbered to match the [N] markers in the text.

- [2] [YERVOY · Bristol Myers Squibb (BLA 125377)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2011/125377Orig1s000Admincorres.pdf) — Drugs@FDA, p. 121
- [34] [XIAFLEX · Auxilium Pharms (BLA 125338)](https://www.accessdata.fda.gov/drugsatfda_docs/appletter/2010/125338s000ltr.pdf) — Drugs@FDA, p. 5
- [35] [KEYTRUDA · Merck Sharp Dohme (BLA 125514)](https://www.accessdata.fda.gov/drugsatfda_docs/appletter/2014/125514Orig1s000ltr.pdf) — Drugs@FDA, p. 4
- [36] [KEYTRUDA · Merck Sharp Dohme (BLA 125514)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2014/125514Orig1s000SumR.pdf) — Drugs@FDA, p. 23
- [37] [OPDIVO · Bristol Myers Squibb (BLA 125554)](https://www.accessdata.fda.gov/drugsatfda_docs/appletter/2014/125554Orig1s000ltr.pdf) — Drugs@FDA, p. 4
- [38] [OPDIVO · Bristol Myers Squibb (BLA 125554)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2014/125554Orig1s000Approv.pdf) — Drugs@FDA, p. 7
- [39] [OPDIVO · Bristol Myers Squibb (BLA 125554)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2014/125554Orig1s000Approv.pdf) — Drugs@FDA, p. 7
- [40] [UNITUXIN · United Therap (BLA 125516)](https://www.accessdata.fda.gov/drugsatfda_docs/appletter/2015/125516Orig1s000ltr.pdf) — Drugs@FDA, p. 7
- [41] [UNITUXIN · United Therap (BLA 125516)](https://www.accessdata.fda.gov/drugsatfda_docs/appletter/2015/125516Orig1s000ltr.pdf) — Drugs@FDA, p. 7
- [42] [GAMIFANT · Novimmune S.A. (BLA 761107)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2018/761107Orig1s000MultidisciplineR.pdf) — Drugs@FDA, p. 116
- [43] [GAMIFANT · Novimmune S.A. (BLA 761107)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2018/761107Orig1s000MultidisciplineR.pdf) — Drugs@FDA, p. 116
- [44] [ONTRUZANT · Samsung Bioepis Co Ltd (BLA 761100)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2019/761100Orig1s000Approv.pdf) — Drugs@FDA, p. 9
- [45] [TEPEZZA · Horizon Therapeutics Ireland (BLA 761143)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2021/761143Orig1s000SumR.pdf) — Drugs@FDA, p. 10
- [46] [TZIELD · Provention Bio Inc (BLA 761183)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2023/761183Orig1s000Approv.pdf) — Drugs@FDA, p. 10
- [50] [KANJINTI · Amgen Inc (BLA 761073)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2019/761073Orig1s000ChemR.pdf) — Drugs@FDA, p. 159
- [51] [HERZUMA · Celltrion Inc (BLA 761091)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2018/761091Orig1s000ChemR.pdf) — Drugs@FDA, p. 52
- [57] [CYRAMZA · Eli Lilly And Co (BLA 125477)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2014/125477Orig1s000AdminCorres.pdf) — Drugs@FDA, p. 132
- [58] [AJOVY · Teva Pharms Usa (BLA 761089)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2018/761089Orig1s000AdminCorres.pdf) — Drugs@FDA, p. 60
- [86] [Q6B Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products](https://www.fda.gov/media/71510/download) — FDA Guidance, p. 15
- [87] [Q6B Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products](https://www.fda.gov/media/71510/download) — FDA Guidance, p. 9
- [88] [Q6B Specifications: Test Procedures and Acceptance Criteria for Biotechnological/Biological Products](https://www.fda.gov/media/71510/download) — FDA Guidance, p. 23
- [89] [Guidance for Industry for the Submission of Chemistry, Manufacturing, and Controls Information for a Therapeutic Recomb…](https://www.fda.gov/media/77528/download) — FDA Guidance, p. 22
- [90] [Points to Consider in the Manufacture and Testing of Monoclonal Antibody Products for Human Use](https://www.fda.gov/media/76798/download) — FDA Guidance, p. 21
- [91] [Development of Therapeutic Protein Biosimilars: Comparative Analytical Assessment and Other Quality-Related Considerati…](https://www.fda.gov/media/159261/download) — FDA Guidance, p. 16
- [92] [Immunogenicity Assessment for Therapeutic Protein Products](https://www.fda.gov/media/85017/download) — FDA Guidance, p. 21
- [93] [Comparability Protocols for Postapproval Changes to the Chemistry, Manufacturing, and Controls Information in an NDA, A…](https://www.fda.gov/media/162263/download) — FDA Guidance, p. 27
- [106] [INFLECTRA · Celltrion Inc (BLA 125544)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2016/125544Orig1s000AdminCorresedt.pdf) — Drugs@FDA, p. 325
- [107] [UNITUXIN · United Therap (BLA 125516)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2015/125516Orig1s000Admincorres.pdf) — Drugs@FDA, p. 110
- [108] [ADCETRIS · Seattle Genetics (BLA 125388)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2011/125388Orig1s000AdminCorres.pdf) — Drugs@FDA, p. 95
- [109] [INFLECTRA · Celltrion Inc (BLA 125544)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2016/125544Orig1s000AdminCorresedt.pdf) — Drugs@FDA, p. 325
- [110] [TRAZIMERA · Pfizer Inc (BLA 761081)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2019/761081Orig1s000OtherActionLtrs.pdf) — Drugs@FDA, p. 8
- [111] [YERVOY · Bristol Myers Squibb (BLA 125377)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2011/125377Orig1s000Admincorres.pdf) — Drugs@FDA, p. 206
- [112] [OPDIVO · Bristol Myers Squibb (BLA 125527)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2015/125527Orig1s000Admincorres.pdf) — Drugs@FDA, p. 69
- [113] [MYALEPT · Chiesi Farmaceutici Spa (BLA 125390)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2014/125390Orig1s000OtherR.pdf) — Drugs@FDA, p. 24
- [114] [TZIELD · Provention Bio Inc (BLA 761183)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2023/761183Orig1s000CrossR.pdf) — Drugs@FDA, p. 21
- [115] [RELEUKO · Kashiv Biosciences Llc (BLA 761082)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2022/761082Orig1s000OtherActionLtrs.pdf) — Drugs@FDA, p. 49
- [126] [UDENYCA · Coherus Biosciences Inc (BLA 761039)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2018/761039Orig1s000ChemR.pdf) — Drugs@FDA, p. 276
- [138] [MARGENZA · Tersera Therapeutics Llc (BLA 761150)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2020/761150Orig1s000ChemR.pdf) — Drugs@FDA, p. 13
- [144] [MYALEPT · Chiesi Farmaceutici Spa (BLA 125390)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2014/125390Orig1s000OtherR.pdf) — Drugs@FDA, p. 24
- [145] [MYALEPT · Chiesi Farmaceutici Spa (BLA 125390)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2014/125390Orig1s000OtherR.pdf) — Drugs@FDA, p. 24
- [146] [SEMGLEE · Mylan Pharms Inc (BLA 210605)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2020/210605Orig1s000MedR.pdf) — Drugs@FDA, p. 91
- [147] [QWO · Endo Global Aesthetics Ltd (BLA 761146)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2020/761146Orig1s000ChemR.pdf) — Drugs@FDA, p. 9
- [157] [NYVEPRIA · Hospira Inc (BLA 761111)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2020/761111Orig1s000ChemR.pdf) — Drugs@FDA, p. 55
- [158] [REZVOGLAR · Eli Lilly Co (BLA 761215)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2022/761215Orig1s000ChemR.pdf) — Drugs@FDA, p. 34
- [159] [REZVOGLAR · Eli Lilly Co (BLA 761215)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2022/761215Orig1s000MultidisciplineR.pdf) — Drugs@FDA, p. 25
- [160] [SEMGLEE · Mylan Pharms Inc (BLA 761201)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2021/761201Orig1s000ChemR.pdf) — Drugs@FDA, p. 132
- [161] [Stoboclo, Osenvelt · Celltrion Inc (BLA 761404)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2025/761404Orig1s000ChemR.pdf) — Drugs@FDA, p. 41
- [162] [NIVESTYM · Hospira Inc (BLA 761080)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2018/761080Orig1s000ChemR.pdf) — Drugs@FDA, p. 115
- [164] [ZIEXTENZO · Sandoz Inc (BLA 761045)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2019/761045Orig1s000AdminCorres.pdf) — Drugs@FDA, p. 6
- [176] [NIVESTYM · Hospira Inc (BLA 761080)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2018/761080Orig1s000ChemR.pdf) — Drugs@FDA, p. 137
- [186] [NIVESTYM · Hospira Inc (BLA 761080)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2018/761080Orig1s000ChemR.pdf) — Drugs@FDA, p. 136
- [187] [KANJINTI · Amgen Inc (BLA 761073)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2019/761073Orig1s000ChemR.pdf) — Drugs@FDA, p. 71
- [188] [KANJINTI · Amgen Inc (BLA 761073)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2019/761073Orig1s000ChemR.pdf) — Drugs@FDA, p. 71
- [191] [TZIELD · Provention Bio Inc (BLA 761183)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2023/761183Orig1s000ChemR.pdf) — Drugs@FDA, p. 27
- [192] [MARGENZA · Tersera Therapeutics Llc (BLA 761150)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2020/761150Orig1s000ChemR.pdf) — Drugs@FDA, p. 13
- [204] [MVASI · Amgen Inc (BLA 761028)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2017/761028Orig1s000ChemR.pdf) — Drugs@FDA, p. 114
- [205] [MVASI · Amgen Inc (BLA 761028)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2017/761028Orig1s000ChemR.pdf) — Drugs@FDA, p. 114
- [206] [SKYRIZI · Abbvie Inc (BLA 761262)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2023/761262Orig1s000ChemR.pdf) — Drugs@FDA, p. 32
- [207] [MYXREDLIN · Baxter Hlthcare Corp (BLA 208157)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2019/208157Orig1s000PharmR.pdf) — Drugs@FDA, p. 62
- [208] [RYLAZE · Jazz Pharms (BLA 761179)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2021/761179Orig1s000ChemR.pdf) — Drugs@FDA, p. 10
- [209] [SAPHNELO · Astrazeneca Ab (BLA 761123)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2021/761123Orig1s000MultidisciplineR.pdf) — Drugs@FDA, p. 123
- [210] [ENFLONSIA · Merck Sharp Dohme (BLA 761432)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2025/761432Orig1s000IntegratedR.pdf) — Drugs@FDA, p. 181
- [211] [SOMAVERT · PHARMACIA (BLA 021106)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2003/21-106_Somavert_Admindocs_P2.pdf) — Drugs@FDA, p. 6
- [212] [SOMAVERT · PHARMACIA (BLA 021106)](https://www.accessdata.fda.gov/drugsatfda_docs/nda/2003/21-106_Somavert_Admindocs_P2.pdf) — Drugs@FDA, p. 6

---

Rhizome AI researched and wrote this article from health-authority documents. Ask it your own regulatory question at https://rhizomeai.com. More articles: https://rhizomeai.com/articles.md. Guide for agents: https://rhizomeai.com/llms.txt